Determination of isoflavones in commercial soy products by HPLC and coulometric electrode array detection

被引:29
|
作者
Preinerstorfer, B [1 ]
Sontag, G [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
关键词
isoflavones; commercial soy products; high-performance liquid chromatography; coulometric electrode array detection;
D O I
10.1007/s00217-004-0955-9
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The concentrations of the isoflavones daidzein, genistein and glycitein were determined in a large number of commercially-available soy products by high-performance liquid chromatography with coulometric electrode array detection using estriol as internal standard. During extraction, the naturally occurring glycosides were converted into their respective aglycones by acid hydrolysis. The analytes were separated on a C-18 reversed phase column, eluted with methanol/acetonitrile/50 mM sodium acetate pH 4.8 (40/5/55, v/v/v), and detected by a coulometric electrode array detector using twelve electrodes set to potentials between +250 and +800 mV (in increments of 50 mV) against palladium reference electrodes. The isoflavones could be determined over a wide concentration range (0.8-1135.0 mg/kg for daidzein, 1.9-1442.5 mg/kg for genistein and 0.5-154.6 mg/kg for glycitein). The recovery of the isoflavones in the different matrices was determined by the standard addition method and varied between 40.9-94.4%. The detection limits (S/N=3) depend on the matrix of the soy product and were found for daidzein between 0.3-1.6 mg/kg, for genistein between 0.3-1.7 mg/kg and for glycitein between 0.5-2.3 mg/kg.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [31] Analysis of flavonoids in honey by HPLC coupled with coulometric electrode array detection and electrospray ionization mass spectrometry
    Karoline Petrus
    Heidi Schwartz
    Gerhard Sontag
    Analytical and Bioanalytical Chemistry, 2011, 400 : 2555 - 2563
  • [32] Coulometric array detection with HPLC for analysis of food adulteration.
    Acworth, IN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 21 - AGFD
  • [33] Simultaneous determination of isoflavones and bisphenol a in rat serum by high-performance liquid chromatography coupled with coulometric array detection
    Yasuda, S
    Wu, PS
    Hattori, E
    Tachibana, H
    Yamada, K
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2004, 68 (01) : 51 - 58
  • [34] Application of coulometric electrode array detection to the analysis of isoflavonoids and lignans
    Penalvo, Jose L.
    Nurmi, Tarja
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (05) : 1497 - 1507
  • [35] The coulometric electrode array for use in HPLC analysis .2. Applications overview
    Acworth, IN
    Waraska, J
    Gamache, PH
    AMERICAN LABORATORY, 1997, 29 (22) : I24 - +
  • [36] Determination of catechins and catechin gallates in biological fluids by HPLC with coulometric array detection and solid phase extraction
    Chu, KO
    Wang, CC
    Rogers, MS
    Choy, KW
    Pang, CP
    ANALYTICA CHIMICA ACTA, 2004, 510 (01) : 69 - 76
  • [37] Determination of Peak Purity in HPLC by Coupling Coulometric Array Detection and Two-Dimensional Correlation Analysis
    Oney-Montalvo, Julio Enrique
    Morozova, Ksenia
    Ramirez-Sucre, Manuel Octavio
    Scampicchio, Matteo
    Rodriguez-Buenfil, Ingrid Mayanin
    SENSORS, 2022, 22 (05)
  • [38] HPLC WITH ELECTRODE ARRAY DETECTION - DETERMINATION OF AMITROLE IN DRINKING AND GROUND-WATER
    BERNWIESER, I
    SONTAG, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (12): : 499 - 501
  • [39] The Application of HPLC with Coulometric Electrochemical Array Detection to the Study of Natural Products and Botanicals: From Targeted Analyses to Metabolomics
    Acworth, I. N.
    PLANTA MEDICA, 2011, 77 (12) : 1248 - 1248
  • [40] Sensitive analysis of phytoestrogens in animal tissue by HPLC with coulometric array detection
    Gamache, PH
    Maher, TJ
    Setchell, KDR
    Wu, TH
    Acworth, IN
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 68 (06): : 1536S - 1537S