AN EXPERIMENTAL STUDY ON THERMOELECTRIC HEAT PUMP WATER HEATER

被引:0
|
作者
Zhang, Ling [1 ]
Liu, Zhongbing [1 ]
Yang, Zhiang [1 ]
Xu, Min [1 ]
Han, Tianhe [1 ]
机构
[1] Hunan Univ, Dept Bldg Environm & Serv Engn, Changsha 410082, Hunan, Peoples R China
关键词
Thermoelectric heat pump; Water heater; Temperature difference; Coefficient of performance; SYSTEM;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents results of tests carried out to investigate the performance of the thermoelectric heat pump water heater. The work involved design and construction of a thermoelectric heat pump water heater. The performance of the thermoelectric heat pump water heater was investigated under different conditions. The experiment results show that when the temperature of water is not too high, the higher the operating voltage is, the larger the temperature difference between the hot and cold sides becomes and a smaller coefficient of performance is, however, when the temperature of water increases to a certain level, the higher the operating voltage is, the larger the coefficient of performance becomes. The temperature difference between the hot and cold sides becomes larger and the coefficient of performance decreases with the increase of the temperature of water. And when the temperature of water increases to a certain level, the temperature of cold sides becomes higher than the temperature of the environment, indicating that the thermoelectric heat pump loses the capability of absorbing heat from environment. Under an operating voltage of 16V and an ambient temperature of 25 degrees C, the coefficient of performance decreases from 1.51 to 1.06 when the temperature increases from 24 degrees C to 44 degrees C. These results can provide guides for the design and application of the thermoelectric heat pump water heater.
引用
收藏
页码:2163 / 2170
页数:8
相关论文
共 50 条
  • [1] Experimental study on thermoelectric heat pump low-temperature water heater
    Xie, Kangshan
    Yu, Jianlin
    Zhao, Hua
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2007, 41 (11): : 1338 - 1341
  • [2] Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens
    LIU ZhongbingZHANG LingYANG ZhangXU MingHAN TianheCollege of Civil EngineeringHunan UniversityChangshaHunan China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 131 - 135
  • [3] Experimental study of thermoelectric heat pump water heater with exhaust heat recovery from kitchens
    College of Civil Engineering, Hunan University, Changsha 410082, China
    Hunan Daxue Xuebao, 2009, SUPPL. (131-135):
  • [5] Investigation on a thermoelectric heat pump storage water heater
    Mo, Zhi-Jiao
    Zhang, Ling
    Liu, Zhong-Bing
    Xu, Min
    Zhang, Xiao-Jie
    Chen, You-Ming
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 129 - 132
  • [6] Analysis and experimental study on ground source heat pump water heater
    Li Shu-hong
    Shan Kui
    Zhang Xiao-song
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 258 - 262
  • [7] Study on the performance of a novel thermoelectric heat pump air heater
    Zhang, Ling
    Meng, Fang-Fang
    Liu, Zhong-Bing
    Luo, Yong-Qiang
    Xie, Lei
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2015, 42 (09): : 124 - 127
  • [8] A novel water heater integrating thermoelectric heat pump with separating thermosiphon
    Luo, QH
    Tang, GF
    Liu, ZQ
    Wang, JW
    APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) : 2193 - 2203
  • [9] Experimental study on CO 2 air source heat pump water heater
    Chen Q.
    Tong Y.
    Zhu Z.-J.
    Tang L.-M.
    Chen G.-M.
    Li J.-J.
    Chen, G.-M. (gmchen@zju.edu.cn), 1600, Zhejiang University (46): : 610 - 615
  • [10] Numerical and experimental study on heat pump water heater with PCM for thermal storage
    Long, Jian-You
    Zhu, Dong-Sheng
    ENERGY AND BUILDINGS, 2008, 40 (04) : 666 - 672