Study on Spread of Fire Overflow on Building Facades with Insulation Materials

被引:0
|
作者
Li, Yanfeng [1 ]
Xu, Congcong [1 ]
Xing, Xuefei [1 ]
Zhang, Jin [2 ]
Hu, Cheng [2 ]
机构
[1] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[2] Beijing Municipal Inst Labor Protect, Beijing 10054, Peoples R China
来源
PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4 | 2013年 / 405-408卷
关键词
Building insulation; Facade opening; FDS; Fire overflow;
D O I
10.4028/www.scientific.net/AMM.405-408.2438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fire overflow on exterior wall with thermal insulation system has been studied by numerical simulation. The spread laws of fire overflow are analyzed through the temperature distribution near the window. The computational results are compared with those of test in the Exterior Insulation Fire Barrier Technical Guidelines (EIFBTG). It has been found that the calculated maximum temperature points is closed to the test on the first floor, the first ceiling, and the points near the above two windows. However, there are differences between two kinds of results above two floors and ceilings, and the points near the first window. It has also shown that when the HEIR is 7.5KW, the scope of damage of exterior thermal insulation layer is about 15 square meters near the window. The research would provide reference for fire protection design of exterior wall thermal insulation in the high-rise buildings.
引用
收藏
页码:2438 / +
页数:2
相关论文
共 50 条
  • [21] Switchable Thermal Insulation for increasing energy efficiency of building facades
    Roemer, Constantin
    Weinlaeder, Helmut
    Weismann, Stephan
    Vidi, Stephan
    Wachtel, Johannes
    PROCEEDINGS OF THE 11TH ISES EUROSUN 2016 CONFERENCE, 2017, : 174 - 179
  • [22] Performance of modern building facades in fire: a comprehensive review
    Nguyen, Kate T. Q.
    Weerasinghe, Pasindu
    Mendis, Priyan
    Tuan Ngo
    Barnett, Jonathan
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2016, 16 (01): : 69 - 86
  • [23] FIRE SPREAD IN CONCEALED FOAMED PLASTIC INSULATION
    TAYLOR, W
    FIRE TECHNOLOGY, 1983, 19 (03) : 192 - 203
  • [24] REDUCING SPREAD OF FIRE BY PVC CABLE INSULATION
    PHILBRICK, SE
    ELECTRICAL REVIEW, 1972, 190 (11): : 363 - +
  • [25] A Study of Thermal Modeling for Fire Spread Mechanism in Residential Building
    Ahn, Chan-Sol
    Kim, Heung-Youl
    You, Yong-Ho
    Kim, Hyung-Jun
    TRENDS IN BUILDING MATERIALS RESEARCH, PTS 1 AND 2, 2012, 450-451 : 454 - +
  • [26] Numerical Analysis on the Effect of Thermal Insulation of Closure on Fire Smoke Spread Rate in Building's Corridor
    Peng, Xuanwei
    APPLIED SCIENCE, MATERIALS SCIENCE AND INFORMATION TECHNOLOGIES IN INDUSTRY, 2014, 513-517 : 2635 - 2638
  • [27] Thermal and sound insulation performance assessment of vacuum insulated composite insulation panels for building facades
    O'Flaherty, Fin
    Alam, Mahmood
    ADVANCES IN BUILDING ENERGY RESEARCH, 2021, 15 (03) : 270 - 290
  • [28] Experimental study on fallout behaviour of tempered glass facades with different frame insulation conditions in an enclosure fire
    Wang, Yu
    Sun, Jinhua
    He, Linghui
    Wang, Qingsong
    Rush, David
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2019, 37 (03) : 3889 - 3898
  • [29] THERMAL INSULATION OF BUILDING MATERIALS
    CRAWLEY, CB
    AMERICAN JOURNAL OF PHYSICS, 1948, 16 (02) : 118 - 119
  • [30] Dynamic modeling of fire spread in building
    Cheng, Hao
    Hadjisophocleous, George V.
    FIRE SAFETY JOURNAL, 2011, 46 (04) : 211 - 224