Clinical Outcomes of the Portico Transcatheter Aortic Valve Delivered via Alternative Access: 30-Day and 1-Year Results of the Portico ALT Study

被引:0
|
作者
van Wely, Marleen [1 ]
Bruschi, Giuseppe [2 ]
Bedogni, Francesco [3 ]
Thiele, Holger [4 ]
Jeger, Raban, V [5 ]
van der Wulp, Kees [1 ]
Soendergaard, Lars [6 ]
Kempfert, Joerg [7 ]
Schlensak, Christian [8 ]
Linke, Axel [9 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Nijmegen, Netherlands
[2] Osped Niguarda Ca Granda, Milan, Italy
[3] IRCCS Policlin San Donato Milan, Milan, Italy
[4] Univ Leipzig, Heart Ctr Leipzig, Leipzig, Germany
[5] Univ Basel, Cardiol Univ Hosp Basel, Basel, Switzerland
[6] Univ Copenhagen, Dept Cardiol, Rigshosp, Copenhagen, Denmark
[7] Deutsch Herzzentrum Berlin, Klin Herz Thorax & Gefaessghirurg, Berlin, Germany
[8] Univ Klinikum Fuebingen, Univ Klin Thorax Herz & Gefaesschirurg, Tubingen, Germany
[9] Tech Univ Dresden, Heart Ctr Dresden Dresden, Univ Klin Dept Internal Med & Cardiol, Dresden, Germany
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2020年 / 32卷 / 11期
关键词
aortic stenosis; axillary access; subclavian access; SUBCLAVIAN ACCESS; REPLACEMENT; IMPLANTATION; STENOSIS; RISK; DEFINITIONS; SAFETY; ARTERY; TAVI;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The aim of this study was to report the 30-day and 1-year outcomes and performance from the Portico Alternative Access study to obtain CE approval of the alternative access delivery system. Methods. The Portico Alternative Access study is a multicenter, prospective, non-randomized, investigational study (www.clinicaltrials.gov identifier, NCT03056573) describing 45 patients with severe symptomatic aortic valve stenosis [AS) treated with the self-expanding Portico device using subclavian/axillary access. Results. Forty-five subjects [81.7 +/- 5.9 years; 57.8% female; Society of Thoracic Surgeons score, 5.4 +/- 4.7%] with severe, symptomatic AS had a Portico bioprosthetic aortic valve implantation attempt via axillary/subclavian access. Implantation was successful in 97.8% of subjects. At 30 days. the rate of major vascular complications at the subclavian/axillary access site was 4.4%. All-cause mortality was 2.2% at 30 days and 4.4% at 1 year. Conclusion. The Portico transcatheter aortic valve can be safely delivered by axillary or subclavian access with high implant success rate and low complication rates.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [1] Early commercial experience from transcatheter aortic valve implantation using the Portico™ bioprosthetic valve: 30-day outcomes in the multicentre PORTICO-1 study
    Maisano, Francesco
    Worthley, Stephen
    Rodes-Cabau, Josep
    Linke, Axel Hans-Peter
    Fichtlscherer, Stephan
    Schaefer, Ulrich
    Makkar, Raj
    Fontana, Gregory
    Asch, Federico M.
    Sondergaard, Lars
    EUROINTERVENTION, 2018, 14 (08) : 886 - 893
  • [2] 30-Day Outcomes With the Portico Transcatheter Heart Valve: Insights From a Multi-Centre Australian Observational Study
    Camuglia, Anthony C.
    Cole, Christopher M. W.
    Boyne, Nicholas
    Hayman, Sam M.
    Cox, Stephen, V
    Moore, Peter T.
    Lau, Jerrett K.
    Delacroix, Sinny
    Williamson, Anna Emilie
    Duong, MyNgan
    Schwarz, Nisha
    Montarello, Joseph K.
    Worthley, Stephen G.
