The development of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of morphine, morphine-3-β-glucuronide, morphine-6-β-glucuronide, hydromorphone, and normorphine in serum

被引:16
|
作者
Sartori, David [1 ]
Lewis, Tamorah [2 ]
Breaud, Autumn [1 ]
Clarke, William [1 ]
机构
[1] Johns Hopkins Univ, Dept Pathol, Sch Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Pediat, Sch Med, Baltimore, MD 21287 USA
关键词
HPLC-MS/MS; Neonatal abstinence syndrome; Morphine; Glucuronide; Method validation; NEONATAL ABSTINENCE SYNDROME; CHRONIC PAIN PATIENTS; METABOLITES; OPIOIDS;
D O I
10.1016/j.clinbiochem.2015.05.023
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Development and validation of a selective, robust high-performance liquid chromatographytandem mass spectrometric (HPLC/MS-MS) method for the quantification of morphine, morphine-3-beta-glucuronide, morphine-6-beta-glucuronide, hydromorphone, and normorphine in human serum. Design and methods: Drug-free human serum samples spiked with morphine, morphine-3-beta-glucuronide, morphine-6-beta-glucuronide, hydromorphone, and normorphine were prepared by protein precipitation using methanol containing the internal standards. Samples were injected onto a Thermo Scientific AccuCore PFP column for chromatographic separation. Detection was achieved using a Thermo Scientific TSQ Vantage mass spectrometer. Assay validation followed the new Clinical and Laboratory Standards Institute (CLSI) C62-A guidelines. Results: The analytical measuring range for all analytes was determined to be 5 to 1000 ng/mL. Intra-and inter-assay precision for three quality control levels were <= 7.0% and <= 13.5%, respectively. Carryover, stability, linearity, matrix effects, extraction and processing efficiency and method comparison characteristics were acceptable relative to the CLSI C62 guidelines. Conclusion: The validation of this HPLC-MS/MS method demonstrated a robust and rapid assay for the quantification of morphine, morphine-3-beta-glucuronide, morphine-6-beta-glucuronide, hydromorphone, and normorphine. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1283 / 1290
页数:8
相关论文
共 50 条
  • [31] Development and validation of a UPLC-MS/MS method with a broad linear dynamic range for the quantification of morphine, morphine-3-glucuronide and morphine-6-glucuronide in mouse plasma and tissue homogenates
    Heydari, P.
    Martins, M. L. F.
    Rosing, H.
    Hillebrand, M. J. X.
    Gebretensae, A.
    Schinkel, A. H.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1166
  • [32] Development and validation of a UPLC-MS/MS method with a broad linear dynamic range for the quantification of morphine, morphine-3-glucuronide and morphine-6-glucuronide in mouse plasma and tissue homogenates
    Heydari, P.
    Martins, M. L. F.
    Rosing, H.
    Hillebrand, M. J. X.
    Gebretensae, A.
    Schinkel, A. H.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1166
  • [33] DIRECT DETERMINATION OF CODEINE, NORCODEINE, MORPHINE AND NORMORPHINE WITH THEIR CORRESPONDING O-GLUCURONIDE CONJUGATES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    VERWEYVANWISSEN, CPWGM
    KOOPMANKIMENAI, PM
    VREE, TB
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (02): : 309 - 320
  • [34] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE AND ITS 3-GLUCURONIDE AND 6-GLUCURONIDE METABOLITES - IMPROVEMENTS TO THE METHOD AND APPLICATION TO STABILITY STUDIES
    MILNE, RW
    NATION, RL
    REYNOLDS, GD
    SOMOGYI, AA
    VANCRUGTEN, JT
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 565 (1-2): : 457 - 464
  • [35] A liquid chromatography-tandem mass spectrometric method for quantification of curcumin-O-glucuronide and curcumin in human plasma
    Chen, Wei
    Fan-Havard, Patty
    Yee, Lisa D.
    Cao, Yu
    Stoner, Gary D.
    Chan, Kenneth K.
    Liu, Zhongfa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 900 : 89 - 93
  • [36] SIMULTANEOUS QUANTIFICATION OF ZIDOVUDINE AND ITS GLUCURONIDE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GOOD, SS
    REYNOLDS, DJ
    DEMIRANDA, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (01): : 123 - 133
  • [37] Development and validation of a high-performance liquid chromatography-tandem mass spectrometric method for quantification of daunorubicin in rat plasma
    Yang, Yuhui
    TALANTA, 2007, 71 (02) : 596 - 604
  • [38] SIMPLE METHOD FOR THE DETERMINATION OF MORPHINE AND ITS ACTIVE GLUCURONIDE METABOLITE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    MASON, JL
    ASHMORE, SP
    AITKENHEAD, AR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01): : 191 - 197
  • [39] High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Quantification of Carbamazepine, Oxcarbazepine, and Their Main Metabolites in Human Serum
    Lionetto, Luana
    Casolla, Barbara
    Cavallari, Michele
    Tisei, Paolo
    Buttinelli, Carla
    Simmaco, Maurizio
    THERAPEUTIC DRUG MONITORING, 2012, 34 (01) : 53 - 58
  • [40] A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry
    Clavijo, Claudia F.
    Hoffman, Keith L.
    Thomas, James J.
    Carvalho, Brendan
    Chu, Larry F.
    Drover, David R.
    Hammer, Gregory B.
    Christians, Uwe
    Galinkin, Jeffrey L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (03) : 715 - 728