A Reliability of Active and Passive Knee Joint Position Sense Assessment Using the Luna EMG Rehabilitation Robot

被引:6
|
作者
Oleksy, Lukasz [1 ,2 ]
Krolikowska, Aleksandra [3 ]
Mika, Anna [4 ]
Reichert, Pawel [5 ]
Kentel, Monika [6 ]
Kentel, Maciej [6 ]
Poswiata, Anna [7 ]
Roksela, Anna [8 ]
Kozak, Dominika [7 ]
Bienias, Katarzyna [7 ]
Smolinski, Marcel [8 ]
Stolarczyk, Artur [9 ]
Mikulski, Michal [7 ]
机构
[1] Jagiellonian Univ Med Coll Krakow, Fac Hlth Sci, Dept Physiotherapy, PL-31008 Krakow, Poland
[2] Oleksy Med & Sport Sci, PL-37100 Lancut, Poland
[3] Wroclaw Med Univ, Fac Hlth Sci, Dept Physiotherapy, Ergon & Biomed Monitoring Lab, PL-50368 Wroclaw, Poland
[4] Univ Phys Educ Krakow, Inst Clin Rehabil, PL-31571 Krakow, Poland
[5] Wroclaw Med Univ, Fac Med, Dept Trauma Surg, Clin Dept Trauma & Hand Surg, PL-50368 Wroclaw, Poland
[6] eMKaMED Med Ctr, PL-53110 Wroclaw, Poland
[7] EGZOTech Sp Zoo, PL-44100 Gliwice, Poland
[8] Silesian Tech Univ, Fac Automatic Control Elect & Comp Sci, PL-44100 Gliwice, Poland
[9] Med Univ Warsaw, Med Fac, Dept Orthopaed & Rehabil, PL-02091 Warsaw, Poland
关键词
biomedical monitoring; joint position sense; knee; patient monitoring; physiotherapy; proprioception; rehabilitation robotics; reliability; symmetry; LOWER-LIMB JOINTS; PHYSICAL-ACTIVITY; PROPRIOCEPTION; AGE; REPRODUCTION; DYNAMOMETER; GONIOMETER; VALIDITY; TORQUE; TRIALS;
D O I
10.3390/ijerph192315885
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Joint position sense (JPS) is the awareness of joint location in space, indicating accuracy and precision of the movement. Therefore, the aim of the present study is to determine the reliability of active and passive JPS assessment regarding the knee joint. This was carried out using the Luna EMG rehabilitation robot. Further analysis assessed whether the examination of only the dominant site is justified and if there are differences between sites. The study comprised 24 healthy male participants aged 24.13 +/- 2.82 years, performing sports at a recreational level. Using the Luna EMG rehabilitation robot, JPS tests were performed for the right and left knees during flexion and extension in active and passive mode, in two separate sessions with a 1-week interval. Both knee flexion and extension in active and passive modes demonstrated high reliability (ICC = 0.866-0.982; SEM = 0.63-0.31). The mean JPS angle error did not differ significantly between the right and left lower limbs (p < 0.05); however, no between-limb correlation was noted (r = 0.21-0.34; p > 0.05). The Bland-Altman plots showed that the between-limb bias was minimal, with relatively wide limits of agreement. Therefore, it was concluded that the Luna EMG rehabilitation robot is a reliable tool for active and passive knee JPS assessment. In our study, JPS angle error did not differ significantly between left and right sides; however, the slight asymmetry was observed (visible in broad level of agreement exceeding 5 degrees in Bland-Altman plots), what may suggest that in healthy subjects, e.g., active athletes, proprioception should always be assessed on both sides.