Boron-Based Neutron Scintillator Screens for Neutron Imaging

被引:14
|
作者
Chuirazzi, William [1 ]
Craft, Aaron [1 ]
Schillinger, Burkhard [2 ,3 ]
Cool, Steven [4 ]
Tengattini, Alessandro [5 ,6 ]
机构
[1] Idaho Natl Lab, Adv Postirradiat Examinat Dept, Idaho Falls, ID 83401 USA
[2] Tech Univ Munich, Heinz Maier Leibnitz Zentrum FRM II, D-85748 Garching, Germany
[3] Tech Univ Munich, Heinz Maier Leibnitz Zentrum FRM II, Fac Phys E21, D-85748 Garching, Germany
[4] DMI Reading Imaging, Reading, MA 01867 USA
[5] Univ Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France
[6] Inst Laue Langevin ILL, 71 Ave Martyrs, F-38000 Grenoble, France
关键词
neutron imaging; neutron radiography; digital imaging; neutron scintillator; scintillator screen; boron scintillator; scintillator characterization; scintillator detection efficiency; epithermal neutron imaging; neutron sensor; FUEL-CELLS; THERMAL-NEUTRONS; NUCLEAR-FUEL; LIQUID WATER; FLOW-FIELD; RADIOGRAPHY; DETECTOR; PERFORMANCE; TOMOGRAPHY; OBJECTS;
D O I
10.3390/jimaging6110124
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on (LiF)-Li-6 and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because B-10 has a neutron absorption cross-section four times greater than Li-6, less energetic daughter products than Gd and Li-6, and lower gamma-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as Li-6-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common (LiF)-Li-6/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Fast-neutron imaging spectrometer based on liquid scintillator loaded capillaries
    Mor, I.
    Vartsky, D.
    Brandis, M.
    Goldberg, M. B.
    Bar, D.
    Mardor, I.
    Dangendorf, V.
    Bromberger, B.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [32] High-Resolution Thermal Neutron Imaging With 10Boron/CsI:Tl Scintillator Screen
    Miller, Stuart R.
    Marshall, Matthew S. J.
    Wart, Megan
    Crha, Jan
    Trtik, Pavel
    Nagarkar, Vivek V.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (08) : 1929 - 1933
  • [33] Simulation on spatial resolution of scintillator arrays based on neutron penumbral imaging system
    Yu, Bo
    Su, Ming
    Liu, Shenye
    Huang, Tianxuan
    Chen, Bolun
    Jiang, Wei
    Pu, Yudong
    Yan, Ji
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2012, 24 (08): : 1826 - 1830
  • [34] A FAST NEUTRON SCINTILLATOR
    EMMERICH, WS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (01): : 69 - 70
  • [35] Evaluation of boron-enriched plastic scintillator for thermal neutron detection
    Porosev, V. V.
    Savinov, G. A.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (06)
  • [36] Feasibility study of optical imaging of the boron-dose distribution by a liquid scintillator in a clinical boron neutron capture therapy field
    Maeda, Hideya
    Nohtomi, Akihiro
    Hu, Naonori
    Kakino, Ryo
    Akita, Kazuhiko
    Ono, Koji
    MEDICAL PHYSICS, 2024, 51 (01) : 509 - 521
  • [37] A fission neutron detector based on helium scintillator
    Zhang Xiao-Dong
    Qiu Meng-Tong
    Zhang Jian-Fu
    Ouyang Xiao-Ping
    Zhang Xian-Peng
    Chen Liang
    ACTA PHYSICA SINICA, 2012, 61 (23)
  • [38] Neutron measurement and inversion based on CLYC scintillator
    Hou, Donghui
    Zhang, Shenyi
    Yang, Yigang
    Wang, Qibiao
    Zhang, Binquan
    Yu, Qinglong
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2021, 47 (01): : 106 - 114
  • [39] Development of a Neutron Flux Monitor Using a Small Scintillator Coupled with Quartz Fiber for a Cyclotron-Based Boron Neutron Capture Therapy
    Tanaka, Hiroki
    Sakurai, Yoshinori
    Suzuki, Minoru
    Masunaga, Shinichiro
    Mitsumoto, Toshinori
    Kashino, Genro
    Kinashi, Yuko
    Liu, Yong
    Kawabata, Yuji
    Yagi, Takahiro
    Misawa, Tsuyoshi
    Ono, Koji
    Maruhashi, Akira
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 979 - +
  • [40] Neutron imaging and spatial resolution evaluation of the boron-lined honeycomb neutron converter based detector
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    Zhang, Zhi
    Wang, Xuewu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,