Dioxin and NOx control using pilot-scale pulsed corona plasma technology

被引:7
|
作者
Obata, S [1 ]
Fujihira, H [1 ]
机构
[1] Takuma Co Ltd, Takasago, Hyogo 676, Japan
关键词
air pollution control; dioxin; DeNO(x); non-thermal plasma; pulse charge; rotary spark gap;
D O I
10.1080/00102209808952023
中图分类号
O414.1 [热力学];
学科分类号
摘要
We carried out tests on certain incinerator plant for two years from 1993 through 1994, to assure the effect of pulsed corona discharge for removal of NOx and dioxin in hue gas in the small-scale experimental apparatus. The gas volume of the test plant is 50 NM3/H. By the experiment, high performance of dioxin removal at the gas temperature of 150 degrees C was achieved. Regarding NOx, the reduction efficiency of NO was about 60 percents, whereas that of NOx including NO2 was 30 percents at most.
引用
收藏
页码:3 / 11
页数:9
相关论文
共 50 条
  • [21] A pilot-scale microwave technology for sludge sanitization and drying
    Mawioo, Peter M.
    Garcia, Hector A.
    Hooijmans, Christine M.
    Velkushanova, Konstantina
    Simonic, Marjana
    Mijatovic, Ivan
    Brdjanovic, Damir
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 601 : 1437 - 1448
  • [22] Performance Characteristics of Pilot-Scale Indirect Plasma and Chemical System Used for the Removal of NOx From Boiler Emission
    Fujishima, Hidekatsu
    Kuroki, Tomoyuki
    Ito, Tomohiro
    Otsuka, Keiichi
    Yamamoto, Toshiaki
    Yoshida, Keiichiro
    Okubo, Masaaki
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (05) : 1707 - 1714
  • [23] Evaluation of a pilot-scale biotrickling filter as a VOC control technology for the plastic coating sector
    Alvarez-Hornos, F. J.
    Lafita, C.
    Martinez-Soria, V.
    Penya-Roja, J. M.
    Perez, M. C.
    Gabaldon, C.
    BIOCHEMICAL ENGINEERING JOURNAL, 2011, 58-59 : 154 - 161
  • [24] A Pilot-Scale Experiment for Total Marine Diesel Emission Control Using Ozone Injection and Nonthermal Plasma Reduction
    Kuwahara, Takuya
    Yoshida, Keiichiro
    Hanamoto, Kenichi
    Sato, Kazutoshi
    Kuroki, Tomoyuki
    Okubo, Masaaki
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (02) : 1168 - 1178
  • [25] Pilot-Scale Experiment of Total Marine Diesel Emission Control Using Ozone Injection and Nonthermal Plasma Reduction
    Kuwahara, Takuya
    Kuroki, Tomoyuki
    Okubo, Masaaki
    Yoshida, Keiichiro
    Hanamoto, Kenichi
    Sato, Kazutoshi
    2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [26] Low-level NOx removal in ambient air by pulsed corona technology
    Beckers, F. J. C. M.
    Hoeben, W. F. L. M.
    Pemen, A. J. M.
    van Heesch, E. J. M.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (29)
  • [27] Hospital Wastewater Treatment with Pilot-Scale Pulsed Corona Discharge for Removal of Pharmaceutical Residues (vol 6, pg 1569, 2018)
    不详
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (02): : A1 - A1
  • [28] SURFACE DECONTAMINATION OF WHOLE CHICKEN CARCASSES USING A PILOT-SCALE PULSED UV LIGHT SYSTEM
    Keklik, N. M.
    Demirci, A.
    Bock, R. G.
    TRANSACTIONS OF THE ASABE, 2011, 54 (03) : 993 - 1000
  • [29] Simulation and evaluation of pilot-scale pulsed electric field (PEF) processing
    Buckow, Roman
    Schroeder, Stefanie
    Berres, Paul
    Baumann, Pascal
    Knoerzer, Kai
    JOURNAL OF FOOD ENGINEERING, 2010, 101 (01) : 67 - 77
  • [30] Innovative NOx reduction from cement kiln and pilot-scale experimental verification
    Cai, Jun
    Wu, Huixing
    Ren, Qiangqiang
    Lin, Li
    Zhou, Tuo
    Lyu, Qinggang
    FUEL PROCESSING TECHNOLOGY, 2020, 199