Development of a novel, fast, sensitive method for chromium speciation in wastewater based on an organic polymer as solid phase extraction material combined with HPLC-ICP-MS
被引:38
|作者:
Jia, Xiaoyu
[1
,2
]
Gong, Dirong
[3
]
Xu, Bin
[1
]
Chi, Qiaoqiao
[1
]
Zhang, Xian
[1
]
机构:
[1] Chinese Acad Sci, Inst Urban Environm, Key Lab Urban Environm & Hlth, Xiamen 361021, Peoples R China
[2] Chinese Acad Sci, Ning Bo Urban Environm Observat & Res Stn, Ningbo 315830, Zhejiang, Peoples R China
[3] Ningbo Univ, Fac Mat Sci & Chem Engn, Dept Polymer Sci & Engn, Ningbo 315211, Zhejiang, Peoples R China
来源:
关键词:
Chromium;
HPLC;
ICP-MS;
Speciation;
Solid phase extraction;
Wastewater;
PLASMA-MASS SPECTROMETRY;
ATOMIC-ABSORPTION-SPECTROMETRY;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
ENVIRONMENTAL-SAMPLES;
CR(VI);
CELL;
PRECONCENTRATION;
SELENIUM;
CR(III);
COLUMN;
D O I:
10.1016/j.talanta.2015.09.047
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Speciation analysis of inorganic chromium in wastewater is of great significance for the monitoring of environmental pollution. In this work, N,N-bis(2-aminoethyl)ethane-1,2-diamine functionalized poly (chloromethyl styrene-co-styrene) was synthesized, characterized and used as the adsorbent to pre-concentrate chromium species in environmental waters by on line solid-phase extraction (SPE). The trace speciation analysis of Cr(III) and Cr(VI) in wastewater has been used by short-column high-performance liquid chromatography hyphenated to inductively coupled plasma spectrometry (HPLC-ICP-MS) after online SPE. Cr(III) and Cr(VI) have been adsorbed on the anion exchange column after transforming the cationic Cr(III) to an anionic [Cr(III)-EDTA](-) complex devoid of re-dox reagent, and then eluted rapidly (within seconds) with a very low concentration of tetrabutylammonium hydroxide (TBAH) solution. This method provides a reliable on-line preconcentration method and detection coupled technique. Under the optimized conditions, high enrichment factors have been obtained for Cr(VI) and [Cr(III)-EDTA](-) with 30 mL sample solution up to 105 and 128, respectively. The low detection limits of 0.0068 ng mL1 and 0.0041 ng mL(-1), with the relative standard deviations (RSDs) of 43% and 3.6% were obtained for Cr(VI) and [Cr(III)-EDTA]-, respectively. The developed method was validated by analyzing Certified Reference Materials GSBZ50027-94, and the spike tests were also performed. At the same time, thanks to the merit of simple operation, rapid adsorption/desorption dynamics, high enrichment and low LODs, the established method was applied to analyze three wastewater samples from different discharge port. (C) 2015 Elsevier B.V. All rights reserved.