A Validated, Specific, Stability-Indicating RP-LC Method for Analysis of Gatifloxacin in the Presence of Degradation Products and Process-Related Impurities

被引:4
|
作者
Devi, M. Lalitha [1 ]
Chandrasekhar, K. B. [2 ]
机构
[1] US Pharmacopeia India Private Ltd, Reference Stand Lab, Hyderabad 500078, Andhra Pradesh, India
[2] JNTU Coll Engn, Dept Chem, Anantapur 515002, Andhra Pradesh, India
关键词
Column liquid chromatography; Forced degradation; Gatifloxacin;
D O I
10.1365/s10337-009-0989-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A validated, specific, stability-indicating reversed-phase liquid chromatographic method has been developed for quantitative analysis of gatifloxacin, its degradation products, and its process-related impurities in bulk samples and in pharmaceutical dosage forms. Forced degradation of gatifloxacin bulk sample was conducted in accordance with ICH guidelines. Acidic, basic, neutral, and oxidative hydrolysis, thermal stress, and photolytic degradation were used to assess the stability-indicating power of the method. Substantial degradation was observed during oxidative hydrolysis. No degradation was observed under the other stress conditions. The method was optimized using samples generated by forced degradation and sample solution spiked with impurities. Good resolution of the analyte peak from peaks corresponding to process-related impurities and degradation products was achieved on a C-18 column by use of a simple linear mobile-phase gradient prepared from mixtures of acetonitrile and an aqueous solution of sodium dihydrogen orthophosphate dihydrate and triethylamine adjusted to pH 6.5 with orthophosphoric acid. Detection was performed at 240 nm. Limits of detection and quantification were established for gatifloxacin and its process-related impurities. When the stressed test solutions were assayed by comparison with gatifloxacin working standard the mass balance was always close to 99.3%, indicating the method was stability-indicating. Validation of the method was performed in accordance with ICH requirements. The method was found to be suitable for checking the quality of bulk samples of gatifloxacin at the time of batch release and also during storage.
引用
收藏
页码:985 / 992
页数:8
相关论文
共 50 条
  • [41] Validated, Stability-Indicating LC Method for Analysis of Pipenzolate Bromide and Its Hydrolysis Products
    Ghada M. Hadad
    Chromatographia, 2008, 68 : 207 - 212
  • [42] Validated stability indicating ion-pair RP-LC method for zoledronic acid
    Rao, BM
    Srinivasu, MK
    Rani, CP
    Kumar, SS
    Kumar, PR
    Chandrasekhar, KB
    Veerender, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 781 - 790
  • [43] Development of a stability-indicating HPLC method for Lasmiditan and its process related impurities with characterization of degradation products by LC-MS/MS
    Reddy, Cherukula Srinivasa
    Babu, Chilakabattina Naga Narasimha
    Tatavarti, Bhagya Kumar
    Vijaya, Nalleboyina
    Anna, Venkateswara Rao
    JOURNAL OF CHEMICAL METROLOGY, 2023, 17 (01): : 79 - 92
  • [44] Application of ICH Guidelines for Studying the Degradation Behavior of Rocuronium Bromide Coupled with Stability-Indicating RP-LC Method
    El Houssini, Ola M.
    Abd El-Rahman, Mohamed K.
    Fahem, Diana K.
    Zaazaa, Hala E.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 217 - 223
  • [45] Validated, stability-indicating LC method for analysis of pipenzolate bromide and its hydrolysis products
    Hadad, Ghada M.
    CHROMATOGRAPHIA, 2008, 68 (3-4) : 207 - 212
  • [46] DEVELOPMENT AND VALIDATION OF A STABILITY INDICATING RP-LC METHOD FOR THE ESTIMATION OF PROCESS RELATED IMPURITIES AND DEGRADATION PRODUCTS OF DULOXETINE HYDROCHLORIDE AND PHTHALIC ACID IN DULOXETINE HYDROCHLORIDE DELAYED RELEASE CAPSULES
    Kumar, Navneet
    Sangeetha, D.
    Vaghela, Bhupendrasinh
    Reddy, P. Sunil
    Raghav, Anuj
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (07) : 867 - 881
  • [47] Development and validation of a stability-indicating RP-HPL C-CAD method for gabapentin and its related impurities in presence of degradation products
    Ragham, Pramod Kumar
    Chandrasekhar, Kothapalli B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 125 : 122 - 129
  • [48] A validated specific stability-indicating RP-HPLC method for Aripiprazole and its related substances
    Narayana, M. B. V.
    Chandrasekhar, K. B.
    Rao, B. M.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2014, 91 (03) : 439 - 447
  • [49] Synchronized stability indicating RP-LC methods for determination of metolazone with losartan potassium or spironolactone in presence of their degradation products
    Zaazaa, Hala E.
    Abdel-Ghany, Rasha
    Sayed, Mahmoud
    Abdelkawy, M.
    Atty, Shimaa A.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2020, 43 (13-14) : 474 - 481
  • [50] Validated Stability-indicating RP-HPLC Method for the Determination of Parecoxib Sodium and Degradation Impurities in Bulk Drug
    Yu, Qiuyang
    Yu, Qiuli
    Wu, Lei
    Sun, Jing
    Ma, Panqin
    Liu, Xiaojie
    Dong, Wenxiang
    Zhang, Peng
    CURRENT PHARMACEUTICAL ANALYSIS, 2017, 13 (03) : 271 - 278