Comparative Methods for Metal Artifact Reduction in x-ray CT

被引:0
|
作者
Abdoli, Mehrsima [1 ]
Mehranian, Abolfazl [2 ]
Ailianou, Angeliki [2 ]
Becker, Minerva [2 ]
Zaidi, Habib [2 ,3 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
基金
瑞士国家科学基金会;
关键词
ATTENUATION CORRECTION; COMPUTED-TOMOGRAPHY; ALGORITHM; IMPLANTS; INTERPOLATION; SINOGRAMS;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To assess the performance of five metal artefact reduction (MAR) techniques for the assessment of computed tomography (CT) images of patients with hip prostheses. Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projections in the sinogram, two-dimensional interpolation (2D), a normalized metal artefact reduction (NMAR) technique, a metal deletion technique (MDT), and a 3D prior image constrained projection completion approach (MAPC). The algorithms were applied to 10 simulated datasets as well as30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded, experienced radiologists, who ranked overall artefact severity, as well as pelvic organ recognition for each algorithm, respectively. The simulated studies revealed that 2D, NMAR and MAPC techniques performed almost equally well in regions with dark streaking artefacts. However, in regions with bright streaking artefacts, LI outperformed the other techniques (p < 0.05). Visual assessment of clinical datasets confirmed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Overall, all methods performed equally well in artefact-free regions. However, NMAR and MAPC outperformed the other techniques in regions affected by artefacts.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Multisource X-Ray System for Artifact Reduction in Cone Beam CT
    Becker, A.
    Hernandez, A.
    Schwoebel, P.
    Boone, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3178
  • [22] GPU-Accelerated Dynamic Wavelet Thresholding Algorithm for X-Ray CT Metal Artifact Reduction
    Peng, Chengtao
    Qiu, Bensheng
    Li, Ming
    Yang, Yang
    Zhang, Cheng
    Gong, Lun
    Zheng, Jian
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (01) : 17 - 26
  • [23] X-ray CT Metal Artifact Reduction Using Wavelet Domain L0 Sparse Regularization
    Mehranian, Abolfazl
    Ay, Mohammad Reza
    Rahmim, Arman
    Zaidi, Habib
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1707 - 1722
  • [24] Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT
    Hur, Jin
    Kim, Dongjoon
    Shin, Yeong-Gil
    Lee, Ho
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [25] 3D Prior Image Constrained Projection Completion for X-ray CT Metal Artifact Reduction
    Mehranian, Abolfazl
    Ay, Mohammad Reza
    Rahmim, Arman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3318 - 3332
  • [26] X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses
    Zhao, SY
    Roberston, DD
    Wang, G
    Whiting, B
    Bae, KT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) : 1238 - 1247
  • [27] Metal Artifact Reduction in X-ray CT Image Using Discriminant Analysis Method and Sin Curve Interpolation
    Inagaki, Keisuke
    Tanaka, Toshiyuki
    2017 56TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2017, : 894 - 897
  • [28] Assessment of metal artifact reduction methods in pelvic CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    MEDICAL PHYSICS, 2016, 43 (04) : 1588 - 1597
  • [29] A FRAMEWORK FOR SPECTRAL ARTIFACT CORRECTIONS IN X-RAY CT
    STONESTROM, JP
    ALVAREZ, RE
    MACOVSKI, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) : 128 - 141
  • [30] Streak Artifact Correction in X-ray CT Imaging
    Li B.-L.
    Mo Y.
    Zhang P.-Y.
    Li B.
    Zhang Y.-J.
    1600, Atomic Energy Press (51): : 2075 - 2078