Parker Flex-It intubation stylet versus a 90-degree curved stylet during intubation with the McGrath videolaryngoscope performed by novices: a manikin study with 5 airway scenarios
被引:2
|
作者:
Reus, Erik
论文数: 0引用数: 0
h-index: 0
机构:
Univ Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, GermanyUniv Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, Germany
Reus, Erik
[1
]
Grundmann, Ulrich
论文数: 0引用数: 0
h-index: 0
机构:
Univ Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, GermanyUniv Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, Germany
Grundmann, Ulrich
[1
]
Liening, Katrin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, GermanyUniv Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, Germany
Liening, Katrin
[1
]
Wrobel, Marc
论文数: 0引用数: 0
h-index: 0
机构:
Univ Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, GermanyUniv Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, Germany
Wrobel, Marc
[1
]
机构:
[1] Univ Saarland, Dept Anesthesiol Intens Care Med & Pain Therapy, D-66421 Homburg, Germany
Study Objective: To compare the Parker Flex-It intubation stylet with a 90-degree curved stylet using the McGrath videolaryngoscope in 5 airway scenarios (from easy to difficult) in a manikin. Design: Prospective, randomized study. Setting: Academic hospital. Subjects: 20 staff anesthesiologists with no previous experience in videolaryngoscopy. Measurements: Subjects performed a total of 200 intubations with the McGrath Series 5 videolaiyngoscope and completed a questionnaire afterwards. Results: Overall success rate was significantly higher with the Parker Flex-It intubation stylet (96 successful intubations with the Parker Flex-It vs 79 intubations in the 90 degrees curved stylet group; P<0.05). Intubation time was not significantly different. Subjects rated the Parker Flex-It intubation stylet as the better device for intubation with the McGrath videolaryngoscope in routine or emergency situations. Conclusion: Intubation of the manikin with the McGrath videolaryngoscope had more success with the Parker Flex-It intubation stylet than a 90 degrees curved stylet. (C) 2013 Elsevier Inc. All rights reserved.
机构:
Saitama Med Univ, Int Med Ctr, Dept Anesthesiol, 1397-1 Yamane, Hidaka City, Saitama 3501298, JapanSaitama Med Univ, Int Med Ctr, Dept Anesthesiol, 1397-1 Yamane, Hidaka City, Saitama 3501298, Japan
Ueshima, Hironobu
Kitamura, Akira
论文数: 0引用数: 0
h-index: 0
机构:
Saitama Med Univ, Int Med Ctr, Dept Anesthesiol, 1397-1 Yamane, Hidaka City, Saitama 3501298, JapanSaitama Med Univ, Int Med Ctr, Dept Anesthesiol, 1397-1 Yamane, Hidaka City, Saitama 3501298, Japan
机构:
Tuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R ChinaTuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R China
Tsui, K. L.
Hung, C. Y.
论文数: 0引用数: 0
h-index: 0
机构:
Tuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R ChinaTuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R China
Hung, C. Y.
Kam, C. W.
论文数: 0引用数: 0
h-index: 0
机构:
Tuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R ChinaTuen Mun Hosp, Dept Accid & Emergency, Tuen Mun, Hong Kong, Peoples R China