CineECG: A novel method to image the average activation sequence in the heart from the 12-lead ECG

被引:7
|
作者
Boonstra, Machteld J. [1 ]
Brooks, Dana H. [2 ]
Loh, Peter [1 ]
van Dam, Peter M. [1 ,3 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Cardiol, Div Heart & Lungs, Utrecht, Netherlands
[2] Northeastern Univ, Elect & Comp Engn, Boston, MA 02115 USA
[3] ECG Excellence BV, Nieuwerbrug Aan Den Rijn, Netherlands
关键词
Electrocardiogram; Vectorcardiogram; Cardiac modeling; Average activation sequence; Cardiac isochrones; CineECG; ECG imaging; Inverse ECG; OF-CARDIOLOGY-FOUNDATION; PREMATURE VENTRICULAR CONTRACTIONS; ASSOCIATION ELECTROCARDIOGRAPHY; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; CLINICAL CARDIOLOGY; AHA/ACCF/HRS RECOMMENDATIONS; VARIABILITY; STANDARDIZATION; LOCALIZATION;
D O I
10.1016/j.compbiomed.2021.105128
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The standard 12-lead electrocardiogram (ECG) is a diagnostic tool to asses cardiac electrical activity. The vectorcardiogram is a related tool that represents that activity as the direction of a vector. In this work we investigate CineECG, a new 12-lead ECG based analysis method designed to directly estimate the average cardiac anatomical location of activation over time. We describe CineECG calculation and a novel comparison parameter, the average isochrone position (AIP). In a model study, fourteen different activation sequences were simulated and corresponding 12-lead ECGs were computed. The CineECG was compared to AIP in terms of location and direction. In addition, 67-lead body surface potential maps from ten patients were used to study the sensitivity of CineECG to electrode mispositioning and anatomical model selection. Epicardial activation maps from four patients were used for further evaluation. The average distance between CineECG and AIP across the fourteen sequences was 23.7 +/- 2.4 mm, with significantly better agreement in the terminal (27.3 +/- 5.7 mm) versus the initial QRS segment (34.2 +/- 6.1 mm). Up to four cm variation in electrode positioning produced an average distance of 6.5 +/- 4.5 mm between CineECG trajectories, while substituting a generic heart/torso model for a patient-specific one produced an average difference of 6.1 +/- 4.8 mm. Dominant epicardial activation map features were recovered. Qualitatively, CineECG captured significant features of activation sequences and was robust to electrode misplacement. CineECG provides a realistic representation of the average cardiac activation in normal and diseased hearts. In particular, the terminal segment of the CineECG might be useful to detect pathology.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Novel CineECG Derived From Standard 12-Lead ECG Enables Right Ventricle Outflow Tract Localization of Electrical Substrate in Patients With Brugada Syndrome
    van Dam, Peter M.
    Locati, Emanuela T.
    Ciconte, Giuseppe
    Borrelli, Valeria
    Heilbron, Francesca
    Santinelli, Vincenzo
    Vicedomini, Gabriele
    Monasky, Michelle M.
    Micaglio, Emanuele
    Giannelli, Luigi
    Mecarocci, Valerio
    Calovic, Zarko
    Anastasia, Luigi
    Pappone, Carlo
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (09): : E008524
  • [2] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Wang, Lu-di
    Zhou, Wei
    Xing, Ying
    Liu, Na
    Movahedipour, Mahmood
    Zhou, Xiao-guang
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (03) : 405 - 413
  • [3] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di WANG
    Wei ZHOU
    Ying XING
    Na LIU
    Mahmood MOVAHEDIPOUR
    Xiao-guang ZHOU
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 (03) : 405 - 413
  • [4] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 405 - 413
  • [5] Validation of the 3-lead tele-ECG versus the 12-lead tele-ECG and the conventional 12-lead ECG method in older people
    Antonicelli, Roberto
    Ripa, Chiara
    Abbatecola, Angela M.
    Capparuccia, Carlo A.
    Ferrara, Letizia
    Spazzafumo, Liana
    JOURNAL OF TELEMEDICINE AND TELECARE, 2012, 18 (02) : 104 - 108
  • [6] Image based deep learning in 12-lead ECG diagnosis
    Ao, Raymond
    He, George
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2023, 5
  • [7] Estimation of Regional Electrical Properties of the Heart from 12-Lead ECG and Images
    Seegerer, Philipp
    Mansi, Tommaso
    Jolly, Marie-Pierre
    Neumann, Dominik
    Georgescu, Bogdan
    Kamen, Ali
    Kayvanpour, Elham
    Amr, Ali
    Sedaghat-Hamedani, Farbod
    Haas, Jan
    Katus, Hugo
    Meder, Benjamin
    Comaniciu, Dorin
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: IMAGING AND MODELLING CHALLENGES, 2015, 8896 : 204 - 212
  • [8] Erratum to: A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 750 - 750
  • [9] A novel mobile transtelephonic system with synthesized 12-lead ECG
    Hadzievski, L
    Bojovic, B
    Vukcevic, V
    Belicev, P
    Pavlovic, S
    Vasiljevic-Pokrajcic, Z
    Ostojic, M
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (04): : 428 - 438
  • [10] Novel non-invasive ECG imaging method based on the 12-lead ECG for reconstruction of ventricular activation: A proof-of-concept study
    Fruelund, Patricia Zerlang
    Van Dam, Peter M.
    Melgaard, Jacob
    Sommer, Anders
    Lundbye-Christensen, Soren
    Sogaard, Peter
    Zaremba, Tomas
    Graff, Claus
    Riahi, Sam
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10