Flow injection chemiluminescence determination of hydrogen peroxide with in-situ electrogenerated Br2 as the oxidant

被引:0
|
作者
Zheng, XW [1 ]
Yang, M
Zhang, ZJ
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Liaoning Normal Univ, Dalian, Peoples R China
关键词
electrogenerated chemiluminescence; flow injection analysis; electrogenerated Br-2; hydrogen peroxide;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By designing a novel flow-through electrolytic cell, Br-2, an unstable and toxic reagent, can be produced in-situ on the near region of a platinum electrode surface by constant current oxidizing KBr in H2SO4 medium. At the same time, it was found that a strong CL signal was produced when the basic H2O2 solution was injected into the electrolytic cell. Based on this observation, a simple, rapid and selective ECL method for the determination of H2O2 was proposed. Factors affecting the determination of H2O2, including the chemical and flow-injection parameters as well as the design of flow-through electrolytic cell, were investigated, and the possible ECL reaction mechanism was also discussed. Under the optimum conditions, the ECL emission intensity was linear with H2O2 concentration in the range of 1.0x10(-6) - 4.0x10(-3) mol/L and with 3.5x10(-7) mol/L detection limit.
引用
收藏
页码:3013 / 3028
页数:16
相关论文
共 50 条
  • [41] Shipboard determination of hydrogen peroxide in the western Mediterranean sea using flow injection with chemiluminescence detection
    Price, D
    Fauzi, R
    Mantoura, C
    Worsfold, PJ
    ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) : 145 - 155
  • [42] Electrogenerated chemiluminescence from luminol-labelled microbeads triggered by in situ generation of hydrogen peroxide
    Fiorani, Andrea
    Santo, Claudio Ignazio
    Sakanoue, Kohei
    Calabria, Donato
    Mirasoli, Mara
    Paolucci, Francesco
    Valenti, Giovanni
    Einaga, Yasuaki
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (30) : 7277 - 7283
  • [43] In-situ production of hydrogen peroxide as oxidant for direct urea fuel cell
    Fan, Zheng
    Kwon, Yong-Hyok
    Yang, Xu
    Xu, Wei
    Wu, Zucheng
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 1858 - 1863
  • [44] The investigation of a new flow-injection analysis electrogenerated chemiluminescence method and the determination of S2-
    Zheng, XW
    Zhang, ZJ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (02): : 209 - 213
  • [45] Flow-injection Chemiluminescence Sensor for Hydrogen Peroxide with Immobilized Reagents
    Bao Xin LI
    Wei QIN
    Zhu Jun ZHANG (Department of Chemistry
    Chinese Chemical Letters, 1998, (05) : 471 - 472
  • [46] Flow-injection chemiluminescence sensor for hydrogen peroxide with immobilized reagents
    Li, BX
    Qin, W
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (05) : 471 - 472
  • [47] IN-SITU OXIDATIVE-DEGRADATION OF FORMALDEHYDE WITH HYDROGEN-PEROXIDE ELECTROGENERATED ON THE MODIFIED GRAPHITES
    DO, JS
    CHEN, CP
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1994, 24 (09) : 936 - 942
  • [48] FLOW-INJECTION DETERMINATION OF BENZIMIDAZOLE FUNGICIDES IN NATURAL WATERS WITH COPPER(II)-HYDROGEN PEROXIDE CHEMILUMINESCENCE
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL LETTERS, 2010, 43 (04) : 603 - 617
  • [49] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Martín, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 189 - 194
  • [50] DETERMINATION OF HYDROGEN-PEROXIDE IN SEA-WATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    PRICE, D
    WORSFOLD, PJ
    MANTOURA, RFC
    ANALYTICA CHIMICA ACTA, 1994, 298 (01) : 121 - 128