Effects of mechanical and thermal aging on microleakage of different fissure sealants

被引:22
|
作者
Koyuturk, Alp Erdin [1 ]
Kusgoz, Adem [2 ]
Ulker, Mustafa [3 ]
Yesilyurt, Cemal [4 ]
机构
[1] Ondokuz Mayis Univ, Dept Pedodont, Fac Dent, TR-55139 Kurupelit, Samsun, Turkey
[2] Karadeniz Tech Univ, Fac Dent, Dept Pedodont, Trabzon, Turkey
[3] Erciyes Univ, Fac Dent, Dept Conservat Dent, Kayseri, Turkey
[4] Karadeniz Tech Univ, Fac Dent, Dept Conservat Dent, Trabzon, Turkey
关键词
Mechanical Loading; Thermal Cycling; Fissure Sealants;
D O I
10.4012/dmj.27.795
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to examine the microleakage of three different fissure sealants after they were aged by mechanical loading and thermocycling in vitro. To this end, a bonding agent (Prime & Bond (R) NT) and three different fissure sealants (Clinpro, Helioseal F, Teethmate F1) were used, whereby microleakage was evaluated using a dye penetration method after mechanical loading and/or thermocycling. Sealant-treated teeth were allocated into four groups: mechanical loading (50,000 times), thermocycling (10,000 times), mechanical loading (50,000 times) + thermocycling (10,000 times), and one control group. For each fissure sealant, both experimental and control groups showed statistically significant differences in average microleakage score (p<0.05). Further, for each fissure sealant, the highest average microleakage score was obtained in mechanical loading + thermocycling group. When comparison was done for each aging method, the average microleakage scores showed statistically significant differences among the three fissure sealants (P<0.05). Based on the results Of this study it was also concluded that, it is necessary to develop reliable in vitro test methods for dental materials.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 50 条
  • [31] Analysis of surface roughness and microleakage of fissure sealants following organic debris removal with Carisolv
    Yamada, Yoshishige
    Hossain, Mozammal
    Shimizu, Yuko
    Kimura, Yuichi
    Masuda, Yoshiko
    Nakamura, Yukio
    Matsumoto, Koukichi
    JOURNAL OF DENTISTRY, 2008, 36 (02) : 130 - 137
  • [32] An In-Vitro Analysis of Microleakage of Self-Adhesive Fissure Sealant vs. Conventional and GIC Fissure Sealants
    Gorseta, Kristina
    Borzabadi-Farahani, Ali
    Vrazic, Tara
    Glavina, Domagoj
    DENTISTRY JOURNAL, 2019, 7 (02)
  • [33] In vitro evaluation of wear resistance, microhardness and superficial roughness of different fissure sealants after aging
    Akcay, Hulya Cerci
    Aktoren, Oya
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2024, 48 (01) : 32 - 40
  • [34] Microleakage of sealants placed with different enamel conditioners.
    Summers, AW
    Latta, MA
    Ellis, RW
    Barkmeier, WW
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 130 - 130
  • [36] THE EFFECTS OF PIT AND FISSURE SEALANTS ON MASTICATORY FUNCTION
    WARD, G
    MANSON, I
    JOURNAL OF DENTAL RESEARCH, 1982, 61 (04) : 611 - 611
  • [37] EFFECTS OF MOISTURE ON RETENTION OF FISSURE SEALANTS INVITRO
    YOUNG, KC
    HUSSEY, M
    STEPHEN, KW
    CARIES RESEARCH, 1975, 9 (04) : 313 - 314
  • [38] Microleakage and SEM evaluation of fissure sealants placed by use of self-etching priming agents
    Hannig, M
    Gräfe, A
    Atalay, S
    Bott, B
    JOURNAL OF DENTISTRY, 2004, 32 (01) : 75 - 81
  • [39] EFFECT OF DIFFERENT FISSURE SEALANTS AFTER ONE YEAR
    STADTLER, P
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1984, 39 (01): : 43 - 45
  • [40] Effect of bevelling on marginal microleakage of buccal-surface fissure sealants in permanent teeth.
    Mazhari F.
    Mehrabkhani M.
    Sadeghi S.
    Malekabadi K.S.
    European Archives of Paediatric Dentistry, 2009, 10 (4) : 241 - 243