Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography-part 2: image reconstruction

被引:10
|
作者
Correia, Teresa [1 ]
Koch, Maximilian [2 ,3 ]
Ale, Angelique [4 ]
Ntziachristos, Vasilis [2 ,3 ]
Arridge, Simon [1 ]
机构
[1] UCL, Dept Comp Sci, Ctr Med Imaging Comp, Gower St, London WC1 E6BT, England
[2] Tech Univ Munich, Neuherberg, Germany
[3] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, Neuherberg, Germany
[4] Univ London Imperial Coll Sci Technol & Med, Dept Life Sci, Ctr Integrat Syst Biol & Bioinformat, London SW7 2AZ, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
fluorescence diffuse optical tomography; image reconstruction; anisotropic diffusion; nonlocal means; structural information; multimodal imaging; regularisation; TOTAL VARIATION REGULARIZATION; EFFICIENT NONLOCAL-MEANS; RAY COMPUTED-TOMOGRAPHY; MOLECULAR TOMOGRAPHY; INFORMATION; SYSTEM; ALGORITHMS; PRIORS; CT;
D O I
10.1088/0031-9155/61/4/1452
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. We propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. Furthermore, structural information can be incorporated into the image reconstruction with PAD-WT to improve image quality and resolution. In this case, the weights used to average voxels in the image are calculated using the structural image, instead of the fluorescence image. The regularisation strength depends on both structural and fluorescence images, which guarantees that the method can preserve fluorescence information even when it is not structurally visible in the anatomical images. In part 1, we tested the method using a denoising problem. Here, we use simulated and in vivo mouse fDOT data to assess the algorithm performance. Our results show that the proposed PAD-WT method provides high quality and noise free images, superior to those obtained using AD.
引用
收藏
页码:1452 / 1475
页数:24
相关论文
共 50 条
  • [1] Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography-part 1: technical principles
    Correia, Teresa
    Arridge, Simon
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1439 - 1451
  • [2] Dictionary learning and patch-based regularization image reconstruction for positron emission tomography
    Hu, Z.
    Zhang, W.
    Gao, J.
    Yang, Y.
    Liang, D.
    Liu, X.
    Zheng, H.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 595 - 595
  • [3] Image reconstruction for emission tomography using intensity normalised patch-based regularisation
    Ren, Xue
    Lee, Soo-Jin
    IET IMAGE PROCESSING, 2019, 13 (05) : 794 - 803
  • [4] Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning
    Zhang, Wanhong
    Gao, Juan
    Yang, Yongfeng
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Hu, Zhanli
    MEDICAL PHYSICS, 2019, 46 (11) : 5014 - 5026
  • [5] Research on Optimization Scheme for Blocking Artifacts after Patch-Based Medical Image Reconstruction
    Xu, Yan
    Hu, Shunbo
    Du, Yuyue
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [6] Deep Learning Based Image Reconstruction for Diffuse Optical Tomography
    Ben Yedder, Hanene
    BenTaieb, Aicha
    Shokoufi, Majid
    Zahiremami, Amir
    Golnaraghi, Farid
    Hamarneh, Ghassan
    MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION, MLMIR 2018, 2018, 11074 : 112 - 119
  • [7] Fluorescence Diffuse Optical Tomography Reconstruction Based on Group Sparse Regularization
    Li Xiaolin
    Fu Hongsun
    Song Bolin
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (02)
  • [8] Wavelet-based data and solution compression for efficient image reconstruction in fluorescence diffuse optical tomography
    Correia, Teresa
    Rudge, Timothy
    Koch, Maximilian
    Ntziachristos, Vasilis
    Arridge, Simon
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [9] An Adaptive Patch-Based Reconstruction Scheme for View Synthesis by Disparity Estimation Using Optical Flow
    Kaviani, Hoda Rezaee
    Shirani, Shahram
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2018, 28 (07) : 1540 - 1552
  • [10] Contrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction
    Davis, SC
    Pogue, BW
    Dehghani, H
    Paulsen, KD
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (05)