Threshold aerogel Cherenkov counters of the KEDR detector

被引:5
|
作者
Barnyakov, A. Yu. [1 ,3 ]
Barnyakov, M. Yu. [1 ,3 ]
Bobrovnikov, V. S. [1 ]
Buzykaev, A. R. [1 ,3 ]
Gulevich, V. V. [1 ]
Danilyuk, A. F. [2 ,3 ]
Katcin, A. A. [1 ,4 ]
Kononov, S. A. [1 ,3 ]
Kravchenko, E. A. [1 ,3 ]
Kuyanov, I. A. [1 ]
Onuchin, A. P. [1 ,3 ,4 ]
Ovtin, I. V. [1 ,4 ]
Rodyakin, V. A. [1 ]
机构
[1] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
[2] Boreskov Inst Catalysis, Novosibirsk 630090, Russia
[3] Novosibirsk State Univ, Novosibirsk 630090, Russia
[4] Novosibirsk State Tech Univ, Novosibirsk 630092, Russia
来源
关键词
Particle identification methods; Cherenkov detectors; MICROCHANNEL PLATE PHOTOTUBES; WAVELENGTH SHIFTERS;
D O I
10.1088/1748-0221/9/09/C09005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Particle identification system based on aerogel threshold Cherenkov counters ASHIPH (Aerogel SHifter PHotomultiplier) was installed in the KEDR detector in 2013. The system consists of 160 counters arranged in two layers and contains 1000 liters of aerogel with refractive index of 1.05 and 160 MCP PMTs with multialkali photocathode. The efficiency of relativistic particles detection was measured. Long-term stability of ASHIPH counters was studied. The main reasons of efficiency degradation are presented.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] THE AEROGEL CHERENKOV COUNTERS WITH WAVELENGTH SHIFTERS AND PHOTOTUBES
    ONUCHIN, A
    SHAMOV, A
    SKOVPEN, Y
    VOROBIOV, A
    DANILYUK, A
    GORODETSKAYA, T
    KUZNETSOV, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 517 - 520
  • [22] AEROGEL CHERENKOV COUNTERS - CONSTRUCTION PRINCIPLES AND APPLICATIONS
    CARLSON, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 248 (01): : 110 - 117
  • [23] Aerogel Cherenkov counters for high momentum proton identification
    Cuautle, E
    Di Bari, D
    Gorlychev, VG
    Karavicheva, TL
    Kurepin, AB
    Martínez, MI
    Nappi, E
    Paic, G
    Razin, VI
    Reshetin, AI
    Shileev, KA
    Ternavskij, AY
    Volpe, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 553 (1-2): : 25 - 29
  • [24] Recent results on aerogel development for use in Cherenkov counters
    Danilyuk, AF
    Kirillov, VL
    Savelieva, MD
    Bobrovnikov, VS
    Buzykaev, AR
    Kravchenko, EA
    Lavrov, AV
    Onuchin, AP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 494 (1-3): : 491 - 494
  • [25] Development of aerogel Cherenkov counters with wavelength shifters and phototubes
    Barnykov, MY
    Buzykaev, AR
    Danilyuk, AF
    Ganzhur, SF
    Goldberg, II
    Kolachev, GM
    Kononov, SA
    Kravchenko, EA
    Mikerov, VI
    Muraviova, TM
    Minakov, GD
    Onuchin, AP
    Sidorov, AV
    Tayursky, VA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3): : 584 - 589
  • [26] Development of aerogel Cherenkov counters with wavelength shifters and phototubes
    Barnykov, M.Yu.
    Buzykaev, A.R.
    Danilyuk, A.F.
    Ganzhur, S.F.
    Goldberg, I.I.
    Kolachev, G.M.
    Kononov, S.A.
    Kravchenko, E.A.
    Mikerov, V.I.
    Muraviova, T.M.
    Minakov, G.D.
    Onuchin, A.P.
    Sidorov, A.V.
    Tayursky, V.A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 419 (2-3): : 584 - 589
  • [27] Performance and design characteristics for the Hall A aerogel Cherenkov counters
    Lolos, GJ
    Huber, GM
    Alexa, LC
    Farzanpay, F
    Iurescu, M
    Papandreou, Z
    Weinerman, A
    Leone, A
    Perrino, R
    Garibaldi, F
    Jodice, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 385 (03): : 403 - 411
  • [28] Aerogel Cherenkov counter for the BELLE detector
    Iijima, T
    Adachi, I
    Enomoto, R
    Suda, R
    Sumiyoshi, T
    Leonidopoulos, C
    Marlow, DR
    Prebys, E
    Kawai, H
    Kurihara, E
    Nanao, M
    Suzuki, K
    Unno, Y
    Ogawa, S
    Murakami, A
    Khan, MHR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 321 - 325
  • [29] A concentrating light guide for threshold Cherenkov counters
    Gavrishchuk, O.P.
    Onuchin, V.A.
    Semenov, V.K.
    Suzdalev, V.I.
    Pribory i Tekhnika Eksperimenta, 1993, (02): : 217 - 222
  • [30] The aerogel threshold Cherenkov detector for the high momentum spectrometer in Hall C at Jefferson Lab
    Asaturyan, R
    Ent, R
    Fenker, H
    Gaskell, D
    Huber, GM
    Jones, M
    Mack, D
    Mkrtchyan, H
    Metzger, B
    Novikoff, N
    Tadevosyan, V
    Vulcan, W
    Wood, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (03): : 364 - 374