Accuracy of transvaginal ultrasound for diagnosis of deep endometriosis in uterosacral ligaments, rectovaginal septum, vagina and bladder: systematic review and meta-analysis

被引:161
|
作者
Guerriero, S. [1 ]
Ajossa, S. [1 ]
Minguez, J. A. [2 ]
Jurado, M. [2 ]
Mais, V. [1 ]
Melis, G. B. [1 ]
Alcazar, J. L. [2 ]
机构
[1] Univ Cagliari, Policlin Univ Duilio Casula, Dept Obstet & Gynecol, I-09042 Cagliari, Italy
[2] Univ Navarra, Sch Med, Clin Univ Navarra, Dept Obstet & Gynecol, E-31080 Pamplona, Spain
关键词
bladder endometriosis; deep endometriosis; meta-analysis; rectovaginal septum; systematic review; transvaginal ultrasound; uterosacral ligaments; vaginal endometriosis; RECTAL ENDOSCOPIC SONOGRAPHY; INFILTRATING ENDOMETRIOSIS; PELVIC ENDOMETRIOSIS; MAGNETIC-RESONANCE; CLINICAL EXAMINATION; WATER-CONTRAST; ULTRASONOGRAPHY; PREDICTION; SEVERITY; SONOVAGINOGRAPHY;
D O I
10.1002/uog.15667
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To review the diagnostic accuracy of transvaginal ultrasound (TVS) in the preoperative detection of endometriosis in the uterosacral ligaments (USL), rectovaginal septum (RVS), vagina and bladder in patients with clinical suspicion of deep infiltrating endometriosis (DIE). Methods An extensive search was performed in MEDLINE (PubMed) and EMBASE for studies published between January 1989 and December 2014. Studies were considered eligible if they reported on the use of TVS for the preoperative detection of endometriosis in the USL, RVS, vagina and bladder in women with clinical suspicion of DIE using the surgical data as a reference standard. Study quality was assessed using the PRISMA guidelines and QUADAS-2 tool. Results Of the 801 citations identified, 11 studies (n= 1583) were considered eligible and were included in themeta-analysis. For detection of endometriosis in the USL, the overall pooled sensitivity and specificity of TVS were 53% (95% CI, 35-70%) and 93% (95% CI, 83-97%), respectively. The pretest probability of USL endometriosis was 54%, which increased to 90% when suspicion of endometriosis was present after TVS examination. For detection of endometriosis in the RVS, the overall pooled sensitivity and specificity were 49% (95% CI, 36-62%) and 98% (95% CI, 95-99%), respectively. The pretest probability of RVS endometriosis was 24%, which increased to 89% when suspicion of endometriosis was present after TVS examination. For detection of vaginal endometriosis, the overall pooled sensitivity and specificity were 58% (95% CI, 40-74%) and 96% (95% CI, 87-99%), respectively. The pretest probability of vaginal endometriosis was 17%, which increased to 76% when suspicion of endometriosis was present after TVS assessment. Substantial heterogeneity was found for sensitivity and specificity for all these locations. For detection of bladder endometriosis, the overall pooled sensitivity and specificity were 62% (95% CI, 40-80%) and 100% (95% CI, 97-100%), respectively. Moderate heterogeneity was found for sensitivity and specificity for bladder endometriosis. The pretest probability of bladder endometriosis was 5%, which increased to 92% when suspicion of endometriosis was present after TVS assessment. Conclusion Overall diagnostic performance of TVS for detecting DIE in uterosacral ligaments, rectovaginal septum, vagina and bladder is fair with high specificity. Copyright (C) 2015 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:534 / 545
页数:12
相关论文
共 50 条
  • [21] Accuracy of Transvaginal Ultrasound Compared to Cystoscopy in the Diagnosis of Bladder Endometriosis Nodules
    Ros, Cristina
    de Guirior, Cristian
    Rius, Mariona
    Escura, Silvia
    Martinez-Zamora, Maria Angeles
    Gracia, Meritxell
    Peri, Lluis
    Franco, Agustin
    Carmona, Francisco
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (08) : 1571 - 1578
  • [22] A systematic review of the accuracy of ultrasound in the diagnosis of endometriosis
    Moore, J
    Copley, S
    Morris, J
    Lindsell, D
    Golding, S
    Kennedy, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 20 (06) : 630 - 634
  • [23] Transvaginal ultrasound and magnetic resonance imaging in the diagnosis of endometrioma: a systematic review and meta-analysis of diagnostic test accuracy studies
    Kanti, Fleur Serge
    Savard, Rose Gorak
    Bergeron, Frederic
    Zomahoun, Herve Tchala Vignon
    Netter, Antoine
    Maheux-Lacroix, Sarah
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2024, 44 (01)
  • [24] Ultrasound for the diagnosis of testicular torsion: a systematic review and meta-analysis of diagnostic accuracy
    Alexander, C. E.
    Light, A.
    Chan, V
    Asif, A.
    Clement, K.
    Warren, H.
    Zimmermann, E.
    Khadouri, S.
    Eyskens, P.
    Takwoingi, Y.
    Sidhu, P.
    Shah, T.
    Kasivisvanathan, V
    EUROPEAN UROLOGY, 2024, 85 : S41 - S41
  • [25] Diagnostic test accuracy of ultrasound for sarcopenia diagnosis: A systematic review and meta-analysis
    Fu, Hongbo
    Wang, Lei
    Zhang, Wenyi
    Lu, Jing
    Yang, Ming
    JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2023, 14 : 57 - 70
  • [26] Comparison of physical examination, ultrasound techniques and magnetic resonance imaging for the diagnosis of deep infiltrating endometriosis: A systematic review and meta-analysis of diagnostic accuracy studies
    Zhang, Xiao
    He, Tao
    Shen, Wen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (04) : 3208 - 3220
  • [27] Diagnostic accuracy of transvaginal ultrasound examination for local staging of cervical cancer: a systematic review and meta-analysis
    Tian, Yu
    Luo, Hong
    MEDICAL ULTRASONOGRAPHY, 2022, 24 (03) : 348 - 355
  • [28] Prospective diagnostic test accuracy of transvaginal ultrasound posterior approach for uterosacral ligament and torus uterinus deep endometriosis
    Freger, S. M.
    Turnbull, V.
    Mcgowan, K.
    Leonardi, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2024, 63 (02) : 263 - 270
  • [29] Diagnostic performance of transvaginal sonography vs. magnetic resonance imaging for rectovaginal septum deep in filtrating endometriosis: a head-to-head comparative meta-analysis
    Lou, Y.
    Li, D.
    Yu, J.
    Chen, J.
    Jin, X.
    CLINICAL RADIOLOGY, 2024, 79 (08) : 618 - 627
  • [30] Meta-analysis and systematic review to determine the optimal imaging modality for the detection of bladder deep endometriosis
    Gerges, B.
    Li, W.
    Leonardi, M.
    Mol, B. W.
    Condous, G.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 261 : 124 - 133