Contrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction

被引:46
|
作者
Davis, SC [1 ]
Pogue, BW [1 ]
Dehghani, H [1 ]
Paulsen, KD [1 ]
机构
[1] Thayer Sch Engn, Dartmouth Coll, Hanover, NH 03755 USA
关键词
D O I
10.1117/1.2114727
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to approximate a lowest acceptable noise level in the image, as a surrogate measure for human detection of objects. For objects 0.5 cm inside the edge of a simulated tissue region, the smallest diameter that met this criteria was approximately 1.7 mm, regardless of contrast level, and test field diameter had little impact on this limit. Object depth had substantial impact on object CNR, leading to a limit of 4 mm for objects near the center of a 51-mm test field and 8.5 mm for an 86-mm test field. Similarly, large objects near the edge of both test fields required a minimum contrast of 50% to achieve acceptable image CNR. The minimum contrast for large, centered objects ranged between 50% and 100%. Contrast-detail analysis using human detection of lower contrast limits provides fundamentally important information about the performance of reconstruction algorithms, and can be used to compare imaging performance of different systems. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Effective optode configuration for the image reconstruction in diffuse optical tomography
    Uchida K.
    Okawa S.
    Matsuhashi S.
    Hoshi Y.
    Yamada Y.
    Medical Laser Application, 2010, 25 (03): : 154 - 160
  • [42] Efficient reliable image reconstruction schemes for diffuse optical tomography
    Egger, Herbert
    Schlottbom, Matthias
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2011, 19 (02) : 155 - 180
  • [43] Wavelet-based data and solution compression for efficient image reconstruction in fluorescence diffuse optical tomography
    Correia, Teresa
    Rudge, Timothy
    Koch, Maximilian
    Ntziachristos, Vasilis
    Arridge, Simon
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [44] Image analysis methods for diffuse optical tomography
    Pogue, Brian W.
    Davis, Scott C.
    Song, Xiaomei
    Brooksby, Ben A.
    Dehghani, Hamid
    Paulsen, Keith D.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (03)
  • [45] Image analysis methods for diffuse optical tomography
    Dartmouth College, Thayer School of Engineering, 8000 Cummings Hall, Hanover, NH 03755, United States
    J Biomed Opt, 2006, 3
  • [46] AN ALTERNATIVE APPROACH TO CONTRAST-DETAIL TESTING OF X-RAY IMAGE INTENSIFIER SYSTEMS
    KOTRE, CJ
    MARSHALL, NW
    FAULKNER, K
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776): : 686 - 690
  • [47] A Perceptual Evaluation of JPEG 2000 Image Compression for Digital Mammography: Contrast-Detail Characteristics
    Sankararaman Suryanarayanan
    Andrew Karellas
    Srinivasan Vedantham
    Sandra M. Waldrop
    Carl J. D’Orsi
    Journal of Digital Imaging, 2004, 17 : 64 - 70
  • [48] 3-D Contrast-Detail Analysis for Dedicated Emission Mammotomography
    Cutler, Spencer J.
    Perez, Kristy L.
    Tornai, Martin P.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2954 - 2958
  • [49] CONTRAST-DETAIL DETECTION POTENTIAL OF SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    LIM, CB
    GOTTSCHALK, SC
    MEDICAL PHYSICS, 1983, 10 (04) : 548 - 548
  • [50] 4-D Reconstruction for Dynamic Fluorescence Diffuse Optical Tomography
    Liu, Xin
    Zhang, Bin
    Luo, Jianwen
    Bai, Jing
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (11) : 2120 - 2132