Towards Clinical Application of a Laplace Operator-Based Region of Interest Reconstruction Algorithm in C-Arm CT

被引:10
|
作者
Xia, Yan [1 ,2 ]
Hofmann, Hannes [1 ]
Dennerlein, Frank [3 ]
Mueller, Kerstin [1 ,2 ]
Schwemmer, Chris [1 ,2 ]
Bauer, Sebastian [4 ]
Chintalapani, Gouthami [5 ]
Chinnadurai, Ponraj [5 ]
Hornegger, Joachim [1 ,2 ]
Maier, Andreas [1 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91058 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91052 Erlangen, Germany
[3] Siemens AG, Healthcare Sect, D-91052 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
[5] Siemens Med Solut USA Inc, Hoffman Estates, IL 60195 USA
关键词
C-arm CT; dose reduction; image reconstruction; region of interest; truncation; truncation artifact; DIGITAL-SUBTRACTION-ANGIOGRAPHY; VOLUME-OF-INTEREST; FLAT-DETECTOR CT; IMAGE-RECONSTRUCTION; HILBERT TRANSFORM; 2D; QUALITY;
D O I
10.1109/TMI.2013.2291622
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It is known that a reduction of the field-of-view in 3-D X-ray imaging is proportional to a reduction in radiation dose. The resulting truncation, however, is incompatible with conventional reconstruction algorithms. Recently, a novel method for region of interest reconstruction that uses neither prior knowledge nor extrapolation has been published, named approximated truncation robust algorithm for computed tomography (ATRACT). It is based on a decomposition of the standard ramp filter into a 2-D Laplace filtering and a 2-D Radon-based residual filtering step. In this paper, we present two variants of the original ATRACT. One is based on expressing the residual filter as an efficient 2-D convolution with an analytically derived kernel. The second variant is to apply ATRACT in 1-D to further reduce computational complexity. The proposed algorithms were evaluated by using a reconstruction benchmark, as well as two clinical data sets. The results are encouraging since the proposed algorithms achieve a speed-up factor of up to 245 compared to the 2-D Radon-based ATRACT. Reconstructions of high accuracy are obtained, e. g., even real-data reconstruction in the presence of severe truncation achieve a relative root mean square error of as little as 0.92% with respect to nontruncated data.
引用
收藏
页码:593 / 606
页数:14
相关论文
共 31 条
  • [21] Impact of Image Reconstruction Algorithm Using Novel C-Arm Linac CBCT Solution on the Quality of a Deformed Simulation CT for Dose Calculation in Adaptive Radiotherapy
    Price, A. T.
    Arsenault, T. H.
    Gregg, K. W.
    Guevara, B.
    Rezaei, A.
    Jia, A.
    Spratt, D. E.
    Henke, L.
    Kashani, R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7947 - 7947
  • [22] Cardiac C-arm CT:: 4D non-model based heart motion estimation and its application
    Pruemmer, M.
    Fahrig, R.
    Wigstroem, L.
    Boese, J.
    Lauritsch, G.
    Strobel, N.
    Hornegger, J.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [23] Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography
    Langet, Helene
    Riddell, Cyril
    Reshef, Aymeric
    Trousset, Yves
    Tenenhaus, Arthur
    Lahalle, Elisabeth
    Fleury, Gilles
    Paragios, Nikos
    MEDICAL PHYSICS, 2015, 42 (09) : 5222 - 5237
  • [24] Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization
    Estler, Arne
    Bongers, Malte
    Thomas, Christoph
    Hefferman, Gerald
    Hofmann, Johannes
    Hoffmann, Ruediger
    Nikolaou, Konstantin
    Grosse, Ulrich
    Groezinger, Gerd
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (10) : 1449 - 1458
  • [25] Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization
    Arne Estler
    Malte Bongers
    Christoph Thomas
    Gerald Hefferman
    Johannes Hofmann
    Rüdiger Hoffmann
    Konstantin Nikolaou
    Ulrich Grosse
    Gerd Grözinger
    CardioVascular and Interventional Radiology, 2019, 42 : 1449 - 1458
  • [26] Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma
    Wang, Zhi-Jun
    Wang, Mao-Qiang
    Duan, Feng
    Song, Peng
    Liu, Feng-Yong
    Wang, Yan
    Yan, Jie-Yu
    Li, Kai
    Yuan, Kai
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2013, 14 (03) : 1649 - 1654
  • [27] Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
    Zhuang, Tingliang
    Zambelli, Joseph
    Nett, Brian
    Leng, Shuai
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [28] Architecture of a High-Performance Surgical Guidance System Based on C-Arm Cone-Beam CT: Software Platform for Technical Integration and Clinical Translation
    Uneri, Ali
    Schafer, Sebastian
    Mirota, Daniel
    Nithiananthan, Sajendra
    Otake, Yoshito
    Reaungamornrat, Sureerat
    Yoo, Jongheun
    Stayman, J. Webster
    Reh, Douglas
    Gallia, Gary L.
    Khanna, A. Jay
    Hager, Gregory
    Taylor, Russell H.
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [29] JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention
    Wang, A.
    Stayman, J.
    Otake, Y.
    Gallia, G.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 526 - 526
  • [30] Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions
    Jiao, De-Chao
    Li, Teng-Fei
    Han, Xin-Wei
    Wu, Gang
    Ma, Ji
    Fu, Ming-Ti
    Sun, Qi
    Beilner, Janina
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (06) : 470 - 474