Ultrasensitive detection of mercury (II) ions using electrochemical surface plasmon resonance with magneto hydrodynamic convection

被引:44
|
作者
Panta, Yogendra M. [2 ]
Liu, Jing [3 ]
Cheney, Marcos A. [4 ]
Joo, Sang W. [5 ]
Qian, Shizhi [1 ]
机构
[1] Old Dominion Univ, Dept Aerosp Engn, Norfolk, VA 23529 USA
[2] Youngstown State Univ, Dept Mech & Ind Engn, Youngstown, OH 44555 USA
[3] Huazhong Univ Sci & Technol, State Key Lab Coal Combust, Wuhan 430074, Peoples R China
[4] Univ Maryland Eastern Shore, Dept Nat Sci, Princess Anne, MD 21853 USA
[5] Yeungnam Univ, Sch Mech Engn, Kyongsan 712749, South Korea
基金
美国国家科学基金会;
关键词
Heavy-metal detection; Mercury (II); Cyclic voltammetry (CV); Surface plasmon resonance (SPR); Electrochemical method; MHD; IMAGING MEASUREMENTS; STRIPPING VOLTAMMETRY; REDOX ELECTROLYTE; PASTE ELECTRODE; DNA; HYBRIDIZATION; SPECTROSCOPY; ADSORPTION; SENSOR; FLOW;
D O I
10.1016/j.jcis.2009.02.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A high-precision technique that can detect mercury (11) ions down to 1 fM concentration in aqueous solutions is introduced. The technique combines the conventional electrochemical method, surface plasmon resonance (SPR), and magnetohydrodynamic (MHD) convection. Mercury ions are electroplated onto a gold SPR sensing surface, and then detected quantitatively by applying a potential scan with cyclic voltammetry. Both the SPR angular shift and the electrochemical current signal are recorded for identification and quantification of the mercury ions. The detection sensitivity is further enhanced by applying an MHD convection in the presence of a magnetic field, which does not require any moving parts intruding into the aqueous solution. The technique thus has a great advantage for small detection volume. In the presence of supporting electrolytes, 1 mM nitric acid and 10 mM potassium nitrate, Hg2+ ionic solutions with concentrations ranging from 1 fM to 1 mu M are tested under different magnetic flux densities of B = 0, 0.27, 0.53, and 0.71 T. The experimental results demonstrate that the stripping signals of the 1 fM to 1 mu M Hg2+ ions are enhanced by 10-60% with the flux density B = 0.71 T. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [21] Ultrasensitive detection of miRNA with an antimonene-based surface plasmon resonance sensor
    Xue, Tianyu
    Liang, Weiyuan
    Li, Yawen
    Sun, Yuanhui
    Xiang, Yuanjiang
    Zhang, Yupeng
    Dai, Zhigao
    Duo, Yanhong
    Wu, Leiming
    Qi, Kun
    Shiyananju, Bannur Nanjunda
    Zhang, Lijun
    Cui, Xiaoqiang
    Zhang, Han
    Bao, Qiaoliang
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [22] Analysis of electrochemical processes using surface plasmon resonance
    Iwasaki, Y
    Horiuchi, T
    Morita, M
    Niwa, O
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 50 (02) : 145 - 148
  • [23] Ultrasensitive detection of miRNA with an antimonene-based surface plasmon resonance sensor
    Tianyu Xue
    Weiyuan Liang
    Yawen Li
    Yuanhui Sun
    Yuanjiang Xiang
    Yupeng Zhang
    Zhigao Dai
    Yanhong Duo
    Leiming Wu
    Kun Qi
    Bannur Nanjunda Shivananju
    Lijun Zhang
    Xiaoqiang Cui
    Han Zhang
    Qiaoliang Bao
    Nature Communications, 10
  • [24] A novel ultrasensitive surface plasmon resonance-based nanosensor for nitrite detection
    Miao, Pandeng
    Liu, Zhongdong
    Guo, Jun
    Yuan, Ming
    Zhong, Ruibo
    Wang, Liping
    Zhang, Feng
    RSC ADVANCES, 2019, 9 (31): : 17698 - 17705
  • [25] Analysis of electrochemical processes using surface plasmon resonance
    Iwasaki, Y.
    Horiuchi, T.
    Morita, M.
    Niwa, O.
    Sensors and Actuators, B: Chemical, 1998, B50 (02): : 145 - 148
  • [26] Dual Gold-Nanoslit Electrodes for Ultrasensitive Detection of Antigen-Antibody Reactions in Electrochemical Surface Plasmon Resonance
    Lo, Shu-Cheng
    Wang, Sheng-Hann
    Chang, Ting-Wei
    Lee, Kuang-Li
    Chern, Ruey-Lin
    Wei, Pei-Kuen
    ACS SENSORS, 2022, 7 (09) : 2597 - 2605
  • [27] Electrochemical sensor for detection of mercury (II) ions in water using nanostructured bismuth hexagons
    Sandeep Gupta
    Rini Singh
    M. D. Anoop
    Vaibhav Kulshrestha
    Divesh N. Srivastava
    Kanad Ray
    S. L. Kothari
    Kamlendra Awasthi
    Manoj Kumar
    Applied Physics A, 2018, 124
  • [28] Electrochemical sensor for detection of mercury (II) ions in water using nanostructured bismuth hexagons
    Gupta, Sandeep
    Singh, Rini
    Anoop, M. D.
    Kulshrestha, Vaibhav
    Srivastava, Divesh N.
    Ray, Kanad
    Kothari, S. L.
    Awasthi, Kamlendra
    Kumar, Manoj
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2018, 124 (11):
  • [29] Detection of electrochemical enzymatic reactions by surface plasmon resonance measurement
    Iwasaki, Y
    Horiuchi, T
    Niwa, O
    ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1595 - 1598
  • [30] Ultrasensitive and selective gold film-based detection of mercury (II) in tap water using a laser scanning confocal imaging-surface plasmon resonance system in real time
    Zhang, Hongyan
    Yang, Liquan
    Zhou, Bingjiang
    Liu, Weimin
    Ge, Jiechao
    Wu, Jiasheng
    Wang, Ying
    Wang, Pengfei
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 391 - 395