Infrared temperature measurement of polymers

被引:41
|
作者
Maier, C [1 ]
机构
[1] GE CO,CORP RES & DEV,SCHENECTADY,NY 12301
来源
POLYMER ENGINEERING AND SCIENCE | 1996年 / 36卷 / 11期
关键词
D O I
10.1002/pen.10545
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Infrared (IR) thermosensors that measure the temperature of polymeric melts in processing equipment by guiding the thermal radiation along optical fibers to the optovoltaic transducer are on the market. The fundamental concepts of thermal radiation must be viewed in a volumetric sense. In sequence, a model is presented to estimate the response of such IR thermosensors. It is dictated by the volumetric absorptivity of the polymer and the transmittance of the optical fiber. For typical commercial IR thermosensors, the entire wavelength range between 1.5 and 2.2 mu m is relevant. Penetration depths can vary from magnitudes of mm to dm, since the IR probe is sensitive to the maximum temperatures in its acceptance volume. These findings were put to the test in two different experimental settings. In the first, the calculations overestimated the comparable experimental values by 10 to 20 degrees C, but were reasonable given the relatively simple experimental apparatus. In the second setup, the maximum temperature of melt coming off the screws, measured by penetrating a small thermocouple into the stream, matched the IR temperature sensor's readings. The measurement of temperature excursions in different mixing geometries is demonstrated. No kneading section with forward staggered paddles gave significant increases in temperature. In contrast, maximum temperature excursions could be measured when reverse elements were in place.
引用
收藏
页码:1502 / 1512
页数:11
相关论文
共 50 条
  • [31] MEASUREMENT OF POSITRON LIFETIMES IN SOLID POLYMERS AT ROOM TEMPERATURE
    KHAN, MNG
    CARSWELL, DJ
    BELL, J
    PHYSICS LETTERS A, 1969, A 29 (05) : 237 - &
  • [32] Study on the radiation-temperature measurement with infrared fiber at low temperature
    Yang, Wenku
    Yang, Tao
    Deng, Wenrong
    Hongwai Yu Haomibo Xuebao/Journal of Infrared and Millimeter Waves, 1996, 15 (05): : 379 - 385
  • [33] INFRARED TECHNIQUE FOR MEASUREMENT OF STRUCTURAL CHANGES DURING ORIENTATION PROCESS IN POLYMERS
    KOENIG, JL
    CORNELL, SW
    WITENHAFER, DE
    JOURNAL OF POLYMER SCIENCE PART A-2-POLYMER PHYSICS, 1967, 5 (2PA2) : 301 - +
  • [34] Temperature recovery from degenerated infrared image based on the principle for temperature measurement using infrared sensor
    Zou, Zhiyuan
    Hu, Yihua
    Gao, Bin
    Woo, W. L.
    Zhao, Xinyu
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (04)
  • [36] A study of soil surface temperature with thermal infrared measurement
    Huang, MF
    Liu, SM
    Liu, SH
    Wang, CZ
    Zhu, QJ
    IGARSS 2004: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM PROCEEDINGS, VOLS 1-7: SCIENCE FOR SOCIETY: EXPLORING AND MANAGING A CHANGING PLANET, 2004, : 1988 - 1991
  • [37] Infrared Temperature Measurement with Inherent Consideration of Emissivity.
    Tank, Volker
    Mitteilung - Deutsche Forschungs- und Versuchsanstalt fuer Luft- und Raumfahrt, 1988, (88-22):
  • [38] THE UTILIZATION OF INFRARED CAMERA FOR TEMPERATURE MEASUREMENT OF ELECTRICAL MACHINES
    Kuchynkova, Hana
    Hajek, Vitezslav
    BRNO 2010: INTERNATIONAL CONFERENCE ON LOW VOLTAGE ELECTRICAL MACHINES, 2010, : 78 - 81
  • [39] Effect of crying on infrared tympanic temperature measurement in pediatrics
    Kahyaoglu, O
    Babka, I
    Demirci, C
    Boyer, D
    CLINICAL PEDIATRICS, 1997, 36 (08) : 487 - 488
  • [40] Infrared Temperature Measurement Sensors of Overhead Power Conductors
    Castro, Pablo
    Lecuna, Ramon
    Manana, Mario
    Martin, Maria Jose
    Campo, Dolores del
    SENSORS, 2020, 20 (24) : 1 - 13