Development of a high-performance liquid chromatography carbon column based method for the fractionation of dioxin-like polychlorinated biphenyls

被引:19
|
作者
Lundgren, K [1 ]
van Bavel, B
Tysklind, M
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
[2] Univ Orebro, MTM Res Ctr, SE-70182 Orebro, Sweden
关键词
fish; oils; food analysis; polychlorinated biphenyls; clophen A50;
D O I
10.1016/S0021-9673(02)00443-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method to separate polychlorinated biphenyls (PCBs) by using high-performance liquid chromatography (HPLC) was developed. The HPLC column was packed with Amoco PX-21 activated carbon dispersed on octadecylsilane (ODS). The separation was carried out by gradient elution with n-hexane-dichloromethane and toluene in the forward direction followed by reversed elution with toluene. The results show that this HPLC method is useful for the separation of PCBs according to the number of substituted ortho chlorine atoms attached to the biphenyl structure. Average recoveries for a number of individual di-ortho PCBs, mono-ortho PCBs, and non-ortho PCBs in three selected elution windows were 97, 92, and 96%, respectively. Clophen A50, a herring sample, and a cod liver oil sample were fractionated on the column and the analytical results are compared with data from the literature. The method presented here is useful for quantitative separations of mono-ortho PCBs as well as non-ortho PCBs which have been assigned toxic equivalency factors by the World Health Organisation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:79 / 93
页数:15
相关论文
共 50 条
  • [31] HIGH-PERFORMANCE LIQUID COLUMN CHROMATOGRAPHY OF FENOPROFEN IN SERUM
    MICELI, JN
    RYAN, DM
    DONE, AK
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (02): : 250 - 254
  • [32] Rapid Method for Determination of Dioxin-Like Polychlorinated Biphenyls and Other Congeners in Marine Sediments Using Sonic Extraction and Photodiode Array Detection
    J. Buzitis
    G. M. Ylitalo
    M. M. Krahn
    Archives of Environmental Contamination and Toxicology, 2006, 51 : 337 - 346
  • [33] Rapid method for determination of dioxin-like polychlorinated biphenyls and other congeners in marine sediments using sonic extraction and photodiode array detection
    Buzitis, J.
    Ylitalo, G. M.
    Krahn, M. M.
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2006, 51 (03) : 337 - 346
  • [34] SAMPLE REMAINING IN AN ODS COLUMN AFTER COMPOSITIONAL FRACTIONATION OF COPOLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TERAMACHI, S
    HASEGAWA, A
    MATSUMOTO, T
    JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2): : 429 - 433
  • [35] Suppressive effect of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls transfer from feed to eggs of laying hens by activated carbon as feed additive
    Fujita, Hiroyuki
    Honda, Katsuhisa
    Iwakiri, Ryoji
    Guruge, Keerthi S.
    Yamanaka, Noriko
    Tanimura, Nobuhiko
    CHEMOSPHERE, 2012, 88 (07) : 820 - 827
  • [36] An automated HPLC method for the fractionation of polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins, and polychlorinated dibenzofurans in fish tissue on a porous graphitic carbon column
    Echols, K
    Gale, R
    Tillitt, D
    Schwartz, T
    OLaughlin, J
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1997, 16 (08) : 1590 - 1597
  • [37] FRACTIONATION OF AORTA GLYCOSAMINOGLYCANS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LEE, YJ
    RADHAKRISHNAMURTHY, B
    DALFERES, ER
    BERENSON, GS
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 : 275 - 279
  • [38] Use of high-performance liquid chromatography for the estimation of polychlorinated biphenyls and p,p-DDE residues in marine mammals
    Hayteas, DL
    Duffield, DA
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 705 (02): : 362 - 366
  • [39] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF OLIGOSACCHARIDE ALDITOLS AND GLYCOPEPTIDES ON A GRAPHITIZED CARBON COLUMN
    DAVIES, M
    SMITH, KD
    HARBIN, AM
    HOUNSELL, EF
    JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2): : 125 - 131
  • [40] COPOLYMER FRACTIONATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GLOCKNER, G
    VANDENBERG, JHM
    JOURNAL OF CHROMATOGRAPHY, 1987, 384 : 135 - 144