Flow injection spectrophotometry of lead(II) by on-line preconcentration method using silica capillary tube

被引:0
|
作者
Watanabe, Kunihiro [1 ]
Ichihara, Fumitaka [1 ]
Itagaki, Masayuki [1 ]
机构
[1] Tokyo Univ Sci, Fac Sci & Technol, Dept Pure & Appl Chem, Noda, Chiba 2788510, Japan
关键词
on-line concentration; silica capillary tube; lead (II); TPPS; FIA;
D O I
10.2116/bunsekikagaku.55.579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel concentration on-line system for Pb(II) determination has been developed. The method is based on the adsorption of Pb(II) ions on the inner surface of a silica capillary tube (length, 25 m; i.d., 0.53 mm). The metal ions that were concentrated on a silica surface for 180 minutes were eluted on-line with a small amount of diluted nitric acid solution in a carrier line. The flow injection analysis system was composed of four channels, including the carrier, sample, buffer and detection reagent solution. The concentration efficiency of Pb(II), obtained by the present method, was about 910. The eluted Pb(II) ion was then determined with tetraphenylporphinetetrasulfonic acid (TPPS) by spectrophotometry. The calibration curve was linear at over the range of 0 to 2.5 ppb. The optimum conditions by the present method were as follows: pH of buffer solution for concentration, 9.5; TPPS, 5.0 x 10(-5) M, pH of TPPS solution, 12; concentration of eluent HNO3, 5.0 x 10(-3) M; volume of the eluent, 10 mu l; reaction coil length, 3.5 m; wave-length, 464 nm. The detection limits of Pb(II) was 0.004 ppb. The RSD of 1.5 ppb Pb(II) was 1.4% (n = 5). The present method was successfully applied to the determination of trace Pb(II) in river, swamp and tap water samples after masking Fe(III) and Cu(III) with triethanolamine.
引用
收藏
页码:579 / 585
页数:7
相关论文
共 50 条
  • [31] On-line preconcentration and determination of iron by flow injection analysis in nuclear fuels
    Chandramouleeswaran, S.
    Ramkumar, Jayshree
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (03) : 2073 - 2077
  • [32] On-line preconcentration and determination of lead and cadmium by sequential injection/anodic stripping voltammetry
    Ninwong, Benjawan
    Chuanuwatanakul, Suchada
    Chailapakul, Orawon
    Dungchai, Wijitar
    Motomizu, Shoji
    TALANTA, 2012, 96 : 75 - 81
  • [33] Determination of iodine in urine by flow injection catalytic spectrophotometry with on-line digestion
    Dan, DZ
    Li, P
    Li, RQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (04) : 486 - 490
  • [34] Flow-injection quantification of trace lead in water by on-line preconcentration-flame atomic absorption spectrometry
    Zhang, XY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (12) : 1493 - 1496
  • [35] Flow injection on-line minicolumn preconcentration and determination of trace copper ions using an alumina/titanium oxide grafted silica matrix and FAAS
    Lima, Giovana F.
    Ohara, Maikow O.
    Clausen, Debora N.
    Nascimento, Danielle R.
    Ribeiro, Emerson S.
    Segatelli, Mariana G.
    Bezerra, Marcos A.
    Tarley, Cesar R. T.
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 61 - 70
  • [36] An Automated Method of On-line Extraction Coupled with Flow Injection and Capillary Electrophoresis for Phytochemical Analysis
    Chen, Hongli
    Ding, Xiuping
    Wang, Min
    Chen, Xingguo
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (10) : 866 - 870
  • [37] Flow injection on-line minicolumn preconcentration and determination of trace copper ions using an alumina/titanium oxide grafted silica matrix and FAAS
    Giovana F. Lima
    Maikow O. Ohara
    Débora N. Clausen
    Danielle R. Nascimento
    Emerson S. Ribeiro
    Mariana G. Segatelli
    Marcos A. Bezerra
    César R. T. Tarley
    Microchimica Acta, 2012, 178 : 61 - 70
  • [38] On-line preconcentration and determination of trace metals using a flow injection system coupled to ion chromatography
    Bin Abas, MR
    Takruni, IA
    Abdullah, Z
    Tahir, NM
    TALANTA, 2002, 58 (05) : 883 - 890
  • [39] Determination of acetaminophen by flow injection with on-line chemical derivatization: Investigations using visible and FTIR spectrophotometry
    Ramos, ML
    Tyson, JF
    Curran, DJ
    ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) : 107 - 116
  • [40] Fluorometric determination of trace amounts of copper(II) using on-line adsorption preconcentration in Teflon capillary tubes
    Watanabe, K
    Ohba, K
    Iburaim, A
    Itagaki, M
    Koura, N
    BUNSEKI KAGAKU, 1998, 47 (03) : 179 - 185