External micro-PIXE measurements:: Preliminary results on volcanic rocks from Nyiragongo Volcano

被引:5
|
作者
Santo, Alba P. [1 ]
Fedi, Mariaelena
Giuntini, Lorenzo
Mando, Pier Andrea
Massi, Mirko
Taccetti, Francesco
机构
[1] Univ Florence, Dipartimento Sci Terra, I-50121 Florence, Italy
[2] Univ Florence, Dipartimento Fis, I-50121 Florence, Italy
[3] Ist Nazl Fis Nucl, Sez Firenze, I-50125 Florence, Italy
关键词
external micro-PIXE; trace elements; volcanic rocks;
D O I
10.1007/s00604-006-0553-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The external microbeam facility at the 3 MV Tandetron accelerator of the LABEC Laboratory of INFN in Florence has been used to determine, by PIXE, major, minor and trace element abundances of minerals and groundmass in the lavas from the active Nyiragongo Volcano (Democratic Republic of Congo), which is well known for its lava lake intra-crateric activity [e.g. 1, 2]. During the last eruption of this volcano (January, 2002), two main flows entered the Goma town producing major devastation, forcing the rapid exodus of about 300,000 people and causing the death of 150 persons [3]. After this eruption, the interest of the scientific community on this volcanic area suddenly increased. In this respect, determination of major and trace element abundances in mineral phases and groundmass of lavas may allow to constrain the evolution of magma within the volcanic system from a quantitative view point, thus helping to better understand the way this volcano works. PIXE measurements have been performed in a two-detector setup that makes it possible to simultaneously detect and quantify all elements from Na to the heaviest ones; possible compositional zoning effects in the crystals can also be reliably measured thanks to the good space resolution of the microbeam facility (better than 10 mu m) and to the possibility of performing one- and bi-dimensional scans over the areas of interest. Concentration maps of all elements can be obtained, both on-line and a posteriori: the data are collected with a list-mode acquisition system, which allows the distribution of any detected element to be reconstructed after completing the scan.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 50 条
  • [21] Investigation of impact materials from the Barringer Meteor Crater by micro-XANES and micro-PIXE techniques
    Szikszai, Z.
    Uzonyi, I.
    Kiss, A. Z.
    Sziki, G. A.
    Vantelon, D.
    Rozsa, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (12-13): : 2229 - 2232
  • [22] Evolution and genesis of volcanic rocks from Mutnovsky Volcano, Kamchatka
    Simon, A.
    Yogodzinski, G. M.
    Robertson, K.
    Smith, E.
    Selyangin, O.
    Kiryukhin, A.
    Mulcahy, S. R.
    Walker, J. D.
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2014, 286 : 116 - 137
  • [23] Micro-PIXE analysis of doped SiO2 fibres intended as TL dosimeters for radiation measurements
    Sani, S. F. Abdul
    Grime, G. W.
    Palitsin, V.
    Mahdiraji, G. A.
    Rashid, H. A. Abdul
    Maah, M. J.
    Bradley, D. A.
    X-RAY SPECTROMETRY, 2015, 44 (02) : 33 - 40
  • [24] MICRO-PIXE ANALYSES OF CARBONATE MINERALS FROM THE LOWER ZECHSTEIN KUPFERSCHIEFER FORMATION (POLAND)
    PRZYBYLOWICZ, W
    PIESTRZYNSKI, A
    TRAXEL, K
    BAJT, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 509 - 513
  • [25] MEASUREMENTS OF TRACE-ELEMENT CONCENTRATION PROFILES ACROSS THE DIAMETER OF HUMAN-HAIR WITH MICRO-PIXE
    BOS, AJJ
    VANDERSTAP, CCAH
    LENGLET, WJM
    VIS, RD
    VALKOVIC, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1249 - 1251
  • [26] The use of external micro-PIXE to investigate the factors determining the Sr:Ca ratio in the shells of fossil aragonitic molluscs
    Purton-Hildebrand, LMA
    Grime, GW
    Shields, GA
    Brasier, MD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 506 - 510
  • [27] External scanning micro-PIXE for the characterization of a polycapillary lens: Measurement of the collected X-ray intensity distribution
    Grassi, N.
    Guazzoni, C.
    Alberti, R.
    Klatka, T.
    Bjeoumikhov, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (11-12): : 1945 - 1948
  • [28] Micro-PIXE analysis of monazite from the Dora Maira Massif, Western Italian Alps
    Vaggelli, Gloria
    Borghi, Alessandro
    Cossio, Roberto
    Fedi, Mariaelena
    Giuntini, Lorenzo
    Lombardo, Bruno
    Marino, Aldo
    Massi, Mirko
    Olmi, Filippo
    Petrelli, Maurizio
    MICROCHIMICA ACTA, 2006, 155 (1-2) : 305 - 311
  • [29] Micro-PIXE Analysis of Monazite from the Dora Maira Massif, Western Italian Alps
    Gloria Vaggelli
    Alessandro Borghi
    Roberto Cossio
    Mariaelena Fedi
    Lorenzo Giuntini
    Bruno Lombardo
    Aldo Marino
    Mirko Massi
    Filippo Olmi
    Maurizio Petrelli
    Microchimica Acta, 2006, 155 : 305 - 311
  • [30] Cathodoluminescence spectroscopy and micro-PIXE: combined high resolution Mn-analyses in dolomites - First results
    Gillhaus, A
    Habermann, D
    Meijer, J
    Richter, DK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 : 842 - 845