Evaluation of rubella IgM enzyme immunoassays

被引:42
|
作者
Tipples, GA [1 ]
Hamkar, R
Mohktari-Azad, T
Gray, M
Ball, J
Head, C
Ratnam, S
机构
[1] Hlth Canada, Natl Microbiol Lab, Winnipeg, MB, Canada
[2] Univ Tehran Med Sci, Tehran, Iran
[3] Newfoundland Publ Hlth Lab, St John, NF, Canada
关键词
rubella; serology; IgM;
D O I
10.1016/j.jcv.2003.11.006
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Rubella virus generally causes a mild fever, rash illness similar in clinical presentation to infections by other viruses including measles and parvovirus B19. Rubella infections in pregnant women in the first trimester carry a high risk of congenital rubella syndrome (CRS) which can result in severe congenital defects in the infants. The goal of rubella immunization programs is therefore to eliminate CRS. The primary test for the laboratory confirmation of rubella is IgM serology. It is therefore important to evaluate currently available commercial rubella IgM immunoassays to ensure high quality rubella diagnostic testing. Study design: In this study, we compared the performance of seven commercial rubella IgM enzyme immunoassays (EIA) (Meddens, Denka Seiken, Behring, Wampole, Captia, Sigma and Abbott Axsym) using well-defined panels of sera from rubella and non-rubella/rash-illness cases. Results: The Meddens, Denka Seiken, Behring and Wampole rubella IgM EIAs all performed similarly for sensitivity (range of 74.1-76.8%) and specificity (range of 93.9-96.1%). Relative to the other assays, the Axsym had a higher sensitivity (78.9%) but lower specificity (86.5%). The Captia assay had the lowest overall sensitivity (66.4%), while the Sigma assay had a lower specificity (85.6%) in relation to the other assays. Conclusions: In conclusion, the Meddens, Denka Seiken, Behring and Wampole rubella IgM EIAs are comparable in their overall performance with respect to sensitivity and specificity. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
  • [31] EVALUATION OF ENZYME IMMUNOSORBENT RUBELLA ASSAYS
    SKENDZEL, LP
    EDSON, DC
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1985, 109 (05) : 391 - 393
  • [32] THE USE OF MONOCLONAL AND POLYCLONAL ANTIBODIES IN THE IGM CAPTURE ENZYME-IMMUNOASSAY (MACEIA) FOR RUBELLA SPECIFIC IGM
    CHANTLER, S
    EVANS, C
    COOPER, L
    HEWITT, J
    IMMUNOLOGICAL COMMUNICATIONS, 1983, 12 (01): : 135 - 135
  • [33] Comparative study of different enzyme immunoassays for measurement of IgM and IgA rheumatoid factors
    Bas, S
    Perneger, TV
    Kunzle, E
    Vischer, TL
    ANNALS OF THE RHEUMATIC DISEASES, 2002, 61 (06) : 505 - 510
  • [34] AUTOMATED MICROPARTICLE ENZYME IMMUNOASSAYS FOR IGG AND IGM ANTIBODIES TO TOXOPLASMA-GONDII
    SAFFORD, JW
    ABBOTT, GG
    CRAINE, MC
    MACDONALD, RG
    JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (03) : 238 - 242
  • [35] EVALUATION OF ENZYME IMMUNOASSAYS FOR THE DETECTION OF HUMAN ROTAVIRUS
    YOLKEN, RH
    LEISTER, FJ
    JOURNAL OF INFECTIOUS DISEASES, 1981, 144 (04): : 379 - 379
  • [36] EVALUATION OF ENDPOINT TITRATION, SINGLE DILUTION AND CAPTURE ENZYME IMMUNOASSAYS FOR MEASUREMENT OF ANTIROTAVIRAL IGA AND IGM IN INFANTILE SECRETIONS AND SERUM
    COULSON, BS
    GRIMWOOD, K
    BISHOP, RF
    BARNES, GL
    JOURNAL OF VIROLOGICAL METHODS, 1989, 26 (01) : 53 - 65
  • [37] Evaluation of four commercial immunoglobulin G (IgG)- and IgM-specific enzyme immunoassays for diagnosis of Mycoplasma pneumoniae infections
    Petitjean, J
    Vabret, A
    Gouarin, S
    Freymuth, F
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (01) : 165 - 171
  • [38] Comparative evaluation of assays for IgM detection of rubella and measles infections
    Perez Olmeda, Mayte
    Balfagon, Pilar
    Camacho, Juan
    Dafouz, Desiree
    de la Fuente, Jesus
    Angeles Murillo, Maria
    Luis Munoz, Jose
    Fernandez Garcia, Aurora
    Carlos Sanz, Juan
    de Ory, Fernando
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2022, 40 (01): : 22 - 27
  • [39] Evaluation of Rubella IgG and IgM assays on the new Vidia® instrument
    Medici, M. C.
    Albonetti, V.
    Martinelli, M.
    Chezzi, C.
    Dettori, G.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S640 - S641
  • [40] Evaluation of four commercial immunoglobulin G (IgG)- and IgM-specific enzyme immunoassays for diagnosis of Mycoplasma pneumoniae infections
    Petitjean, J
    Vabret, A
    Gouarin, S
    Freymuth, F
    PATHOLOGIE BIOLOGIE, 2002, 50 (09): : 530 - 537