Axial features in the fouling of hollow-fibre membranes

被引:46
|
作者
Carroll, T [1 ]
Booker, NA [1 ]
机构
[1] CSIRO Mol Sci, Clayton S MDC, Vic 3169, Australia
关键词
hollow fibre; fouling; hydrodynamics; microfiltration;
D O I
10.1016/S0376-7388(99)00319-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The use of a hollow-fibre membrane for microfiltration introduces axial features which have important implications for both module design and fouling behaviour. The rate and mechanism of fouling of these fibres depend on their length and diameter. In this paper, the effect of fibre length on fouling behaviour is investigated. Axial features play a key role in the initial stages of fouling, but become less significant as permeate flowrates decline substantially. The rate of fouling is initially insensitive to fibre length, but as fouling progresses, longer fibres foul more slowly. After substantial fouling, the rate of fouling becomes dependent on membrane surface area, as might be expected from a planar membrane. A simple model is presented which isolates the contribution to fouling due to axial features arising from hollow-fibre geometry. This model predicts the experimentally-observed dependence of fouling behaviour on fibre dimensions under conditions where axial features are significant. Although, properties of the feed material (such as particle size, size distribution, cake permeability and compressibility) and transport phenomena (such as inertial lift and back-diffusion) may be key contributors to membrane fouling, the decline in permeate flowrate is dominated by axial features until substantial fouling has occurred. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:203 / 212
页数:10
相关论文
共 50 条
  • [41] Protein transport in packed bed ultrafiltration hollow-fibre bioreactors
    Koska, J
    Bowen, BD
    Piret, JM
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (14) : 2251 - 2263
  • [42] Hollow-fibre Based Microextraction and Voltammetric Determination of Vanillylmandelic Acid
    Hrdlicka, Vojtech
    Barek, Jin
    Navratil, Tomas
    XXXVII MODERNI ELEKTROCHEMICKE METODY, 2017, : 66 - 70
  • [43] Preparation and characterisation of Cibacron Blue F3G-A poly(ethylene) hollow-fibre affinity membranes
    F.J. Wolman
    M. Grasselli
    E.E. Smolko
    O. Cascone
    Biotechnology Letters, 2000, 22 : 1407 - 1411
  • [44] Effect of some spinning parameters and after-spinning processing regimes on the separating characteristics of hollow-fibre membranes
    A. A. Lysov
    S. A. Rashevskii
    A. V. Varezhkin
    Fibre Chemistry, 1998, 30 : 98 - 102
  • [45] Innovating dialysis through computational modelling of hollow-fibre haemodialysers
    Sinha, Ruhit
    Rocco, Michael V.
    Daeihagh, Pirouz
    Staples, Anne E.
    NATURE REVIEWS NEPHROLOGY, 2024, 20 (05) : 269 - 270
  • [46] Kinetic and enzymatic adsorption model in a recirculation hollow-fibre bioreactor
    E. Jurado
    F. Camacho
    G. Luzón
    J. M. Vicaria
    Bioprocess and Biosystems Engineering, 2005, 28 : 27 - 36
  • [47] A hollow-fibre column system to effectively prepare washed platelets
    Tanaka, S.
    Hayashi, T.
    Sugaya, S.
    Osabe, M.
    Ueno, Y.
    Tani, Y.
    Hirayama, F.
    VOX SANGUINIS, 2015, 109 (03) : 239 - 247
  • [48] Kinetic and enzymatic adsorption model in a recirculation hollow-fibre bioreactor
    Jurado, E
    Camacho, F
    Luzón, G
    Vicaria, JM
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2005, 28 (01) : 27 - 36
  • [49] Improved protein refolding using hollow-fibre membrane dialysis
    West, SM
    Chaudhuri, JB
    Howell, JA
    BIOTECHNOLOGY AND BIOENGINEERING, 1998, 57 (05) : 590 - 599
  • [50] Preparation and characterisation of Cibacron Blue F3G-A poly(ethylene) hollow-fibre affinity membranes
    Wolman, FJ
    Grasselli, M
    Smolko, EE
    Cascone, O
    BIOTECHNOLOGY LETTERS, 2000, 22 (17) : 1407 - 1411