Comparative in vitro performance of valved holding chambers with a budesonide/formoterol pressurized metered-dose inhaler

被引:7
|
作者
Chambers, Frank E. [1 ]
Brown, Steven [1 ]
Ludzik, Andrew J. [1 ]
机构
[1] AstraZeneca R&D Charnwood, Pharmaceut & Analyt R&D, Loughborough LE11 5RH, Leics, England
关键词
Asthma; budesonide/formoterol; corticosteroid; delivered dose; drug delivery; fine particle dose; long-acting beta(2)-adrenergic agonist; pressurized metered-dose inhaler; tidal breathing pattern; valved holding chamber; ELECTROSTATIC CHARGE; MULTIPLE ACTUATIONS; AEROSOL DELIVERY; PLASTIC SPACERS; DEVICES; BUDESONIDE; FORMOTEROL; EFFICACY; FACEMASK; THERAPY;
D O I
10.2500/aap.2009.30.3252
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
A combination of budesonide and formoterol in a single pressurized metered-dose inhaler (pMDI) is available in the United States and elsewhere. This study was designed to evaluate the delivered dose and fine particle dose (FPD; mass of particles <4.7-micrometer diameter) using the pMDI with two valved holding chambers (VHCs), using sampling methods reflecting different patient techniques. FPD was measured using an Andersen Cascade Impactor and delivered dose was measured using a disposable filter. Two VHCs, AeroChamber Plus and AeroChamber MAX (Trudell Medical International, London, Ontario, Canada), were evaluated using three sampling methods: (1) immediate collection; (2) collection after tip to a 5-second delay, (3) using simulated adult, child, and infant tidal breathing patterns (delivered dose). Decreases in delivered dose were observed using a VHC compared with the pMDI alone. FPD with both VHCs was similar to that with the pMDI alone with minimal delay between actuation and collection. With delays, the antistatic AeroChamber MAX was more resistant than AeroChamber Plus to dose losses. Delivered doses from adult and child profiles were comparable with those after a I-second delay. The infant profile produced lower delivered doses, probably because more breath cycles are required to empty the VHC. Budesonide/formoterol pMDI can be used effectively with AeroChamber Plus and the antistatic AeroChamber MAX. With minimal delay between actuation and collection, FPD with both VHCs was similar to that with the pMDI alone, giving physicians a choice of administration regimen and taking into account the needs and skills of the patient. (Allergy Asthma Proc 30:424-432, 2009; doi: 10.2500/aap.2009.30.3252)
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
  • [1] Budesonide/Formoterol Pressurized Metered-Dose Inhaler
    Katherine A. Lyseng-Williamson
    Dene Simpson
    Drugs, 2008, 68 : 1855 - 1864
  • [2] Budesonide/formoterol pressurized metered-dose inhaler
    Lyseng-Willianison, Katherine A.
    Simpson, Dene
    DRUGS, 2008, 68 (13) : 1855 - 1864
  • [3] Comparative In Vitro Performance of Three Small-Volume Valved Holding Chambers with Beclomethasone/Formoterol Pressurized Metered Dose Inhaler
    Goncalves, Talita Mota
    Alhanout, Kamel
    Nicolay, Alain
    Dubus, Jean-Christophe
    de Santana, Davi Pereira
    Andrieu, Veronique
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (04) : 223 - 227
  • [4] In Vitro Drug Delivery Performance of a New Budesonide/Formoterol Pressurized Metered-Dose Inhaler
    Chambers, Frank
    Ludzik, Andrew
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2009, 22 (02) : 113 - 120
  • [5] Budesonide/formoterol pressurized metered-dose inhaler for patients with persistent asthma
    Korenblat, Phillip E.
    Rosenwasser, Lanny J.
    ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (03) : 190 - 202
  • [6] In vitro performance of two common valved holding chambers with a chlorofluorocarbon-free beclomethasone metered-dose inhaler
    Asmus, MJ
    Coowanitwong, I
    Kwon, SH
    Khorsand, N
    Hochhaus, G
    PHARMACOTHERAPY, 2003, 23 (12): : 1538 - 1544
  • [7] In Vitro Performance of Fluticasone/Salmeterol Pressurized Metered Dose Inhaler in Combination with Three Different Valved Holding Chambers
    Goncalves, Talita M.
    Rizzo, Jose A.
    Dubus, Jean-Christophe
    Nicolay, Alain
    De Santana, Davi P.
    De Souza, Pedro H. N.
    Figueiroa, Jose N.
    Andrieu, Veronique
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (06): : 877 - 882
  • [9] The functionality of a budesonide/formoterol pressurized metered-dose inhaler with an integrated actuation counter
    Shah, Shailen
    White, Martha
    Uryniak, Tom
    O'Brien, Christopher D.
    ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (01) : 40 - 48
  • [10] Budesonide/Formoterol Pressurized Metered-Dose Inhaler In Chronic Obstructive Pulmonary Disease
    Lyseng-Williamson, Katherine A.
    DRUGS, 2009, 69 (11) : 1459 - 1470