Quantum dots and p-phenylenediamine based method for the sensitive determination of glucose

被引:12
|
作者
Lv, Xiaoxiao [1 ]
Wang, Xiaoyu [1 ,2 ]
Huang, Dawei [1 ]
Niu, Chenggang [1 ]
Zeng, Guangming [1 ]
Niu, Qiuya [1 ]
机构
[1] Hunan Univ, Minist Educ, Key Lab Environm Biol & Pollut Control, Coll Environm Sci & Engn, Changsha 410082, Hunan, Peoples R China
[2] Xinxiang Univ, Coll Chem & Chem Engn, Xinxiang 453003, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose; p-phenylenediamine; Quantum dots; Time-gated fluorescence; Glucose oxidase; HYDROGEN-PEROXIDE; OPTICAL-DETECTION; OXIDASE; IMMOBILIZATION; NANOPARTICLES; PROBE; FE3O4;
D O I
10.1016/j.talanta.2014.04.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By introducing p-phenylenediamine (PPD) to the hybrid system of Mn-doped CdS/ZnS quantum dots (QDs) and glucose oxidase (GOD), a sensitive label-free method was proposed for direct detection of glucose. With glucose and PPD as substrates, 2,5-diamino-N,N'-di-(4-aminophenyl)-2,5-cyclohexadiene-1,4-diimine (DDACD) that intensively quenches the fluorescence of QDs can be produced by the catalysis of GOD. A detection limit as low as 3.2 mu M was obtained with the high-efficient fluorescence quencher. Two linear ranges, from 5.0 mu M to 1000 mu M and from 1.0 mu M to 10.0 mu M, were identified between time-gated fluorescence intensity and the concentration of glucose. It is shown that the newly proposed methods have high selectivity for glucose over other saccharides and coexisting biological species in serum. The method can be used directly to determine glucose in normal adult human serum without any complicated sample pretreatments. The recovery rate and repeatability of the method were also shown to be satisfactory. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [31] Synthesis of Ag NPs layer and its application as SERS substrate in the determination of p-phenylenediamine
    Yu, Qizhi
    Kong, Xiangfa
    Chen, Chaoshu
    Kang, Caiyan
    Meng, Mianwu
    Huang, Siyu
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2021, 25 (02) : 683 - 688
  • [32] Quantum dots (QDs) based fluorescence probe for the sensitive determination of kaempferol
    Tan, Xuanping
    Liu, Shaopu
    Shen, Yizhong
    He, Youqiu
    Yang, Jidong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 133 : 66 - 72
  • [33] Dual-mode colorimetric and fluorescent detection of cobalt ions based on N, B co-doped carbon quantum dots and p-phenylenediamine derived nanoparticles
    Anqi Hu
    Guoqing Chen
    Lei Li
    Chaoqun Ma
    Taiqun Yang
    Hui Gao
    Jiao Gu
    Chun Zhu
    Yamin Wu
    Microchimica Acta, 2024, 191
  • [34] Determination of Glucose Based on Carbon Quantum Dots as Peroxidase Mimetic Enzyme
    Zhong Qing-Mei
    Huang Xin-Hong
    Qin Qing-Min
    Su An-Mei
    Chen Yu-Ye
    Liu Xin-Yu
    Wang Yi-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (07) : 1062 - 1068
  • [35] Sensitive electrocatalytic determination of p-phenylenediamine using bimetallic nanocomposite of Cu-Ag nanoalloy and ionic liquid-graphene oxide
    Singh, Manorama
    Bhardiya, Smita R.
    Asati, Ambika
    Sheshma, Harendra
    Rai, Vijai K.
    Rai, Ankita
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 894
  • [36] β-Ketoenamine-based covalent organic framework for detection and removal of p-phenylenediamine
    Li, Lihua
    Ma, Yinghu
    Ou, Weizhi
    Yang, Haohao
    Yang, Xiaomei
    MICROPOROUS AND MESOPOROUS MATERIALS, 2024, 375
  • [37] Graphene quantum dots as a new substrate for immobilization and direct electrochemistry of glucose oxidase: Application to sensitive glucose determination
    Razmi, Habib
    Mohammad-Rezaei, Rahim
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 498 - 504
  • [38] Dual-readout immunoassay based on IFE and p-phenylenediamine for detection of zearalenone
    Wu, Shixiang
    Zhao, Yanan
    Xiao, Yao
    Ma, Liyuan
    Zhang, Qi
    Li, Peiwu
    Yang, Hualin
    Zhou, Yu
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 132
  • [39] Lead determination by anodic stripping voltammetry using a p-phenylenediamine modified carbon paste electrode
    Adraoui, I
    El Rhazi, M
    Amine, A
    Idrissi, L
    Curulli, A
    Palleschi, G
    ELECTROANALYSIS, 2005, 17 (08) : 685 - 693
  • [40] The electrochemical copolymerization of diphenylamine and p-phenylenediamine and its use as a modified electrode for amperometric determination of iodate
    Tabrizi, Mahmoud Amouzadeh
    Ebrahimi, Leila