Late tibial interference screw extrusion following anterior cruciate ligament reconstruction: A case report

被引:2
|
作者
Milam, Rachel J. [1 ]
Drayer, Nicholas J. [2 ]
Wallace, Christopher S. [1 ]
Kang, Daniel G. [1 ]
Masini, Brendan D. [1 ]
机构
[1] Madigan Army Med Ctr, Orthopaed Surg, Joint Base Lewis McChord, WA 98431 USA
[2] Winn Army Community Hosp, Dept Orthopaed, Ft Stewart, GA USA
关键词
CLINICAL-EXPERIENCE; MIGRATION; IMPLANTS;
D O I
10.52965/001c.37078
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Interference screws are used as back-up fixation in anterior cruciate ligament reconstructions. Historically these were composed of metal, but recently surgeons have switched to using bioabsorbable screws as they cause less symptoms and are biomedically advantageous. Usually these screws are absorbed by the body within one to two years after surgery. Case Presentation A 32-year-old male presented with aseptic extrusion of his intact tibial bioabsorbable interference screw eight years following successful anterior cruciate ligament reconstruction. Management and Outcomes Patient underwent laboratory evaluation and magnetic resonance imaging to rule out infection as an underlying cause. He went on to heal the wound without complication. Conclusion Late aseptic extrusion of tibial interference screw can occur; however, infectious etiologies should be carefully ruled out.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Tibial interference-screw extrusion at the early stage after anterior cruciate ligament reconstruction: A case report
    Wen, Dan
    Guo, Dan
    ASIAN JOURNAL OF SURGERY, 2024, 47 (04) : 1800 - 1802
  • [2] TIBIAL INTERFERENCE SCREW REMOVAL FOLLOWING ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    KURZWEIL, PR
    FROGAMENI, AD
    JACKSON, DW
    ARTHROSCOPY, 1995, 11 (03): : 289 - 291
  • [3] Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction
    Sassmannshausen, G
    Caff, CF
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09):
  • [4] Rehabilitation of Tibial Plateau Fracture Following Anterior Cruciate Ligament Reconstruction: A Case Report
    Rabatsky, Ali
    Lockenour, John D.
    JOURNAL OF CHIROPRACTIC MEDICINE, 2018, 17 (01) : 63 - 67
  • [5] Extrusion of Tibial Tunnel Bioabsorbable Screw 15 Months After Anterior Cruciate Ligament Reconstruction
    Anakwenze, Okechukwu A.
    Kancherla, Vamsi
    Kelly, John D.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (12): : 1710 - 1713
  • [6] Clinical failure of tibial interference screw fixation after anterior cruciate ligament reconstruction - A report of two cases
    Cooper, DE
    Wilson, TW
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (05): : 693 - 697
  • [7] Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction
    Black, KP
    Saunders, MM
    Stube, KC
    Moulton, MJR
    Jacobs, CR
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (06): : 846 - 849
  • [8] Tibial Interference Screw Fixation in Anterior Cruciate Ligament Reconstruction With and Without Autograft Bone Augmentation
    Roy, Stuart
    Fernhout, Mark
    Stanley, Richard
    McGee, Margaret
    Carbone, Tania
    Field, John R.
    Dobson, Peter
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (07): : 949 - 956
  • [9] ARTHROSCOPIC PLACEMENT OF THE INTERFERENCE SCREW FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    CERULLO, G
    PUDDU, G
    ARTHROSCOPY, 1993, 9 (06): : 712 - 713
  • [10] Interference screw divergence in endoscopic anterior cruciate ligament reconstruction
    Dworsky, BD
    Jewell, BF
    Bach, BR
    ARTHROSCOPY, 1996, 12 (01): : 45 - 49