Simulation of longitudinal stent deformation in a patient-specific coronary artery

被引:42
|
作者
Ragkousis, Georgios E. [1 ]
Curzen, Nick [2 ,3 ]
Bressloff, Neil W. [1 ]
机构
[1] Univ Southampton, Computat Engn & Design Grp, Fac Engn & Environm, Southampton SO17 1BJ, Hants, England
[2] Southampton Univ Hosp NHS Trust, Southampton, Hants, England
[3] Univ Southampton, Fac Med, Southampton SO17 1BJ, Hants, England
关键词
Longitudinal stent deformation; Stents; Stent malapposition; Finite element analysis; Patient specific model; DESIGN; MALAPPOSITION; IMPLANTATION; COMPRESSION; APPOSITION;
D O I
10.1016/j.medengphy.2014.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In percutaneous coronary intervention (PCI), stent malapposition is a common complication often leading to stent thrombosis (ST). More recently, it has also been associated with longitudinal stent deformation (LSD) normally occurring through contact of a post balloon catheter tip and the protruding malapposed stent struts. The aim of this study was to assess the longitudinal integrity of first and second generation drug eluting stents in a patient specific coronary artery segment and to compare the range of variation of applied loads with those reported elsewhere. We successfully validated computational models of three drug-eluting stent designs when assessed for longitudinal deformation. We then reconstructed a patient specific stenosed right coronary artery segment by fusing angiographic and intravascular ultrasound (IVUS) images from a real case. Within this model the mechanical behaviour of the same stents along with a modified device was compared. Specifically, after the deployment of each device, a compressive point load of 0.3 N was applied on the most malapposed strut proximally to the models. Results indicate that predicted stent longitudinal strength (i) is significantly different between the stent platforms in a manner consistent with physical testing in a laboratory environment, (ii) shows a smaller range of variation for simulations of in vivo performance relative to models of in vitro experiments, and (iii) the modified stent design demonstrated considerably higher longitudinal integrity. Interestingly, stent longitudinal stability may differ drastically after a localised in vivo force compared to a distributed in vitro force. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:467 / 476
页数:10
相关论文
共 50 条
  • [1] Finite Element Modelling of Stent Deployment in a Patient-specific Coronary Artery
    He, Ran
    Zhao, Liguo
    Silberschmidt, Vadim V.
    Liu, Yang
    Vogt, Felix
    [J]. INTERNATIONAL CONFERENCE ON STENTS: MATERIALS, MECHANICS AND MANUFACTURING (ICS3M 2019), 2019, 15 : 28 - 32
  • [2] Patient-specific computational simulation of coronary artery bifurcation stenting
    Zhao, Shijia
    Wu, Wei
    Samant, Saurabhi
    Khan, Behram
    Kassab, Ghassan S.
    Watanabe, Yusuke
    Murasato, Yoshinobu
    Sharzehee, Mohammadali
    Makadia, Janaki
    Zolty, Daniel
    Panagopoulos, Anastasios
    Burzotta, Francesco
    Migliavacca, Francesco
    Johnson, Thomas W.
    Lefevre, Thierry
    Lassen, Jens Flensted
    Brilakis, Emmanouil S.
    Bhatt, Deepak L.
    Dangas, George
    Chiastra, Claudio
    Stankovic, Goran
    Louvard, Yves
    Chatzizisis, Yiannis S.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [3] Patient-specific computational simulation of coronary artery bifurcation stenting
    Shijia Zhao
    Wei Wu
    Saurabhi Samant
    Behram Khan
    Ghassan S. Kassab
    Yusuke Watanabe
    Yoshinobu Murasato
    Mohammadali Sharzehee
    Janaki Makadia
    Daniel Zolty
    Anastasios Panagopoulos
    Francesco Burzotta
    Francesco Migliavacca
    Thomas W. Johnson
    Thierry Lefevre
    Jens Flensted Lassen
    Emmanouil S. Brilakis
    Deepak L. Bhatt
    George Dangas
    Claudio Chiastra
    Goran Stankovic
    Yves Louvard
    Yiannis S. Chatzizisis
    [J]. Scientific Reports, 11
  • [4] Patient-specific computational simulation of coronary artery bypass grafting
    Wu, Wei
    Panagopoulos, Anastasios Nikolaos
    Vasa, Charu Hasini M.
    Sharzehee, Mohammadali
    Zhao, Shijia
    Samant, Saurabhi M.
    Oguz, Usama M. S.
    Khan, Behram
    Naser, Abdallah S.
    Harmouch, Khaled M.
    Kassab, Ghassan S.
    Siddique, Aleem
    Chatzizisis, Yiannis S.
    [J]. PLOS ONE, 2023, 18 (03):
  • [5] Patient-specific, multiscale, myocardial blood flow simulation for coronary artery disease
    Papamanolis, L.
    Kim, H. J.
    Jaquet, C.
    Sinclair, M.
    Schaap, M.
    Danad, I.
    van Diemen, P.
    Knaapen, P.
    Najman, L.
    Talbot, H.
    Taylor, C. A.
    Vignon-Clementel, I. E.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S218 - S220
  • [6] Patient-specific simulation in carotid artery stenting
    Willaert, Willem
    Aggarwal, Rajesh
    Bicknell, Colin
    Hamady, Mo
    Darzi, Ara
    Vermassen, Frank
    Cheshire, Nicholas
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) : 1700 - 1705
  • [7] Patient-specific Coronary Artery Blood Flow Simulation using Myocardial Volume Partitioning
    Kim, Kyung Hwan
    Kang, Dongwoo
    Kang, Nahyup
    Kim, Ji-Yeon
    Lee, Hyong-Euk
    Kim, James D. K.
    [J]. MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [8] Myocardial Perfusion Simulation for Coronary Artery Disease: A Coupled Patient-Specific Multiscale Model
    Lazaros Papamanolis
    Hyun Jin Kim
    Clara Jaquet
    Matthew Sinclair
    Michiel Schaap
    Ibrahim Danad
    Pepijn van Diemen
    Paul Knaapen
    Laurent Najman
    Hugues Talbot
    Charles A. Taylor
    Irene Vignon-Clementel
    [J]. Annals of Biomedical Engineering, 2021, 49 : 1432 - 1447
  • [9] Hemodynamic analysis of patient-specific coronary artery tree
    Zhang, Jun-Mei
    Luo, Tong
    Tan, Swee Yaw
    Lomarda, Aileen Mae
    Wong, Aaron Sung Lung
    Keng, Felix Yung Jih
    Allen, John Carson
    Huo, Yunlong
    Su, Boyang
    Zhao, Xiaodan
    Wan, Min
    Kassab, Ghassan S.
    Tan, Ru San
    Zhong, Liang
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (04) : e02708
  • [10] Myocardial Perfusion Simulation for Coronary Artery Disease: A Coupled Patient-Specific Multiscale Model
    Papamanolis, Lazaros
    Kim, Hyun Jin
    Jaquet, Clara
    Sinclair, Matthew
    Schaap, Michiel
    Danad, Ibrahim
    van Diemen, Pepijn
    Knaapen, Paul
    Najman, Laurent
    Talbot, Hugues
    Taylor, Charles A.
    Vignon-Clementel, Irene
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (05) : 1432 - 1447