Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis

被引:15
|
作者
Ahamed, Shadir Bughari Basheer [1 ]
Vanajassun, Purushothaman Pranav [1 ]
Rajkumar, Kothandaraman [1 ]
Mahalaxmi, Sekar [1 ]
机构
[1] SRM Dent Coll, Dept Conservat Dent & Endodont, Madras 600089, Tamil Nadu, India
关键词
Bending stress; cross-sectional design; finite element analysis; nickel-titanium rotary; BENDING PROPERTIES; INSTRUMENTS; MODELS; RESISTANCE; FRACTURE;
D O I
10.1016/j.joen.2017.12.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. Methods: A 3-dimensional model of the simulated root canal with 45 curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 A). Results: The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. Conclusions: The CTU designed instruments showed the least bending stress on a 45 degrees angulated simulated root canal when compared with all the other tested designs.
引用
收藏
页码:654 / 658
页数:5
相关论文
共 50 条
  • [21] Influence of nickel-titanium rotary systems with varying tapers on the biomechanical behaviour of maxillary first premolars under occlusal forces: a finite element analysis study
    Ors, S. Askerbeyli
    Serper, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (05) : 529 - 540
  • [22] Influence of Different Heat Treatments on Torsional and Cyclic Fatigue Resistance of Nickel-Titanium Rotary Files: A Comparative Study
    Gambarini, Gianluca
    Cicconetti, Andrea
    Di Nardo, Dario
    Miccoli, Gabriele
    Zanza, Alessio
    Testarelli, Luca
    Seracchiani, Marco
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [23] Finite element study of the fatigue behaviour of nickel-titanium endodontic files utilised with pecking motion technique
    Kokan, Eyup Can
    Atik, Yasin
    Ozupek, Sebnem
    Podnos, Evgeny
    Erisen, Raif
    AUSTRALIAN ENDODONTIC JOURNAL, 2024, 50 (01) : 97 - 109
  • [24] Relation between laboratory cantilever bending test and finite element analysis of five different nickel-titanium rotary instruments
    Amira Galal Ismail
    Manar Galal
    Mohamed H. Zaazou
    Tamer M. Hamdy
    Rasha M. Abdelraouf
    Bulletin of the National Research Centre, 44 (1)
  • [25] A Comparative Computational Analysis of the Mechanical Behavior of Two Nickel-Titanium Rotary Endodontic Instruments
    Necchi, Silvia
    Petrini, Lorenza
    Taschieri, Silvio
    Migliavacca, Francesco
    JOURNAL OF ENDODONTICS, 2010, 36 (08) : 1380 - 1384
  • [26] Comparative analysis of mechanical properties of differently tapered nickel-titanium endodontic rotary instruments
    Fukumori, Yohei
    Nishijyo, Miki
    Tokita, Daisuke
    Miyara, Kana
    Ebihara, Arata
    Okiji, Takashi
    DENTAL MATERIALS JOURNAL, 2018, 37 (04) : 667 - 674
  • [27] Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis
    Kim, Hyeon-Cheol
    Shun-Pan, Gary
    Lee, Chan-Joo
    Kim, Byung-Min
    Park, Jeong-Kil
    Kang, Soon-Il
    JOURNAL OF ENDODONTICS, 2008, 34 (06) : 743 - 747
  • [28] Cryotherapy Treatment Effect on Heat-Treated Nickel-Titanium (NiTi) Rotary Single-File System: An In Vitro Comparative Study by Finite Element Analysis
    Chakaravarthy, Yadav
    Prasad, Vishnu
    Revankar, Vanita Dattatray
    Karthikeyan, Haripriya
    Saravanan, Suresh
    Santosh, Aishwarya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [29] Evaluation of fracture incidence of three rotary nickel-titanium files used in mechanical glide path: an in-vitro study
    Afifi, Aliaa Rifaat
    Zaazou, Ashraf Mamdouh
    Lehata, Nehal Adel
    ENDO-ENDODONTIC PRACTICE TODAY, 2019, 13 (01): : 31 - 39
  • [30] Cone Beam Computed Tomography Evaluation of Hand Nickel-Titanium K-Files and Rotary System in Primary Teeth
    Radhika, Etta
    Reddy, E. Rajendra
    Rani, S. Thabitha
    Kumar, Labishetty Vinay
    Manjula, M.
    Mohan, Tulluru Ajay
    PEDIATRIC DENTISTRY, 2017, 39 (04) : 319 - 323