Characteristics of drug-eluting stent platforms potentially influencing bifurcated lesion provisional stenting procedure

被引:18
|
作者
Burzotta, Francesco [1 ]
Mortier, Peter [2 ,3 ]
Trani, Carlo [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Inst Cardiol, I-00141 Rome, Italy
[2] Ghent Univ Hosp, Inst Biomed Technol, bioMMeda, Ghent, Belgium
[3] FEops Bvba, Ghent, Belgium
关键词
bifurcated lesions; drug-eluting stent; provisional T-stenting; OPTICAL COHERENCE TOMOGRAPHY; NORDIC-BALTIC BIFURCATION; FRACTIONAL FLOW RESERVE; CORONARY STENT; 3-DIMENSIONAL ANALYSIS; BALLOON INFLATION; LEFT MAIN; COMPRESSION; DILATATION; EXPANSION;
D O I
10.4244/EIJV10I1A19
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We aimed to review the technical characteristics of DES platforms which have been documented to influence bifurcation stenting procedures conducted according to the provisional approach. Methods and results: DES platforms have remarkable technical differences (side cell diameter, shape, deformability, etc.). We reviewed the literature data and performed original virtual bench tests to highlight the characteristics of DES platforms which influence the following phases of bifurcation stenting conducted according to the provisional approach: stent implantation in the main vessel across side-branch take-off ("crossover" stenting), proximal optimisation technique, rewiring and kissing balloon inflation. Available data show that the response of different DES platforms to the various procedural steps of provisional stenting is different. Conclusions: When treating bifurcated lesions according to the provisional stenting approach, the search for an ideal matching between individual bifurcated anatomy and DES selection should take into account an articulated series of technical parameters.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 50 条
  • [31] Provisional main branch stenting with drug-eluting stents after drug-eluting balloon treatment of the side branch: A simple and durable technique for treating bifurcation lesions
    McCutcheon, Keir
    Garda, Riaz
    Mkhwanazi, Lance
    Vachiat, Ahmed
    Ramjee, Rohan
    Moosa, Jameel
    Tsabedze, Nqoba
    Karolia, Saffiyah
    Manga, Pravin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 182 : 294 - 296
  • [32] Mechanisms of balloon angioplasty and repeat stenting in patients with drug-eluting in-stent restenosis
    Alfonso, Fernando
    Sandoval, Jorge
    Perez-Vizcayno, Maria J.
    Cardenas, Alberto
    Gonzalo, Nieves
    Jimenez-Quevedo, Pilar
    Ibanez, Borja
    Nunez-Gil, Ivan
    Rivero, Fernando
    Escaned, Javier
    Fernandez-Ortiz, Antonio
    Macaya, Carlos
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 178 : 213 - 220
  • [33] The incidence of stent fracture after drug-eluting stent implantation: comparison between de novo lesion and in-stent restenosis lesion
    Kanazawa, T.
    Kadota, K.
    Otsuru, S.
    Hasegawa, D.
    Habara, S.
    Tada, T.
    Tanaka, H.
    Fuku, Y.
    Goto, T.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2015, 36 : 481 - 482
  • [34] Safety and efficacy of drug-eluting stents combining biodegradable polymers with ultrathin stent platforms
    Iglesias, Juan F.
    Pilgrim, Thomas
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (01) : 2 - 4
  • [35] Evolution of Coronary Stent Platforms: A Brief Overview of Currently Used Drug-Eluting Stents
    Brami, Pierre
    Fischer, Quentin
    Pham, Vincent
    Seret, Gabriel
    Varenne, Olivier
    Picard, Fabien
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [36] The frequency of the Stent Fracture per Lesion: the Comparison between First and New Generation Drug-Eluting Stent
    Yagasaki, Hiroto
    Hyodo, Yusuke
    Otsuru, Suguru
    Hasegawa, Daiji
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Kadota, Kazushige
    Mitsudo, Kazuaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B236 - B237
  • [37] Incidence and characteristics of coronary aneurysm after drug-eluting stent implantation
    Rha, Seung-Woon
    Wani, Sunil P.
    Choi, Cheol Ong
    Suh, Soon Yong
    Kim, Eung Ju
    Kim, Jin Won
    Park, Chang Gyu
    Seo, Hong Seog
    Oh, Dong Joo
    CIRCULATION, 2006, 114 (18) : 731 - 731
  • [38] Difference of Tissue Characteristics of Restenosis Lesion Between Drug-Eluting Stent and Bare-Metal Stent: Optical Coherence Tomography Analysis
    Habara, Maoto
    Terashima, Mitsuyasu
    Nasu, Kenay
    Ko, Yoshihiro
    Ito, Tsuyoshi
    Ebisawa, Soichiro
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Ehara, Mariko
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Yasushi
    Kato, Osamu
    Suzuki, Takahiko
    CIRCULATION, 2010, 122 (21)
  • [39] A Comparison of the Mechanical Performance Characteristics of Seven Drug-Eluting Stent Systems
    Schmidt, W.
    Lanzer, P.
    Behrens, P.
    Topoleski, L. D. T.
    Schmitz, K. -P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (03) : 350 - 360
  • [40] Stent fracture associated with drug-eluting stents: Clinical characteristics and implications
    Lee, Michael S.
    Jurewitz, Daniel
    Aragon, Joseph
    Forrester, James
    Makkar, Raj R.
    Kar, Saibal
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) : 387 - 394