Analysis of harmonic characteristics based on improved double-LCC compensation network structure

被引:4
|
作者
Sun, Shuyao [1 ]
Liu, Zhizhen [1 ]
Hou, Yanjin [1 ,2 ]
Li, Xianglin [1 ]
Xie, Yuxin [1 ]
Zhai, Huiqiang [3 ]
Wei, Xiaozhao [3 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jingshi Rd 17923, Jinan 250061, Peoples R China
[2] Qilu Univ Technol, Energy Res Inst, Shandong Acad Sci, Keyuan Rd 19, Jinan 250014, Peoples R China
[3] State Grid Henan Elect Power Res Inst, Songshan Rd 87, Zhengzhou 450052, Peoples R China
关键词
LC-double-LCC topology; Wireless power transfer; Voltage interference ratio; Harmonic analysis; THD; Sensitivity analysis;
D O I
10.1016/j.egyr.2022.02.028
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The article firstly analyzes the filtering characteristics of double-LCC circuit in wireless power transfer (WPT) system. By defining voltage interference ratio (VIR), the harmonic interference introduced by inverter output voltage square waveform is represented. The ability of suppressing harmonic voltage source interference with different frequency of each branch of compensation network is obtained by analyzing VIR. In order to further reduce the harmonic content of each branch of circuit and decrease the harmonic introduction from the input-side, the article adopts an LC-double-LCC topology circuit. That is, an LC resonant part is connected in series at the input-side of circuit. The VIR of both double-LCC and new structure are compared by building mathematical model, and it is proved that the new structure has better ability to restrain interference. The total harmonic distortion (THD) of input-side current is calculated and the relation between the values of LC part, coupling coefficient, load and THD is quantitatively expressed. The sensitivity analysis in detuning condition of two structures is conducted. When the frequency offset becomes larger, the new topology shows better effect on inhibiting the increase of capacitive and inductive degree of the input impedance angle. The efficiency of WPT system with LC-double-LCC structure is analyzed, and reactive power of input-side is expressed by the value of LC part. With the parameters selected in this article, the input reactive power decreases 55.6% and power factor increases 0.68% after adding LC part. The results of simulation and calculation show that the LC-double-LCC structure has higher efficiency and larger power factor. An experimental platform is built and the theoretical results are verified. (C) 2022 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:891 / 902
页数:12
相关论文
共 50 条
  • [41] Random phase compensation method of coherent lidar based on symmetrical double harmonic signals
    Fang, Fuping
    Hu, Heng
    Liu, Xialin
    Sheng, Juan
    Zhu, Shiyue
    Lv, Yinhuan
    Xu, Weiming
    Shu, Rong
    OPTICS COMMUNICATIONS, 2023, 529
  • [42] Harmonic Phasor Analysis Based on Improved FFT Algorithm
    Zeng, Bo
    Teng, Zhaosheng
    Cai, Yulian
    Guo, Siyu
    Qing, Baiyuan
    IEEE TRANSACTIONS ON SMART GRID, 2011, 2 (01) : 51 - 59
  • [43] Analysis Based on Improved Method for Transformer Harmonic Losses
    Pan Chao
    Kong Lingguo
    Li Zhenxin
    Zheng Qing
    Wang Zezhong
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1845 - 1851
  • [44] Lyapunov Function-Based Stabilizing Control Scheme for Wireless Power Transfer Systems with LCC Compensation Network
    Hasan, Abu Shahir Md Khalid
    Bhogaraju, Indra
    Farasat, Mehdi
    Malisoff, Michael
    2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 694 - 699
  • [45] Harmonic analysis of electrified railway based on improved HHT
    Wang, Feng
    ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS II, 2018, 1955
  • [46] Error Compensation of Photoelectric Encoder Based on Improved BP Neural Network
    Wang Xiao-gang
    Cai Tao
    Deng Fang
    Xu Li-shuang
    PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2012, : 3941 - 3946
  • [47] A Novel Optimization Method of Compensation Network Parameters for LCC Topology Wireless Power Transfer System With Anti-Offset Characteristics
    Lu, Yang
    Ge, Dongyuan
    Meng, Lian
    Sun, Chuan
    Tang, Qi
    Gao, Yilin
    Chen, Mengmeng
    Xia, Chenyang
    IEEE ACCESS, 2024, 12 : 5960 - 5972
  • [48] Estimation Method of Harmonic State Based on Improved Generative Adversarial Network
    Ma Y.
    Qi L.
    Xiao X.
    Wang H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (01): : 139 - 145
  • [49] Harmonic Current Compensation of PMSM Based on Disturbance Observer and Robustness Analysis
    Zhou, Peng
    Xu, Haiping
    Guan, Tao
    Liu, Wei
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1258 - 1263
  • [50] Time Symmetry Analysis of Nonlinear Parity Based on S-P Compensation Network Structure
    XIAO Weihao
    HUANG Xuhong
    Instrumentation, 2022, 9 (01) : 49 - 55