    HEART LUNG AND CIRCULATION, 2023, 32 (02): : 224 - 231
  • [3] 30-Day and 1-Year Outcomes With HYDRA Self-Expanding Transcatheter Aortic Valve The Hydra CE Study
    Aidietis, Audrius
    Srimahachota, Suphot
    Dabrowski, Maciej
    Bilkis, Vaildas
    Buddhari, Wacin
    Cheung, Gary S. H.
    Nair, Rajesh K.
    Mussayev, Abdurashid A.
    Mattummal, Shafeeq
    Chandra, Praveen
    Mahajan, Ajay U.
    Chmielak, Zbigniew
    Govindan, Sajeev C.
    Jose, John
    Hiremath, Murugesh S.
    Chandra, Sharad
    Shetty, Ranjan
    Mohanan, Sandeep
    John, John F.
    Mehrotra, Sanjay
    Sondergaard, Lars
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (01) : 93 - 104
  • [4] Transcatheter Aortic Valve Replacement With a Repositionable Self-Expanding Prosthesis The PORTICO-I Trial 1-Year Outcomes
    Sondergaard, Lars
    Rodes-Cabau, Josep
    Linke, Axel Hans-Peter
    Fichtlscherer, Stephan
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Kempfert, Joerg
    Arzamendi, Dabit
    Bedogni, Francesco
    Asch, Federico M.
    Worthley, Stephen
    Maisano, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (23) : 2859 - 2867
  • [5] The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes
    Helge Möllmann
    David M. Holzhey
    Michael Hilker
    Stefan Toggweiler
    Ulrich Schäfer
    Hendrik Treede
    Michael Joner
    Lars Søndergaard
    Thomas Christen
    Dominic J. Allocco
    Won-Keun Kim
    Clinical Research in Cardiology, 2021, 110 : 1912 - 1920
  • [6] The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes
    Moellmann, Helge
    Holzhey, David M.
    Hilker, Michael
    Toggweiler, Stefan
    Schaefer, Ulrich
    Treede, Hendrik
    Joner, Michael
    Sondergaard, Lars
    Christen, Thomas
    Allocco, Dominic J.
    Kim, Won-Keun
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (12) : 1912 - 1920
  • [7] Implantation and 30-Day Follow-Up on All 4 Valve Sizes Within the Portico Transcatheter Aortic Bioprosthetic Family
    Moellmann, Helge
    Linke, Axel
    Holzhey, David M.
    Walther, Thomas
    Manoharan, Ganesh
    Schaefer, Ulrich
    Heinz-Kuck, Karl
    Van Boven, Ad J.
    Redwood, Simon R.
    Kovac, Jan
    Butter, Christian
    Sondergaard, Lars
    Lauten, Alexander
    Schymik, Gerhard
    Worthley, Stephen G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (15) : 1538 - 1547
  • [8] Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: Results of the RELEVANT study
    Montone, Rocco A.
    Testa, Luca
    Fraccaro, Chiara
    Montorfano, Matteo
    Castriota, Fausto
    Nerla, Roberto
    Angelillis, Marco
    Tusa, Maurizio
    Giannini, Francesco
    Garatti, Andrea
    Tarantini, Giuseppe
    Petronio, Anna Sonia
    Brambilla, Nedy
    Bedogni, Francesco
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (07) : 1206 - 1211
  • [9] Feasibility and Durability of Percutaneous Aortic Valve Replacement: 30-day and 1-year Outcomes
    Maier, Robert
    Hoedl, Ronald
    Stoschitzky, Gergana
    Grabenwoeger, Martin
    Pollak, Johann
    Blazek, Stephan
    Paetzold, Dieter
    Watzinger, Norbert
    Pieske, Burkert
    Luha, Olev
    CIRCULATION, 2010, 122 (02) : E41 - E41
  • [10] Real-world procedural and 30-day outcome using the Portico transcatheter aortic valve prosthesis: A large single center cohort
    Denegri, Andrea
    Nietlispach, Fabian
    Kottwitz, Jan
    Suetsch, Gabor
    Haager, Philipp
    Rodriguez, Hector
    Taramasso, Maurizio
    Obeid, Slayman
    Maisano, Francesco
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 253 : 40 - 44