Fetal lung volume and quantification of liver herniation by magnetic resonance imaging in isolated congenital diaphragmatic hernia

被引:120
|
作者
Ruano, R. [1 ,2 ]
Lazar, D. A. [1 ,3 ]
Cass, D. L. [1 ,3 ]
Zamora, I. J. [1 ,3 ]
Lee, T. C. [1 ,3 ]
Cassady, C. I. [1 ,4 ]
Mehollin-Ray, A. [1 ,4 ]
Welty, S. [1 ,5 ]
Fernandes, C. J. [1 ,5 ]
Haeri, S. [1 ,2 ]
Belfort, M. A. [1 ,2 ]
Olutoye, O. O. [1 ,3 ]
机构
[1] Texas Childrens Hosp, Texas Childrens Fetal Ctr, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Obstet & Gynecol, Houston, TX 77030 USA
[3] Baylor Coll Med, Michael E DeBakey Dept Surg, Houston, TX 77030 USA
[4] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[5] Baylor Coll Med, Dept Pediat, Sect Neonatol, Houston, TX 77030 USA
关键词
congenital diaphragmatic hernia; diaphragm hernia outcomes; fetal lung volumes; fetal ultrasound; liver herniation; lung-to-head ratio; magnetic resonance imaging; prenatal diagnosis; prenatal predictors; OPERATING CHARACTERISTIC CURVES; ENDOSCOPIC TRACHEAL OCCLUSION; 3-DIMENSIONAL ULTRASONOGRAPHY; PULMONARY HYPOPLASIA; PRENATAL PREDICTION; SURVIVAL; FETUSES; RATIO; MANAGEMENT; POSITION;
D O I
10.1002/uog.13223
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To determine associations between fetal lung and liver herniation volumes measured by magnetic resonance imaging (MRI) and mortality/need for extracorporeal membrane oxygenation (ECMO) in cases of isolated congenital diaphragmatic hernia (CDH). A secondary objective was to compare prenatal MRI parameters with two-dimensional ultrasound lung measurements. Methods A retrospective review of medical records of all fetuses with isolated CDH evaluated between January 2004 and July 2012 was performed. The following MRI parameters were measured at 20-32 weeks: observed/expected total fetal lung volume (o/e-TLV), predicted pulmonary volume (PPV), percentage of liver herniated into the fetal thorax (%LH) and the liver/thoracic volume ratio (LiTR). These were compared with the ultrasound-determined lung-to-head ratio (LHR) and the observed/expected LHR (o/e-LHR) in the same cohort. The predictive value of MRI and ultrasound parameters for mortality and the need for ECMO was evaluated by univariate, multivariate and factor analysis and by receiver-operating characteristics curves. Results Eighty fetuses with isolated CDH were evaluated. Overall mortality was 18/80 (22.5%). Two newborns died a few hours after birth. ECMO was performed in 29/78 (37.2%) newborns, with a survival rate of 48.3% (14/29). The side of the diaphragmatic defect was not associated with mortality (P = 0.99) or the need for ECMO(P = 0.48). Good correlation was observed among o/e-TLV, PPV, LHR and o/e-LHR as well as between %LH and LiTR (r = 0.89; P < 0.01); however, fetal lung measurements and measures of liver herniation were not correlated (all P > 0.05). All parameters were statistically associated with mortality or the need for ECMO. The best combination of measurements to predict mortality was o/e-TLV and %LH, with 83% accuracy. Conclusion Mortality and the need for ECMO in neonates with isolated CDH can be best predicted using a combination of MRI o/e-TLV and %LH. Copyright (C) 2013 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [21] Fetal brain morphometry on prenatal magnetic resonance imaging in congenital diaphragmatic hernia
    Radhakrishnan, Rupa
    Merhar, Stephanie L.
    Burns, Patricia
    Zhang, Bin
    Lim, Foong-Yen
    Kline-Fath, Beth M.
    PEDIATRIC RADIOLOGY, 2019, 49 (02) : 217 - 223
  • [22] Comparison of the lung-to-head ratio and fetal lung volume measurement by magnetic resonance imaging (MRI) in fetuses with congenital diaphragmatic hernia (CDH)
    Jani, Jacques
    Cannie, Mieke
    De Keyzer, Frederik
    Van Schoubroek, Dominique
    Dymarkowski, Steven
    Deprest, Jan
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (06) : S60 - S60
  • [23] Isolated impact of liver herniation on outcome in fetuses with congenital diaphragmatic hernia - A matched-pair analysis based on fetal MRI relative lung volume
    Weis, M.
    Hoffmann, S.
    Henzler, C.
    Weiss, C.
    Schoenberg, S. O.
    Schaffelder, R.
    Schaible, T.
    Neff, K. W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 148 - 152
  • [24] Evaluation of Neonatal Lung Volume Growth by Pulmonary Magnetic Resonance Imaging in Patients with Congenital Diaphragmatic Hernia
    Schopper, Melissa A.
    Walkup, Laura L.
    Tkach, Jean A.
    Higano, Nara S.
    Lim, Foong Yen
    Haberman, Beth
    Woods, Jason C.
    Kingma, Paul S.
    JOURNAL OF PEDIATRICS, 2017, 188 : 96 - +
  • [25] Magnetic resonance imaging as a predictor of outcome in fetuses with isolated congenital diaphragmatic hernia
    Worley, Kevin C.
    Dashe, Jodi S.
    Oliver, Qian
    Megison, Steven
    Barber, Robert
    McIntire, Donald D.
    Twickler, Diane M.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (06) : S78 - S78
  • [26] Quantification of liver herniation in fetuses with isolated congenital diaphragmatic hernia using two-dimensional ultrasonography
    Britto, I. S. Werneck
    Olutoye, O. O.
    Cass, D. L.
    Zamora, I. J.
    Lee, T. C.
    Cassady, C. I.
    Mehollin-Ray, A.
    Welty, S.
    Fernandes, C.
    Belfort, M. A.
    Lee, W.
    Ruano, R.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (02) : 150 - 154
  • [27] The value of using multiple magnetic resonance imaging variables in prediction of fetal survival in isolated congenital diaphragmatic hernia
    Rahaim, N.
    Whitby, E.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 66 - 66
  • [28] The Necessity of Magnetic Resonance Imaging in Congenital Diaphragmatic Hernia
    Nestianu, Erick George
    Bradeanu, Cristina Guramba
    Alexandru, Dragos Ovidiu
    Vladareanu, Radu
    DIAGNOSTICS, 2022, 12 (07)
  • [29] The correlation between lung volume and liver herniation measurements by fetal MRI in isolated congenital diaphragmatic hernia: a systematic review and meta-analysis of observational studies
    Mayer, Steffi
    Klaritsch, Philipp
    Petersen, Scott
    Done, Elisa
    Sandaite, Inga
    Till, Holger
    Claus, Filip
    Deprest, Jan A.
    PRENATAL DIAGNOSIS, 2011, 31 (11) : 1086 - 1096
  • [30] The relationship between three signs of fetal magnetic resonance imaging and severity of congenital diaphragmatic hernia
    T Hattori
    M Hayakawa
    M Ito
    Y Sato
    K Tamakoshi
    Y Kanamori
    H Okuyama
    N Inamura
    S Takahashi
    Y Fujino
    T Taguchi
    N Usui
    Journal of Perinatology, 2017, 37 : 265 - 269