Contrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction

被引:46
|
作者
Davis, SC [1 ]
Pogue, BW [1 ]
Dehghani, H [1 ]
Paulsen, KD [1 ]
机构
[1] Thayer Sch Engn, Dartmouth Coll, Hanover, NH 03755 USA
关键词
D O I
10.1117/1.2114727
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to approximate a lowest acceptable noise level in the image, as a surrogate measure for human detection of objects. For objects 0.5 cm inside the edge of a simulated tissue region, the smallest diameter that met this criteria was approximately 1.7 mm, regardless of contrast level, and test field diameter had little impact on this limit. Object depth had substantial impact on object CNR, leading to a limit of 4 mm for objects near the center of a 51-mm test field and 8.5 mm for an 86-mm test field. Similarly, large objects near the edge of both test fields required a minimum contrast of 50% to achieve acceptable image CNR. The minimum contrast for large, centered objects ranged between 50% and 100%. Contrast-detail analysis using human detection of lower contrast limits provides fundamentally important information about the performance of reconstruction algorithms, and can be used to compare imaging performance of different systems. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Characterizing atherosclerotic plaque with Computed Tomography: a Contrast-Detail study
    Kasraie, Nima
    Clarke, Geoffrey David
    MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318
  • [2] Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography
    Pogue, BW
    Willscher, C
    McBride, TO
    Österberg, UL
    Paulsen, KD
    MEDICAL PHYSICS, 2000, 27 (12) : 2693 - 2700
  • [3] Automated Analysis of Contrast-Detail Phantom Image in Mammography
    Tsuru, H.
    Yasuda, K.
    Moriyama, M.
    Ohki, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Contrast-detail analysis of image degradation due to lossy compression
    Department of Radiology, University of Kansas Medical Center, 3901 Rainbow Boulevard, Kansas City, KS 66160-7234, United States
    MED. PHYS., 6 (715-721):
  • [5] ANALYSIS OF VARIATIONS IN CONTRAST-DETAIL EXPERIMENTS
    COHEN, G
    MCDANIEL, DL
    WAGNER, LK
    MEDICAL PHYSICS, 1984, 11 (04) : 469 - 473
  • [6] CONTRAST-DETAIL ANALYSIS OF IMAGE DEGRADATION DUE TO LOSSY COMPRESSION
    COOK, LT
    INSANA, MF
    MCFADDEN, MA
    HALL, TJ
    COX, GG
    MEDICAL PHYSICS, 1995, 22 (06) : 715 - 721
  • [7] Contrast-detail analysis of the effect of image compression on computed tomographic images
    Cook, LT
    Cox, GG
    Insana, MF
    McFadden, MA
    Hall, TJ
    Gaborski, RS
    Lure, FYM
    IMAGE PERCEPTION - MEDICAL IMAGING 1996, 1996, 2712 : 128 - 137
  • [8] Determination of contrast-detail curves of mammography systems by automated image analysis
    Karssemeijer, N
    Thijssen, MAO
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 155 - 160
  • [9] The application of Markov theory to contrast-detail analysis
    Imai, K
    Ikeda, M
    Niimi, T
    ACADEMIC RADIOLOGY, 2006, 13 (02) : 152 - 158
  • [10] FREQUENCY INDEPENDENT ULTRASOUND CONTRAST-DETAIL ANALYSIS
    SMITH, SW
    LOPEZ, H
    BODINE, WJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03): : 467 - 477