Vented versus unvented chest seals for treatment of pneumothorax and prevention of tension pneumothorax in a swine model

被引:24
|
作者
Kheirabadi, Bijan S. [1 ]
Terrazas, Irasema B. [1 ]
Koller, Alexandra [1 ]
Allen, Paul B. [1 ]
Klemcke, Harold G. [1 ]
Convertino, Victor A. [1 ]
Dubick, Michael A. [1 ]
Gerhardt, Robert T. [1 ]
Blackbourne, Lorne H. [1 ]
机构
[1] US Army Inst Surg Res, San Antonio, TX USA
来源
关键词
Pneumothorax; chest seals; tension pneumothorax; combat casualty care; swine; COMBAT CASUALTIES;
D O I
10.1097/TA.0b013e3182988afe
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Unvented chest seals (CSs) are currently recommended for the management of penetrating thoracic injuries in the battlefield. Since no supporting data exist, we compared the efficacy of a preferred unvented with that of a vented CS in a novel swine model of pneumothorax (PTx). METHODS: An open chest wound was created in the left thorax of spontaneously air-breathing anesthetized pigs (n = 8). A CS was applied over the injury, then tension PTx was induced by incremental air injections (0.2 L) into the pleural cavity via a cannula that was also used to measure intrapleural pressure (IP). Both CS were tested on each pig in series. Tidal volume (V-T), respiratory rate, IP, heart rate, mean arterial pressure, cardiac output, central venous pressure, pulmonary arterial pressure, venous and peripheral oxygen saturations (SvO(2), SpO(2)) were recorded. Tension PTx was defined as a mean IP equal to or greater than + 1 mm Hg plus significant (20-30%) deviation in baseline levels of the previously mentioned parameters and confirmed by chest x-ray study. PaO2 and PaCo2 were also measured. RESULTS: PTx produced immediate breathing difficulty and significant rises in IP and pulmonary arterial pressure and falls in V-T, SpO(2), and SvO(2). Both CSs returned these parameters to near baseline within 5 minutes of application. After vented CS was applied, serial air injections up to 2 L resulted in no significant change in the previously mentioned parameters. After unvented CS application, progressive deterioration of all respiratory parameters and onset of tension PTx were observed in all subjects after approximately 1.4-L air injection. CONCLUSION: Both vented and unvented CSs provided immediate improvements in breathing and blood oxygenation in our model of penetrating thoracic trauma. However, in the presence of ongoing intrapleural air accumulation, the unvented CS led to tension PTx, hypoxemia, and possible respiratory arrest, while the vented CS prevented these outcomes. (J Trauma Acute Care Surg. 2013; 75: 150-156. Copyright (C) 2013 by Lippincott Williams & Wilkins)
引用
下载
收藏
页码:150 / 156
页数:7
相关论文
共 50 条
  • [1] VENTED CHEST SEALS FOR PREVENTION OF TENSION PNEUMOTHORAX IN A COMMUNICATING PNEUMOTHORAX
    Kotora, Joseph G., Jr.
    Henao, Jose
    Littlejohn, Lanny F.
    Kircher, Sara
    JOURNAL OF EMERGENCY MEDICINE, 2013, 45 (05): : 686 - 694
  • [2] Evaluation of an Artificial Intelligence Model for Detection of Pneumothorax and Tension Pneumothorax in Chest Radiographs
    Hillis, James M.
    Bizzo, Bernardo C.
    Mercaldo, Sarah
    Chin, John K.
    Newbury-Chaet, Isabella
    Digumarthy, Subba R.
    Gilman, Matthew D.
    Muse, Victorine V.
    Bottrell, Georgie
    Seah, Jarrel C. Y.
    Jones, Catherine M.
    Kalra, Mannudeep K.
    Dreyer, Keith J.
    JAMA NETWORK OPEN, 2022, 5 (12)
  • [3] Adherence evaluation of vented chest seals in a swine skin model
    Arnaud, Francoise
    Maudlin-Jeronimo, Eric
    Higgins, Adam
    Kheirabadi, Bijan
    McCarron, Richard
    Kennedy, Daniel
    Housler, Greggory
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (10): : 2097 - 2104
  • [4] An Evaluation of a Novel Medical Device Versus Standard Interventions in the Treatment of Tension Pneumothorax in a Swine Model (Sus scrofa)
    Sheldon, Rowan R.
    Do, Woo S.
    Forte, Dominic M.
    Weiss, Jessica B.
    Derickson, Michael J.
    Eckert, Matthew J.
    Martin, Matthew J.
    MILITARY MEDICINE, 2020, 185 (1-2) : 125 - 130
  • [5] TREATMENT OF TENSION PNEUMOTHORAX
    MACARTHUR, AM
    LANCET, 1960, 2 (NOV26): : 1201 - 1201
  • [6] TREATMENT OF TENSION PNEUMOTHORAX
    MACARTHUR, A
    LANCET, 1961, 1 (716): : 173 - &
  • [7] TREATMENT OF TENSION PNEUMOTHORAX
    FOSTERCARTER, AF
    LANCET, 1960, 2 (DEC10): : 1301 - 1302
  • [8] Evaluation of a novel thoracic entry device versus needle decompression in a tension pneumothorax swine model
    Kuckelman, John
    Derickson, Mike
    Phillips, Cody
    Barron, Morgan
    Marko, Shannon
    Eckert, Matthew
    Martin, Matthew
    AMERICAN JOURNAL OF SURGERY, 2018, 215 (05): : 832 - 835
  • [9] Polytrauma with tension pneumothorax with inserted chest tube
    Genzwürker, HV
    Volz, A
    Isselhorst, C
    Gieser, R
    Neufang, T
    Roth, H
    Birmelin, M
    Kerger, H
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2005, 40 (12): : 756 - 761
  • [10] TREATMENT OF TENSION CAVITIES WITH PNEUMOTHORAX
    BOBROWITZ, ID
    DISEASES OF THE CHEST, 1947, 13 (02): : 133 - 150