Simulation of longitudinal stent deformation in a patient-specific coronary artery

被引:42
|
作者
Ragkousis, Georgios E. [1 ]
Curzen, Nick [2 ,3 ]
Bressloff, Neil W. [1 ]
机构
[1] Univ Southampton, Computat Engn & Design Grp, Fac Engn & Environm, Southampton SO17 1BJ, Hants, England
[2] Southampton Univ Hosp NHS Trust, Southampton, Hants, England
[3] Univ Southampton, Fac Med, Southampton SO17 1BJ, Hants, England
关键词
Longitudinal stent deformation; Stents; Stent malapposition; Finite element analysis; Patient specific model; DESIGN; MALAPPOSITION; IMPLANTATION; COMPRESSION; APPOSITION;
D O I
10.1016/j.medengphy.2014.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In percutaneous coronary intervention (PCI), stent malapposition is a common complication often leading to stent thrombosis (ST). More recently, it has also been associated with longitudinal stent deformation (LSD) normally occurring through contact of a post balloon catheter tip and the protruding malapposed stent struts. The aim of this study was to assess the longitudinal integrity of first and second generation drug eluting stents in a patient specific coronary artery segment and to compare the range of variation of applied loads with those reported elsewhere. We successfully validated computational models of three drug-eluting stent designs when assessed for longitudinal deformation. We then reconstructed a patient specific stenosed right coronary artery segment by fusing angiographic and intravascular ultrasound (IVUS) images from a real case. Within this model the mechanical behaviour of the same stents along with a modified device was compared. Specifically, after the deployment of each device, a compressive point load of 0.3 N was applied on the most malapposed strut proximally to the models. Results indicate that predicted stent longitudinal strength (i) is significantly different between the stent platforms in a manner consistent with physical testing in a laboratory environment, (ii) shows a smaller range of variation for simulations of in vivo performance relative to models of in vitro experiments, and (iii) the modified stent design demonstrated considerably higher longitudinal integrity. Interestingly, stent longitudinal stability may differ drastically after a localised in vivo force compared to a distributed in vitro force. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:467 / 476
页数:10
相关论文
共 50 条
  • [21] Modeling of Damage Evolution in a Patient-Specific Stenosed Artery upon Stent Deployment
    Rouhani, Fatemeh
    Fereidoonnezhad, Behrooz
    Zakerzadeh, Mohammad Reza
    Baghani, Mostafa
    [J]. INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2020, 12 (09)
  • [22] It's a Trap: A Case of Strangulated Coronary Guidewire and Longitudinal Stent Deformation in the Right Coronary Artery
    Rehman, Adeel Ur
    Malik, Jahanzeb
    Iftikhar, Imran
    Javed, Asim
    Jalal, Anjum
    Satti, Khawar
    [J]. AMERICAN JOURNAL OF CASE REPORTS, 2021, 22
  • [23] Multi-objective optimisation of stent dilation strategy in a patient-specific coronary artery via computational and surrogate modelling
    Ragkousis, Georgios E.
    Curzen, Nick
    Bressloff, Neil W.
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (02) : 205 - 215
  • [24] SIMULATION OF STENT DEPLOYMENT IN PATIENT-SPECIFIC CEREBRAL ANEURYSM MODELS FOR THEIR HEMODYNAMICS ANALYSIS
    Mut, Fernando
    Appanaboyina, Sunil
    Cebral, Juan R.
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 267 - 268
  • [25] Patient-specific Surgical Simulation
    Luc Soler
    Jacques Marescaux
    [J]. World Journal of Surgery, 2008, 32 : 208 - 212
  • [26] Patient-specific surgical simulation
    Soler, Luc
    Marescaux, Jacques
    [J]. WORLD JOURNAL OF SURGERY, 2008, 32 (02) : 208 - 212
  • [27] Applicability of Patient-Specific Simulation
    Wytyczak-Partyka, Andrzej
    Nikodem, Jan
    Klempous, Ryszard
    [J]. COMPUTER AIDED SYSTEMS THEORY - EUROCAST 2015, 2015, 9520 : 457 - 462
  • [28] PATIENT-SPECIFIC MODELING AND HEMODYNAMIC SIMULATION IN HEALTHY AND DISEASED CORONARY ARTERIES
    Itu, Lucian
    Sharma, Puneet
    Zheng, Xudong
    Mihalef, Viorel
    Kamen, Ali
    Suciu, Constantin
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 583 - 584
  • [29] The Impact of Boundary Conditions in Patient-Specific Coronary Blood Flow Simulation
    Uus, Alena
    Liatsis, Panos
    Rajani, Ronak
    Mandic, Lidija
    [J]. 21ST INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2014), 2014, : 35 - 38
  • [30] Patient-Specific Simulation of Coronary Artery Pressure Measurements: An In Vivo Three-Dimensional Validation Study in Humans
    Siogkas, Panagiotis K.
    Papafaklis, Michail I.
    Sakellarios, Antonis I.
    Stefanou, Kostas A.
    Bourantas, Christos V.
    Athanasiou, Lambros S.
    Exarchos, Themis P.
    Naka, Katerina K.
    Michalis, Lampros K.
    Parodi, Oberdan
    Fotiadis, Dimitrios I.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015