Late tibial interference screw extrusion following anterior cruciate ligament reconstruction: A case report

被引:2
|
作者
Milam, Rachel J. [1 ]
Drayer, Nicholas J. [2 ]
Wallace, Christopher S. [1 ]
Kang, Daniel G. [1 ]
Masini, Brendan D. [1 ]
机构
[1] Madigan Army Med Ctr, Orthopaed Surg, Joint Base Lewis McChord, WA 98431 USA
[2] Winn Army Community Hosp, Dept Orthopaed, Ft Stewart, GA USA
关键词
CLINICAL-EXPERIENCE; MIGRATION; IMPLANTS;
D O I
10.52965/001c.37078
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Interference screws are used as back-up fixation in anterior cruciate ligament reconstructions. Historically these were composed of metal, but recently surgeons have switched to using bioabsorbable screws as they cause less symptoms and are biomedically advantageous. Usually these screws are absorbed by the body within one to two years after surgery. Case Presentation A 32-year-old male presented with aseptic extrusion of his intact tibial bioabsorbable interference screw eight years following successful anterior cruciate ligament reconstruction. Management and Outcomes Patient underwent laboratory evaluation and magnetic resonance imaging to rule out infection as an underlying cause. He went on to heal the wound without complication. Conclusion Late aseptic extrusion of tibial interference screw can occur; however, infectious etiologies should be carefully ruled out.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A modified technique for tibial interference screw fixation of hamstring anterior cruciate ligament grafts
    Bellemans, J
    Eid, T
    Fabry, G
    ARTHROSCOPY, 1999, 15 (06): : 669 - 671
  • [22] Femoral interference screw placement through the tibial tunnel: A radiographic evaluation of interference screw divergence angles after endoscopic anterior cruciate ligament reconstruction
    Brodie, JT
    Torpey, BM
    Donald, GD
    Bade, HA
    ARTHROSCOPY, 1996, 12 (04): : 435 - 440
  • [23] The Development and Biomechanical Analysis of an Allograft Interference Screw for Anterior Cruciate Ligament Reconstruction
    Lifka, Sebastian
    Rehberger, Yannik
    Pastl, Klaus
    Rofner-Moretti, Alexander
    Reichkendler, Markus
    Baumgartner, Werner
    BIOENGINEERING-BASEL, 2023, 10 (10):
  • [24] Interference screw position and hamstring graft location for anterior cruciate ligament reconstruction
    Simonian, PT
    Sussmann, PS
    Baldini, TH
    Crockett, HC
    Wickiewicz, TL
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (05): : 459 - 464
  • [25] Does the position of interference screw in tibial tunnel effect anatomic orientation in single bundle anterior cruciate ligament reconstruction?
    Chernchujit, Bancha
    Agrawal, Sumit
    Sukhapradit, Bordee
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2020, 22 : 15 - 19
  • [26] Necrotising fasciitis following anterior cruciate ligament reconstruction. A case report
    Campion, J
    Allum, R
    KNEE, 2006, 13 (01): : 51 - 53
  • [27] Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect
    Thaunat, M
    Nourissat, G
    Gaudin, P
    Beaufils, P
    KNEE, 2006, 13 (03): : 241 - 243
  • [28] Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction
    Caborn, DNM
    Selby, JB
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01): : 102 - 105
  • [29] Tibial plateau fracture following allograft anterior cruciate ligament (ACL) reconstruction
    El-Hage, ZM
    Mohammed, A
    Griffiths, D
    Richardson, JB
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01): : 73 - 74
  • [30] Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction
    Baums, M. H.
    Zelle, B. A.
    Schultz, W.
    Ernstberger, T.
    Klinger, H. -M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (09) : 865 - 868