In situ rapid magnetic solid-phase extraction coupled with HPLC-ICP-MS for mercury speciation in environmental water

被引:53
|
作者
Zhang, Shengxiao [1 ,2 ]
Luo, Hao [1 ]
Zhang, Yuanyuan [1 ]
Li, Xiaoyan [1 ]
Liu, Junshen [1 ]
Xu, Qiang [1 ]
Wang, Zhenhua [2 ]
机构
[1] Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Peoples R China
[2] Shandong Acad Sci, Shandong Anal & Tester Ctr, Jinan, Peoples R China
基金
中国国家自然科学基金;
关键词
Fe3O4; nanoparticle; Thiol groups; Magnetic solid-phase extraction; Mercury speciation; OPTICAL EMISSION-SPECTROMETRY; TOXIC METAL-IONS; SELECTIVE EXTRACTION; NANOPARTICLES; SAMPLES; PRECONCENTRATION; POLLUTANTS; REMOVAL;
D O I
10.1016/j.microc.2015.11.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
SiO2 was coated on the surface of Fe3O4 nanoparticles through hydrolyzation of Na2SiO3, and then thiol groups were modified on SiO2 by silanization reaction to form Fe3O4@SiO2-SH sorbents. Due to high affinity between thiol group and mercury, the Fe3O4@SiO2-SH was applied as magnetic sorbent for in situ extraction and stabilization of trace mercury species from natural water. Trace Hg2+ and methylmercury in 500 mL of water sample could be almost recovered with only 60 mg sorbents. Magnetic separation and rapid adsorption equilibrium greatly simplified extraction procedure and shortened analysis time. Solution pH had no obvious effect on mercury recoveries in the range of 3-9. The loaded Hg2+ and methylmercury were readily desorbed with 2.5 mL of 0.5 mol L-1 HCl containing 1% thiourea. The mercury speciation in eluate was acquired by using high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS). The detection limits of the present method for Hg2+ and methylmercury were 1.0 and 0.3 ng L-1, respectively. The recoveries of spiked water samples were in the range of 96%-104% with relative standard deviations varying from 0.2% to 4.2%, showing good accuracy of the method. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [1] Speciation of mercury in water and fish samples by HPLC-ICP-MS after magnetic solid phase extraction
    Zhu, Siqi
    Chen, Beibei
    He, Man
    Huang, Tong
    Hu, Bin
    TALANTA, 2017, 171 : 213 - 219
  • [2] Simultaneous enrichment and speciation of lead and mercury by magnetic solid-phase extraction coupled to HPLC-ICP-MS based on magnetic hydrazine-linked covalent organic frameworks
    Zhang, Xiaolai
    Li, Fangli
    Chao, Jingbo
    Li, Zhicai
    Zhang, Guimin
    Zhai, Lihai
    Hu, Ligang
    Jiao, Heping
    Wang, Zhenhua
    ANALYTICA CHIMICA ACTA, 2024, 1307
  • [3] Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction
    Chen, Beibei
    Hu, Bin
    He, Man
    Huang, Qian
    Zhang, Yuan
    Zhang, Xing
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (03) : 334 - 343
  • [4] Speciation analysis of silver sulfide nanoparticles in environmental waters by magnetic solid-phase extraction coupled with ICP-MS
    Zhou, Xiaoxia
    Liu, Jingfu
    Yuan, Chungang
    Chen, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2285 - 2292
  • [5] The extraction and speciation of arsenic in rice flour by HPLC-ICP-MS
    Narukawa, Tomohiro
    Inagaki, Kazumi
    Kuroiwa, Takayoshi
    Chiba, Koichi
    TALANTA, 2008, 77 (01) : 427 - 432
  • [6] Semiautomatic method for the ultra-trace arsenic speciation in environmental and biological samples via magnetic solid phase extraction prior to HPLC-ICP-MS determination
    Montoro-Leal, P.
    Garcia-Mesa, J. C.
    Morales-Benitez, I
    Garcia de Torres, A.
    Vereda Alonso, E.
    TALANTA, 2021, 235 (235)
  • [7] Zwitterion-functionalized polymer microspheres-based solid phase extraction method on-line combined with HPLC-ICP-MS for mercury speciation
    Jia, Xiaoyu
    Zhao, Junyi
    Ren, Hongyun
    Wang, Jiani
    Hong, Zixiao
    Zhang, Xian
    TALANTA, 2019, 196 : 592 - 599
  • [8] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Sun, Peng
    Gao, Yuling
    Lian, Yongfu
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (07) : 1483 - 1489
  • [9] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Peng Sun
    Yuling Gao
    Yongfu Lian
    Journal of the Iranian Chemical Society, 2019, 16 : 1483 - 1489
  • [10] Review on Toxic Metal Speciation Analysis Based on Coupled Technique HPLC-ICP-MS (Environmental Aspects).
    Shoaib, Muhammad
    Al-Swaidan, Hassan Mohammad
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (06): : 1585 - 1593