Effects of two fretting damage modes on the dental implant-abutment interface and the generation of metal wear debris: An in vitro study

被引:14
|
作者
Gao, Jing [1 ]
Min, Jie [1 ]
Chen, Xin [2 ]
Yu, Ping [1 ]
Tan, Xin [1 ]
Zhang, Qianqian [2 ]
Yu, Haiyang [1 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, State Key Lab Oral Dis, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Natl Clin Res Ctr Oral Dis,Dept Dent Technol, Chengdu 610041, Peoples R China
关键词
central screw; chewing cycle loading; fatigue cycle loading; fretting damage; implant– abutment interface; wear debris; PERI-IMPLANTITIS; CONNECTIONS; FATIGUE; FORCES; BONE;
D O I
10.1111/ffe.13399
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Fretting damage at the dental implant-abutment interface (IAI) is a critical factor of dental implant failure, and it has been investigated using fatigue cycle (FC) loading tests. For the first time, we applied chewing cycle (CC) loading onto the IAI to simulate masticatory movements. It was found that more serious furrow wear was induced by the sliding forces present under CC loading. Furthermore, four types of metal wear debris and a markedly higher torque loss rate were observed after undergoing both cyclic loadings. Such debris can aggravate the resulting fretting damage, and an increased amount of large-grain wear debris was generated under CC loading. Therefore, CC loading can be an effective approach for exploring the fretting damage at the IAI to improve implant-supported prostheses.
引用
收藏
页码:847 / 858
页数:12
相关论文
共 30 条
  • [21] Removal capability, implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws: an in vitro study
    Bufala Perez, Maria
    Zubizarreta-Macho, Alvaro
    Borrajo Sanchez, Javier
    Hernandez Rodriguez, Jorge
    Alonso Perez-Barquero, Jorge
    Riad Deglow, Elena
    Hernandez Montero, Sofia
    BMC ORAL HEALTH, 2022, 22 (01)
  • [22] The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
    Amjadi, Mehrak
    Khajavi, Azadeh
    Youssefi, Navid
    Barjini, Negar
    Kazemi, Zahra
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2021, 21 (04) : 420 - 424
  • [23] The Effect of Dynamic Loading on Bacterial Colonization of the Dental Implant Fixture-Abutment Interface: An In Vitro Study
    Koutouzis, Theofilos
    Mesia, Ruben
    Calderon, Nadia
    Wong, Fong
    Wallet, Shannon
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) : 432 - 437
  • [24] Two Gingival Cell Lines Response to Different Dental Implant Abutment Materials: An In Vitro Study
    Osman, Muataz A.
    Kushnerev, Evgeny
    Alamoush, Rasha A.
    Seymour, Kevin G.
    Yates, Julian M.
    DENTISTRY JOURNAL, 2022, 10 (10)
  • [25] BACTERIAL COLONIZATION OF THE IMPLANT-ABUTMENT INTERFACE OF CONICAL CONNECTION WITH AN INTERNAL OCTAGON: AN IN VITRO STUDY USING REAL-TIME PCR
    Baj, A.
    Beltramini, G. A.
    Bolzoni, A.
    Cura, F.
    Palmieri, A.
    Scarano, A.
    Ottria, L.
    Gianni, A. B.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (02): : 163 - 168
  • [26] Wear particle release at the interface of dental implant components: Effects of different material combinations. An in vitro study
    Olander, Julia
    Ruud, Amund
    Wennerberg, Ann
    Stenport, Victoria Franke
    DENTAL MATERIALS, 2022, 38 (03) : 508 - 516
  • [27] Comparative evaluation of the wear resistance of two different implant abutment materials after cyclic loading - An in vitro study
    Ragupathi, Maniamuthu
    Mahadevan, Vallabh
    Azhagarasan, N. S.
    Ramakrishnan, Hariharan
    Jayakrishnakumar, S.
    CONTEMPORARY CLINICAL DENTISTRY, 2020, 11 (03) : 229 - 236
  • [28] The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study
    Gianfreda, Francesco
    Bollero, Patrizio
    Muzzi, Maurizio
    Di Giulio, Andrea
    Nicolai, Eleonora
    Canullo, Luigi
    DENTISTRY JOURNAL, 2022, 10 (03)
  • [29] Analysis of the Bacterial Seal at the Implant-Abutment Interface in External-Hexagon and Morse Taper-Connection Implants: An In Vitro Study Using a New Methodology
    Jaworski, Mario Eduardo
    Moreira Melo, Ana Claudia
    Telles Picheth, Cyntia Maria
    de Mattias Sartori, Divete Aparecida
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (05) : 1091 - 1095
  • [30] Effects of the conventional, soft start, and pulse delay modes produced by light- emitting diode device on metal brackets bond strength and enamel damage: An in vitro comparative study
    Najjar, Yasser Munther
    Burhan, Ahmad S.
    Hajeer, Mohammad Y.
    Nawaya, Fehmieh R.
    Alam, Mohammad Khursheed
    INTERNATIONAL ORTHODONTICS, 2023, 21 (03)