N-D Point Cloud Registration for Intensity Normalization on Magnetic Resonance Images

被引:2
|
作者
Gao, Yuan [1 ,3 ]
Pan, Jiawei [2 ]
Guo, Yi [1 ,3 ]
Yu, Jinhua [1 ,3 ]
Zhang, Jun [2 ]
Geng, Daoying [2 ]
Wang, Yuanyuan [1 ,3 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai, Peoples R China
[2] Fudan Univ, Huashan Hosp, Dept Radiol, Shanghai, Peoples R China
[3] Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai, Peoples R China
来源
VIPIMAGE 2017 | 2018年 / 27卷
关键词
Magnetic resonance imaging; Intensity normalization; Sub-region intensity; Point cloud; Spline interpolation; HUMAN BRAIN; B-SPLINES; STANDARDIZATION; SCALE; ATLAS;
D O I
10.1007/978-3-319-68195-5_13
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Magnetic resonance imaging (MRI) is a non-invasive inspection method widely used in clinical environment. Therefore, this is one of the research hotspots in computer-aided medical diagnosis. However, due to the disparities in imaging protocols as well as the magnetic field strength, the variation of intensity in different MRI scanners results in performance reduction in automatic image analysis and diagnosis procedure. This paper aims at forming a non-rigid intensity transforming function to normalize the intensities of MRI images. The transforming function is obtained from an N-Dimensional (N-D) point cloud, which is formed of weighted sub-region intensity distribution. The proposed method consists of five parts, including pre-alignment, sub-region standard intensity estimation, weighted N-D point cloud generation, spline-based transforming function interpolation as well as final image normalization. This novel method could not only avoid the intensity distortion caused by inconsistent bright-dark relation between tissues in target images and reference images, but also reduce the dependence on the accuracy of multi-modality MRI image registration. The experiments were conducted on a database of 10 volunteers scanned with two different MRI scanners and three modalities. We show that the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) were both enhanced comparing with the histogram-matching method as well as the joint histogram registration method. It can be concluded that the intensities of MRI images acquired from different scanners could be normalized well using the proposed method so that multi-center/multi-machine correlation could be easily carried out in MRI image acquisition and analysis.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 50 条
  • [1] Longitudinal Intensity Normalization of Magnetic Resonance Images using Patches
    Roy, Snehashis
    Carass, Aaron
    Prince, Jerry L.
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [2] N-D Cloud Model
    Gou Jin
    Zhao ZhiQiang
    Chen WeiBin
    Luo Wei
    ISIP: 2009 INTERNATIONAL SYMPOSIUM ON INFORMATION PROCESSING, PROCEEDINGS, 2009, : 193 - +
  • [3] NUCLEAR MAGNETIC RESONANCE SPECTRA OF PYRROLE AND [N-D)PYRROLE
    KATEKAR, GF
    MORITZ, AG
    AUSTRALIAN JOURNAL OF CHEMISTRY, 1969, 22 (06) : 1199 - &
  • [4] 3D point cloud colorization by images registration
    Colorisation de nuages de points 3D par recalage dense d’images numériques
    1600, Lavoisier (31): : 1 - 2
  • [5] Simultaneous Registration and Intensity Normalization of SPECT Perfusion Images
    Silveira, Margarida
    Aguiar, Pedro M. Q.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5378 - 5381
  • [6] LIE GROUP FRAMEWORK OF ITERATIVE CLOSEST POINT ALGORITHM FOR n-D DATA REGISTRATION
    Ying, Shihui
    Peng, Jigen
    Du, Shaoyi
    Qiao, Hong
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2009, 23 (06) : 1201 - 1220
  • [7] Point Cloud Registration Using Intensity Features
    Lin, Chien-Chou
    Mao, Wei-Lung
    Hu, Ting-Lun
    SENSORS AND MATERIALS, 2020, 32 (07) : 2355 - 2364
  • [8] Nonlinear Registration of Brain Magnetic Resonance Images with Cross Constraints of Intensity and Structure
    Zhou, Han
    Xu, Hongtao
    Chang, Xinyue
    Zhang, Wei
    Dong, Heng
    CMC-COMPUTERS MATERIALS & CONTINUA, 2024, 79 (02): : 2295 - 2313
  • [9] NORMALIZATION OF N-D TAIL OF TRINUCLEON WAVE-FUNCTION
    LIM, TK
    PHYSICAL REVIEW LETTERS, 1973, 30 (15) : 709 - 710
  • [10] Robust Rigid Point Cloud Registration via RGB-D Images
    Zhong, Saishang
    Li, Yanlei
    Liu, Zheng
    Xie, Zhong
    Chen, Jianguo
    Wang, Weiming
    Liu, Xiuping
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics, 2022, 34 (01): : 25 - 35