Validation and application of solid-phase chemiluminescent immunoassays for diagnosis of endocrine diseases in animals

被引:70
|
作者
Reimers, TJ
Salerno, VJ
Lamb, SV
机构
[1] Diagnostic Laboratory, College of Veterinary Medicine, Cornell University, Ithaca, NY
来源
关键词
automation; chemiluminescence; endocrinology; immunoassay; validation; veterinary medicine;
D O I
10.1007/BF00368462
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Significant progress has been made in the ability of veterinarians to diagnose endocrine diseases since introduction and development of the radioimmunoassay (RIA) in the 1960s. Alternatives to the radioactive label have been commercialised for human diagnostic applications. Because healthy animals have concentrations of several hormones in serum that are lower than in humans, these non-isotopic assays generally lack the sensitivity for measuring hormones in animals. However, the chemiluminescent enzyme immunoassay may provide this needed sensitivity. We validated the DPC-Cirrus Immulite(R) automated chemiluminescent immunoassay system for measurement of cortisol in dogs, cats and horses. Serial dilutions of serum inhibited binding of alkaline phosphatase-labelled cortisol in a manner that was parallel with inhibition produced by the stored master calibration curve. Six dogs were injected with adrenocorticotropin (ACTH; 2.2 IU/kg i.m.) and five dogs were injected with dexamethasone (0.015 mg/kg i.v.). Changes in cortisol concentrations measured with the Immulite(R) were as expected based on published results. Similar tests of biological specificity in other species yielded similar results. Accuracy of the Immulite(R) cortisol assay was evaluated by comparing cortisol concentrations in serum with concentrations obtained by a validated RIA. The regression equations were: y = 14.6 + 0.8x for dogs (n = 59, r(2) = 0.91), y = 13.5 + 0.9x for horses (n = 23, r(2) = 0.90), and y = 29.8 + 1.Ox for cats (n = 18, r(2) = 0.96), where y = Immulite(R) result (nmol/l) and x = RIA result (nmol/l). The regression equation for the canine urinary cortisol: creatinine ratio was y = 0.43 + 1.55x, where y = ratio calculated from Immulite(R) cortisol concentrations and x = ratio using RIA concentrations (n = 35, r(2) = 0.93). Initially, the lower limit of the reportable range by the Immulite(R) was 27.6 nmol/l, a value that was unacceptable for veterinary diagnostics. After consultation with DPC-Cirrus, we adjusted the lower limit to 1.4 nmol/l. Coefficients of variation for two canine, one feline, and two equine quality-control serum samples included in 73 consecutive Immulite(R) assays ranged from 0.29 (mean = 29.0 nmol/l) to 0.09 (mean = 261.6 nmol/l). We are using the Immulite(R) routinely for the diagnosis of adrenal disease in animals and have found it to provide diagnostically useful cortisol results for dexamethasone-suppression and ACTH-stimulation tests. Its diagnostic accuracy on single baseline samples is probably less than for the RIA, particularly at concentrations of cortisol less than 27.6 nmol/l.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
  • [31] THE ADSORPTIVE CHARACTERISTICS OF PROTEINS FOR POLYSTYRENE AND THEIR SIGNIFICANCE IN SOLID-PHASE IMMUNOASSAYS
    CANTARERO, LA
    BUTLER, JE
    OSBORNE, JW
    ANALYTICAL BIOCHEMISTRY, 1980, 105 (02) : 375 - 382
  • [32] Use of Polymer Micropillar Arrays as Templates for Solid-Phase Immunoassays
    Geissler, Matthias
    Ponton, Andre
    Nassif, Christina
    Malic, Lidija
    Turcotte, Karine
    Lukic, Ljuboje
    Morton, Keith J.
    Veres, Teodor
    ACS APPLIED POLYMER MATERIALS, 2022, 4 (08) : 5287 - 5297
  • [33] Detection of antinuclear antibodies by solid-phase immunoassays and immunofluorescence analysis
    Fenger, M
    Wiik, A
    Hoier-Madsen, M
    Lykkegaard, JJ
    Rozenfeld, T
    Hansen, MS
    Samsoe, BD
    Jacobsen, S
    CLINICAL CHEMISTRY, 2004, 50 (11) : 2141 - 2147
  • [34] RAPID DETECTION OF SALMONELLAE BY IMMUNOASSAYS WITH TITANOUS HYDROXIDE AS THE SOLID-PHASE
    IBRAHIM, GF
    LYONS, MJ
    WALKER, RA
    FLEET, GH
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (03) : 670 - 675
  • [35] OPTIMIZING THE SOLID-PHASE IMMUNOFILTRATION ASSAY - A RAPID ALTERNATIVE TO IMMUNOASSAYS
    IJSSELMUIDEN, OE
    HERBRINK, P
    MEDDENS, MJM
    TANK, B
    STOLZ, E
    VANEIJK, RVW
    JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 119 (01) : 35 - 43
  • [36] DEVELOPMENT OF SOLID-PHASE CHEMI-LUMINESCENCE IMMUNOASSAYS FOR STEROIDS
    KOHEN, F
    KIM, JB
    LINDNER, HR
    COLLINS, WP
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 736 - 736
  • [37] SOLID-PHASE RADIOIMMUNOASSAY FOR PROGESTERONE AND ITS APPLICATION TO PREGNANCY DIAGNOSIS IN THE COW
    GOWAN, EW
    ETCHES, RJ
    THERIOGENOLOGY, 1979, 12 (06) : 327 - 343
  • [38] Development and validation of two solid-phase enzyme immunoassays (ELISA) for quantitation of human epidermal growth factors (hEGFs)
    Sizemore, N
    Dudeck, RC
    Barksdale, CM
    Nordblom, GD
    Mueller, WT
    McConnell, P
    Wright, DS
    Guglietta, A
    Kuo, BS
    PHARMACEUTICAL RESEARCH, 1996, 13 (07) : 1088 - 1094
  • [39] SOLID-PHASE CHEMILUMINESCENT REAGENT FOR DETERMINATION OF VANADIUM(IV) BY FLOW METHODS
    SUKHAN, VV
    ZAPOROZHETS, OA
    LIPKOVSKAYA, NA
    POGASII, LB
    CHUIKO, AA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (07) : 632 - 635
  • [40] Universal Access to Protease Chemiluminescent Probes through Solid-Phase Synthesis
    Ponomariov, Maria
    Shabat, Doron
    Green, Ori
    BIOCONJUGATE CHEMISTRY, 2021, 32 (10) : 2134 - 2140