Usefulness of rapid low-dose/high-dose 1-day 99mTc-sestamibi ECG-gated myocardial perfusion single-photon emission computed tomography

被引:17
|
作者
Matsumoto, Naoya
Sato, Yuichi
Suzuki, Yasuyuki
Yoda, Shunichi
Kunimasa, Taeko
Kato, Masahiko
Tadehara, Futoshi
Lewin, Howard C.
Hyun, Mark C.
Saito, Satoshi
机构
[1] Nihon Univ, Sch Med, Dept Cardiol, Tokyo 1018309, Japan
[2] Kure Kyosai Hosp, Kure, Japan
[3] Cardiac Imaging Associates, Los Angeles, CA USA
关键词
coronary artery disease; Tc-99m-sestamibi SPECT; single-photon emission computed tomography;
D O I
10.1253/circj.70.1585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The clinical usefulness of a rapid rest low-close/stress high-dose (dose ratio=1:5) Tc-99(m)-sestamibimyocardial perfusion single-photon emission computed tomography (SPECT) protocol for the detection of coronary artery disease was evaluated. Methods and Results In 89 patients, rest images were obtained immediately after the injection of Tc-99m-sestamibi (256.1 +/- 28.4 MBq) followed by drinking water (400ml). Exercise or vasodilator stress test was performed immediately after the completion of rest imaging with the injection of Tc-99m-sestamibi (1312.3 +/- 167.6 MBq). Prior to the post-stress imaging, patients were asked again to drink water (400 ml) in order to eliminate subdiaphragmatic tracer activity. The myocardial count ratio (stress/rest) of Tc-99m-sestamibi was calculated. Image quality was scored using a 4-point scale system (4=excellent, 3=good, 2=poor, 1=unacceptable). Coronary angiography was performed in 56 patients within I month of the SPECT scan. All patients successfully performed the protocol and total examination time was 108 +/- 7 min. The myocardial count ratio of Tc-99m-sestamibi was always greater than 6. The image quality was satisfactory both at rest (3.4 +/- 0.9) and after stress (3.9 +/- 0.2). The sensitivity and specificity to detect coronary artery stenosis > 50% was 84% and 97%, respectively. Conclusions This rapid one-day Tc-99m-sestamibi protocol provides adequate image quality and diagnostic accuracy for detecting coronary artery disease.
引用
收藏
页码:1585 / 1589
页数:5
相关论文
共 50 条
  • [41] Different methods for the detection of small changes in uptake between single-photon emission computed tomography (SPECT) examinations:: 99mTc-sestamibi in chemotherapy for breast tumours
    Jacobsson, H
    Wilczek, B
    Bergh, J
    von Schoultz, E
    Eriksson, E
    Larsson, SA
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (04) : 347 - 352
  • [42] Does 99mTc-sestamibi single-photon emission computed tomography stress testing detect coronary artery disease in patients being evaluated for chest pain?
    Michel, J
    Royal, S
    Wagner, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (2A): : 80E - 80E
  • [43] Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography
    Ficaro, EP
    Fessler, JA
    Shreve, PD
    Kritzman, JN
    Rose, PA
    Corbett, JR
    CIRCULATION, 1996, 93 (03) : 463 - 473
  • [44] Detection of myocardial contractile reserve by low-dose Dobutamine quantitative gated single-photon emission computed tomography in patients with Kawasaki disease and severe coronary artery lesions
    Karasawa, K
    Miyashita, M
    Taniguchi, K
    Kanamaru, H
    Ayusawa, M
    Noto, N
    Sumitomo, N
    Okada, T
    Harada, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (07): : 865 - 868
  • [45] Prevalence of Perfusion Defects Detected by Stress 99mTechnetium Sestamibi Myocardial Perfusion Single-photon Emission Computed Tomography in Asymptomatic Patients with Breast Cancer
    Melichar, Bohuslav
    Dolezal, Jiri
    Sramek, Vlastislav
    Kalabova, Hana
    Krcmova, Lenka Kujovska
    Hyspler, Radomir
    Studentova, Hana
    Vosmik, Milan
    Pecka, Miroslav
    Svobodnik, Adam
    Pecen, Ladislav
    Dolezel, Martin
    Solichova, Dagmar
    ANTICANCER RESEARCH, 2014, 34 (07) : 3689 - 3694
  • [46] Radiation dose reduction utilizing new technology and low dose protocols in myocardial perfusion single photon emission computed tomography (MPS)
    Prasad, Kalpna
    Bonavia, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [47] Additive value of low-dose dobutamine to technetium-99m sestamibi-gated single-photon emission computed tomography for prediction of wall motion improvement in patients undergoing coronary artery bypass graft
    Zafrir, N
    Arditi, A
    Ben-Gal, T
    Solodky, A
    Hassid, Y
    Sulkes, J
    Battler, A
    CLINICAL CARDIOLOGY, 2003, 26 (11) : 530 - 535
  • [48] Detection of occult left ventricular dysfunction in patients without prior clinical history of myocardial infarction by technetium-99m sestamibi myocardial perfusion gated single-photon emission computed tomography
    Yao, SS
    Nichols, K
    DePuey, EG
    Rozanski, A
    CLINICAL CARDIOLOGY, 2002, 25 (09) : 429 - 435
  • [49] Prediction of recovery of left ventricular dysfunction after acute myocardial infarction:: Comparison between 99mTc-sestamibi cardiac tomography and low-dose dobutamine echocardiography
    Spinelli, L
    Petretta, M
    Cuocolo, A
    Nicolai, E
    Acampa, W
    Vicario, L
    Bonaduce, D
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (10) : 1683 - 1692
  • [50] Myocardial viability in chronic ischemic heart disease: comparison of delayed-enhancement magnetic resonance imaging with 99mTc-sestamibi and 18F-fluorodeoxyglucose single-photon emission computed tomography
    Liu, Qiong
    Zhao, Shihua
    Yan, Chaowu
    Lu, Minjie
    Jiang, Shiliang
    Zhang, Yan
    Li, Shiguo
    Liu, Yuqing
    Yang, Minfu
    He, Zuoxiang
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (08) : 610 - 616