Voltage Reduction Technique for Use With Electrochemical Impedance Spectroscopy in High-Voltage Fuel Cell and Battery Systems

被引:17
|
作者
Homayouni, Hooman [1 ]
DeVaal, Jake [2 ]
Golnaraghi, Farid [1 ]
Wang, Jiacheng [1 ]
机构
[1] Simon Fraser Univ, Sch Mechatron Syst Engn, Surrey, BC V3T 0A3, Canada
[2] Ballard Power Syst, Burnaby, BC V5J 5J8, Canada
关键词
Battery; diagnostics; electrochemical impedance spectroscopy (EIS); fuel cell (FC); voltage reduction; ACTIVE COMPENSATION; MONITORING-SYSTEM; POWER CONVERTER; DIAGNOSIS; STACK; TECHNOLOGIES;
D O I
10.1109/TTE.2018.2806090
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An attractive application of electrochemical impedance spectroscopy (EIS) is for diagnostic of a fuel cell (FC) or a battery system during operation. The use of EIS, however, is mostly limited to low-voltage (LV) FC systems and laboratory environments. Hence, the application of EIS in advanced diagnostics of a high-power system certainly lacks due to the voltage limitation and/or cost of the equipment. In this paper, a precision, low-cost electronic interface is proposed which enables the use of existing LV ac diagnostic tools with a production-size FC or battery stacks without the need for postprocessing of data. The interface, a dc level reducer (DLR), reduces only the dc component of the stack voltage to a safe voltage of <60 without altering the ac diagnostic components. This paper explains in detail the development of the DLR circuitry. The scalability and real-world capability of the interface are demonstrated by developing it for two voltage ratings. A set of circuits rated for 30 V is tested with a nine-cell proton exchange membrane FC (PEMFC) stack, and circuits rated for 200 V are tested on 90- and 110-cell commercial PEMFC stacks. The stack voltage is reduced by 60% on the nine-cell stack, and 60%-90% on the 90- and 110-cell stacks. The accuracy is measured using EIS data for 74 frequency points in the range of 0.1-20 kHz, with and without the DLR. The maximum relative error for point-versus-point comparison of the impedance is measured at 0.8% and 1.4% for 30- and 200-V rated circuits, respectively. These errors are well within the error of the industrial measurement equipment used, proving the fidelity of the ac signal output from the DLR.
引用
收藏
页码:418 / 431
页数:14
相关论文
共 50 条
  • [31] TESTING OF HIGH-VOLTAGE COMPONENTS AND SYSTEMS
    ZWASS, S
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (05) : 937 - 937
  • [32] LOW-IMPEDANCE GENERATOR OF HIGH-VOLTAGE PULSES
    ANUFRIK, SS
    ZNOSKO, KF
    KURGANSKII, AD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (03) : 584 - 586
  • [33] MEASUREMENTS OF TRANSIENTS IN HIGH-VOLTAGE SYSTEMS
    PODGORSKI, AS
    PROCEEDINGS OF THE IEEE, 1986, 74 (01) : 108 - 110
  • [34] Method of noise reduction for high-voltage systems applied in subsea plants
    Kwon, Hyeok-Joon
    Yoon, Jae-Woo
    Cho, Hong
    Ryu, Seung-Jae
    Kim, Byeong-woo
    2013 INTERNATIONAL CONFERENCE ON IT CONVERGENCE AND SECURITY (ICITCS), 2013,
  • [35] High-Voltage, High-Impedance Ion Beam Production
    Hinshelwood, David
    Jackson, S. L.
    Allen, R. J.
    Commisso, R. J.
    Cooperstein, G.
    Mosher, D.
    Murphy, D. P.
    Ottinger, P. F.
    Schumer, J. W.
    Swanekamp, S. B.
    Weber, B. V.
    Young, F. C.
    2009 IEEE PULSED POWER CONFERENCE, VOLS 1 AND 2, 2009, : 227 - 232
  • [36] A LOW-IMPEDANCE HIGH-VOLTAGE NANOSECOND PULSER
    BAUER, G
    HEINRICH, H
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (06): : 688 - &
  • [37] The use of electrochemical impedance spectroscopy (EIS) in the evaluation of the electrochemical properties of a microbial fuel cell
    Manohar, Aswin K.
    Bretschger, Orianna
    Nealson, Kenneth H.
    Mansfeld, Florian
    BIOELECTROCHEMISTRY, 2008, 72 (02) : 149 - 154
  • [38] An Impedance Network Boost Converter With a High-Voltage Gain
    Zhang, Guidong
    Iu, Herbert Ho-Ching
    Zhang, Bo
    Li, Zhong
    Fernando, Tyrone
    Chen, Si-Zhe
    Zhang, Yun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 6661 - 6665
  • [39] High-voltage circuit-breaker technique
    不详
    NATURE, 1944, 153 : 627 - 627
  • [40] Carbonated Beverage Chemistry for High-Voltage Battery Cathodes
    Liao, Hengyi
    Cai, Mingzhi
    Ma, Wenqin
    Cao, Yuge
    Zhao, Siwei
    Dong, Yanhao
    Huang, Fuqiang
    ADVANCED MATERIALS, 2024, 36 (39)