Comparison of patient doses at different CT scanners with same acquisition protocol

被引:0
|
作者
Balkay, L. [1 ]
Oszlanski, A. [1 ]
Krizsan, A. K. [1 ]
机构
[1] Univ Debrecen, Inst Nucl Med, H-4012 Debrecen, Hungary
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the last decade both the number of powerful CT scanners and the number of patient investigations increased with a consequent increase of the patient radiation dose. There are large dose variations (more than 10 fold) among individual CT centers and it remains true if they include the same model of CT scanners. The aim of this study was to compare the patient effective dose (D-e) during the CT examinations from different manufacturer models presuming the same acquisition protocol and using the imPACT patient organ and effective dose calculator program. The following manufacturers and models were selected in the program: GE (LightSpeed Ultra, LightSpeed 16, LightSpeed Pro 16, LightSpeed VCT), Philips (Brilliance 16, Brilliance 16 Power, Big Bore, Brilliance 64/40) and the Siemens (Emotion 6, Sensation 16, Sensation 16 Straton, Sensation 64, Definition AS). Head and body scans were defined for all cases altering tube voltages, while dose calculations were normalized to 100 mAs X-ray exposure. It was found that in body investigations the calculated D-e for the GE scans were higher by 20% comparing to Siemens and Philips related values. For the head examinations the differences were larger by almost 55%. We also demonstrated that a power relationship can be found between the De and the tube voltage with the exponent of 3.02+/-0.14 kV-1 and 2.68+/-0.14 kV-1 for the body and the head scans respectively. It can be concluded that the patient effective dose could be different in CT examinations using distinct CT scanners but defining the same acquisition protocol. Considering the patient dose, this also means that the scan protocols cannot be transferred between different models without specific investigation.
引用
收藏
页码:3644 / 3645
页数:2
相关论文
共 50 条
  • [1] Comparison of patient doses in 256-slice CT and 16-slice CT scanners
    Mori, S
    Endo, M
    Nishizawa, K
    Murase, K
    Fujiwara, H
    Tanada, S
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (937): : 56 - 61
  • [2] Validating Dose Split: A Method to Image the Same Patient at Multiple Doses with a Single CT Acquisition
    Solomon, J.
    Zhang, Y.
    Marin, D.
    Samei, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3642 - 3642
  • [3] COMPARISON OF CT SCANNERS
    GOODENOUGH, DJ
    WEAVER, K
    DAVIS, DO
    NEURORADIOLOGY, 1976, 12 (01) : 47 - 47
  • [4] A QUALITY ASSURANCE PROTOCOL FOR CT SCANNERS
    DROEGE, RT
    RADIOLOGY, 1983, 146 (01) : 244 - 246
  • [5] Comparison of between PET-CT Scanners with Different Physical Characteristics
    Iwase, Mikio
    Tomita, Yoya
    Hayashi, Emi
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [6] Estimation of conversion coefficients for absorbed and effective doses for pediatric CT examinations in two different PET/CT scanners
    Perini, Ana P.
    Santos, William S.
    Neves, Lucio P.
    Belinato, Walmir
    Caldas, Linda V. E.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 9 - 16
  • [7] Comparison of patient effective doses from multiple CT examinations based on different calculation methods
    Avramova-Cholakova, Simona
    Dyakov, Iliya
    Yordanov, Hristomir
    O'Sullivan, James
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 99 : 73 - 84
  • [8] Image Quality and Patient-Specific Organ Doses in Stone Protocol CT: A Comparison of Traditional CT to Low Dose CT with Iterative Reconstruction
    Pai, Raghav
    Modh, Rishi
    Lamoureux, Rebecca H.
    Deitte, Lori
    Wymer, David C.
    Mench, Anna
    Lipnharski, Izabella
    Henriksen, Carl
    Arreola, Manuel
    Canales, Benjamin K.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [9] Comparison of doses received from non-contrast enhanced brain CT examinations between two CT scanners
    Zatkuliakova, Veronika
    Stevik, Martin
    Vorcak, Martin
    Sykora, Jan
    Trabalkova, Zuzana
    Broocks, Gabriel
    Meyer, Lukas
    Fiehler, Jens
    Zelenak, Kamil
    HELIYON, 2024, 10 (17)
  • [10] Dosimetric and image quality comparison of different 64-slice CT scanners
    Colli, V.
    Strocchi, S.
    Vite, C.
    Cacciatori, M.
    Rizzi, E.
    Marzoli, L.
    Conte, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 197 - 200