Bin loads induced by eccentric filling and discharge of grain

被引:0
|
作者
Molenda, M
Horabik, J
Thompson, SA
Ross, IJ [1 ]
机构
[1] Univ Kentucky, Dept Agr & Biosyst Engn, Lexington, KY 40546 USA
[2] Polish Acad Sci, Inst Agrophys, PL-20236 Lublin, Poland
[3] Univ Georgia, Dept Biol & Agr Engn, Athens, GA 30602 USA
来源
TRANSACTIONS OF THE ASAE | 2002年 / 45卷 / 03期
关键词
grain bin loads; eccentric bin loading; grain loads;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Wall loads were measured in a corrugated-wall model grain bin 2.44 m in diameter and 7.3 m high filled with wheat to a HID ratio equal to 2.0. The model bin was filled either centrally or eccentrically through a chute located along a radial line, coinciding with one of the major axis of the bin, at eccentricity ratios of 0, 0.5, or 0.75. The eccentricity ratio (ER) is defined as the ratio of the distance from the center of the bin to either the filling location or the discharge gate divided by the radius of the bin. The model bin was unloaded either centrally or eccentrically through discharge gates located at ERs of 0, +/-0.5, or +/-0.7. For both an ER of 0.5 and 0.7, two different eccentric discharge gates were used, located on opposite (plus or minus) sides of the bin on a major axis that was parallel to the filling axis. For experiments involving centric filling followed by eccentric unloading, a maximum wall moment of 11.2 kN-m was measured. For experiments involving eccentric filling followed by eccentric unloading, the mutual location of the filling and discharge gates either magnified or reduced the variation in stress within the bin and the resulting moment carried by the walls. For experiments in which the location of both the filling and discharge gates were on the same side of bin, a maximum wall moment of 17.5 kN-m was measured. For tests in which the filling chute was located on the opposite side of the bin from the discharge gate, a maximum wall moment of 3.2 kN-m was measured.
引用
收藏
页码:781 / 785
页数:5
相关论文
共 50 条
  • [21] Loads caused by bottom unloading wall flumes in a model grain bin
    Thompson, SA
    Molenda, M
    Ross, IJ
    Bucklin, RA
    [J]. TRANSACTIONS OF THE ASAE, 1998, 41 (06): : 1807 - 1815
  • [22] Wall loads in a model grain bin during fill and unload cycles
    Horabik, J
    Molenda, M
    Ross, IJ
    [J]. TRANSACTIONS OF THE ASAE, 1999, 42 (03): : 771 - 775
  • [23] Dynamic load response in a model bin at the start of grain discharge
    Molenda, M
    Horabik, J
    Ross, IJ
    [J]. TRANSACTIONS OF THE ASAE, 1995, 38 (06): : 1869 - 1873
  • [24] DEM modelling of silo load asymmetry due to eccentric filling and discharge
    Kobylka, R.
    Molenda, M.
    [J]. POWDER TECHNOLOGY, 2013, 233 : 65 - 71
  • [25] Vertical floor pressures during filling of a full-scale grain bin
    Thompson, SA
    Galili, N
    Williams, RA
    [J]. TRANSACTIONS OF THE ASAE, 1996, 39 (03): : 1093 - 1100
  • [26] ON THEORY OF BIN LOADS
    JENIKE, AW
    JOHANSON, JR
    [J]. MECHANICAL ENGINEERING, 1969, 91 (01) : 43 - &
  • [27] ON THEORY OF BIN LOADS
    JENIKE, AW
    JOHANSON, JR
    [J]. JOURNAL OF ENGINEERING FOR INDUSTRY, 1969, 91 (02): : 339 - &
  • [28] MEASUREMENT OF THERMALLY INDUCED PRESSURES IN A MODEL GRAIN BIN
    MANBECK, HB
    MUZZELO, LM
    [J]. TRANSACTIONS OF THE ASAE, 1985, 28 (04): : 1253 - &
  • [29] WHEAT LOADS AND VERTICAL PRESSURE DISTRIBUTION IN A FULL-SCALE BIN .1. FILLING
    SCHWAB, CV
    ROSS, IJ
    WHITE, GM
    COLLIVER, DG
    [J]. TRANSACTIONS OF THE ASAE, 1994, 37 (05): : 1613 - 1619
  • [30] Vertical wall loads in a model grain bin with non-axial internal inserts
    Molenda, M
    Montross, MD
    Horabik, J
    Thompson, SA
    [J]. TRANSACTIONS OF THE ASAE, 2004, 47 (05): : 1681 - 1688