CineECG: A novel method to image the average activation sequence in the heart from the 12-lead ECG

被引:7
|
作者
Boonstra, Machteld J. [1 ]
Brooks, Dana H. [2 ]
Loh, Peter [1 ]
van Dam, Peter M. [1 ,3 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Cardiol, Div Heart & Lungs, Utrecht, Netherlands
[2] Northeastern Univ, Elect & Comp Engn, Boston, MA 02115 USA
[3] ECG Excellence BV, Nieuwerbrug Aan Den Rijn, Netherlands
关键词
Electrocardiogram; Vectorcardiogram; Cardiac modeling; Average activation sequence; Cardiac isochrones; CineECG; ECG imaging; Inverse ECG; OF-CARDIOLOGY-FOUNDATION; PREMATURE VENTRICULAR CONTRACTIONS; ASSOCIATION ELECTROCARDIOGRAPHY; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; CLINICAL CARDIOLOGY; AHA/ACCF/HRS RECOMMENDATIONS; VARIABILITY; STANDARDIZATION; LOCALIZATION;
D O I
10.1016/j.compbiomed.2021.105128
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The standard 12-lead electrocardiogram (ECG) is a diagnostic tool to asses cardiac electrical activity. The vectorcardiogram is a related tool that represents that activity as the direction of a vector. In this work we investigate CineECG, a new 12-lead ECG based analysis method designed to directly estimate the average cardiac anatomical location of activation over time. We describe CineECG calculation and a novel comparison parameter, the average isochrone position (AIP). In a model study, fourteen different activation sequences were simulated and corresponding 12-lead ECGs were computed. The CineECG was compared to AIP in terms of location and direction. In addition, 67-lead body surface potential maps from ten patients were used to study the sensitivity of CineECG to electrode mispositioning and anatomical model selection. Epicardial activation maps from four patients were used for further evaluation. The average distance between CineECG and AIP across the fourteen sequences was 23.7 +/- 2.4 mm, with significantly better agreement in the terminal (27.3 +/- 5.7 mm) versus the initial QRS segment (34.2 +/- 6.1 mm). Up to four cm variation in electrode positioning produced an average distance of 6.5 +/- 4.5 mm between CineECG trajectories, while substituting a generic heart/torso model for a patient-specific one produced an average difference of 6.1 +/- 4.8 mm. Dominant epicardial activation map features were recovered. Qualitatively, CineECG captured significant features of activation sequences and was robust to electrode misplacement. CineECG provides a realistic representation of the average cardiac activation in normal and diseased hearts. In particular, the terminal segment of the CineECG might be useful to detect pathology.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] CLINICAL VALIDATION OF A NOVEL, SMARTPHONE-BASED 12-LEAD ECG DEVICE
    Stavrakis, Stavros
    Whyte, Seabrook
    Sample, Karlie
    Barber, Rylee
    Albert, David
    Po, Sunny S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 2034 - 2034
  • [22] FROM PAIN TO REPERFUSION - WHAT ROLE FOR THE PREHOSPITAL 12-LEAD ECG
    CUMMINS, RO
    EISENBERG, MS
    ANNALS OF EMERGENCY MEDICINE, 1990, 19 (11) : 1343 - 1346
  • [23] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG (vol 20, pg 405, 2019)
    Wang, Lu-di
    Zhou, Wei
    Xing, Ying
    Liu, Na
    Movahedipour, Mahmood
    Zhou, Xiao-guang
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (05) : 750 - 750
  • [24] Preprocessing Method for Performance Enhancement in CNN-Based STEMI Detection From 12-Lead ECG
    Park, Yeonghyeon
    Yun, Il Dong
    Kang, Si-Hyuck
    IEEE ACCESS, 2019, 7 : 99964 - 99977
  • [25] Learning cardiac activation maps from 12-lead ECG with multi-fidelity Bayesian optimization on manifolds
    Pezzuto, Simone
    Perdikaris, Paris
    Costabal, Francisco Sahli
    IFAC PAPERSONLINE, 2022, 55 (20): : 175 - 180
  • [26] A Novel Single Lead to 12-Lead ECG Reconstruction Methodology Using Convolutional Neural Networks and LSTM
    Gundlapalle, Vishnuvardhan
    Acharyya, Amit
    2022 IEEE 13TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS AND SYSTEMS (LASCAS), 2022, : 124 - 127
  • [27] A novel lightweight computerized ECG interpretation approach based on clinical 12-lead data
    YunQing Liu
    ChengJin Qin
    JinLei Liu
    YanRui Jin
    ZhiYuan Li
    LiQun Zhao
    ChengLiang Liu
    Science China Technological Sciences, 2024, 67 : 449 - 463
  • [28] A Novel Approach to a Regionalized Multidisciplinary Multi-Institutional Transmission of 12-Lead ECG
    Wampler, David A.
    Trifilio, Frankie
    Baker, Cheryl
    Epley, Eric
    Wait, Dudley
    Alvarez, Jorge
    CIRCULATION, 2018, 138
  • [29] A novel lightweight computerized ECG interpretation approach based on clinical 12-lead data
    Liu, Yunqing
    Qin, Chengjin
    Liu, Jinlei
    Jin, Yanrui
    Li, Zhiyuan
    Zhao, Liqun
    Liu, Chengliang
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2024, 67 (02) : 449 - 463
  • [30] A novel lightweight computerized ECG interpretation approach based on clinical 12-lead data
    LIU YunQing
    QIN ChengJin
    LIU JinLei
    JIN YanRui
    LI ZhiYuan
    ZHAO LiQun
    LIU ChengLiang
    Science China Technological Sciences, 2024, 67 (02) : 449 - 463