A Reliability of Active and Passive Knee Joint Position Sense Assessment Using the Luna EMG Rehabilitation Robot

被引:6
|
作者
Oleksy, Lukasz [1 ,2 ]
Krolikowska, Aleksandra [3 ]
Mika, Anna [4 ]
Reichert, Pawel [5 ]
Kentel, Monika [6 ]
Kentel, Maciej [6 ]
Poswiata, Anna [7 ]
Roksela, Anna [8 ]
Kozak, Dominika [7 ]
Bienias, Katarzyna [7 ]
Smolinski, Marcel [8 ]
Stolarczyk, Artur [9 ]
Mikulski, Michal [7 ]
机构
[1] Jagiellonian Univ Med Coll Krakow, Fac Hlth Sci, Dept Physiotherapy, PL-31008 Krakow, Poland
[2] Oleksy Med & Sport Sci, PL-37100 Lancut, Poland
[3] Wroclaw Med Univ, Fac Hlth Sci, Dept Physiotherapy, Ergon & Biomed Monitoring Lab, PL-50368 Wroclaw, Poland
[4] Univ Phys Educ Krakow, Inst Clin Rehabil, PL-31571 Krakow, Poland
[5] Wroclaw Med Univ, Fac Med, Dept Trauma Surg, Clin Dept Trauma & Hand Surg, PL-50368 Wroclaw, Poland
[6] eMKaMED Med Ctr, PL-53110 Wroclaw, Poland
[7] EGZOTech Sp Zoo, PL-44100 Gliwice, Poland
[8] Silesian Tech Univ, Fac Automatic Control Elect & Comp Sci, PL-44100 Gliwice, Poland
[9] Med Univ Warsaw, Med Fac, Dept Orthopaed & Rehabil, PL-02091 Warsaw, Poland
关键词
biomedical monitoring; joint position sense; knee; patient monitoring; physiotherapy; proprioception; rehabilitation robotics; reliability; symmetry; LOWER-LIMB JOINTS; PHYSICAL-ACTIVITY; PROPRIOCEPTION; AGE; REPRODUCTION; DYNAMOMETER; GONIOMETER; VALIDITY; TORQUE; TRIALS;
D O I
10.3390/ijerph192315885
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Joint position sense (JPS) is the awareness of joint location in space, indicating accuracy and precision of the movement. Therefore, the aim of the present study is to determine the reliability of active and passive JPS assessment regarding the knee joint. This was carried out using the Luna EMG rehabilitation robot. Further analysis assessed whether the examination of only the dominant site is justified and if there are differences between sites. The study comprised 24 healthy male participants aged 24.13 +/- 2.82 years, performing sports at a recreational level. Using the Luna EMG rehabilitation robot, JPS tests were performed for the right and left knees during flexion and extension in active and passive mode, in two separate sessions with a 1-week interval. Both knee flexion and extension in active and passive modes demonstrated high reliability (ICC = 0.866-0.982; SEM = 0.63-0.31). The mean JPS angle error did not differ significantly between the right and left lower limbs (p < 0.05); however, no between-limb correlation was noted (r = 0.21-0.34; p > 0.05). The Bland-Altman plots showed that the between-limb bias was minimal, with relatively wide limits of agreement. Therefore, it was concluded that the Luna EMG rehabilitation robot is a reliable tool for active and passive knee JPS assessment. In our study, JPS angle error did not differ significantly between left and right sides; however, the slight asymmetry was observed (visible in broad level of agreement exceeding 5 degrees in Bland-Altman plots), what may suggest that in healthy subjects, e.g., active athletes, proprioception should always be assessed on both sides.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Reliability of Passive Knee Joint Position Sense Test
    Kim, Se-Hwan
    Seo, Kyung-Mook
    Kim, Don-Kyu
    Kang, Si-Hyun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2010, 34 (05): : 560 - 564
  • [2] A systematic review to determine the reliability of knee joint position sense assessment measures
    Smith, Toby O.
    Davies, Leigh
    Hing, Caroline B.
    KNEE, 2013, 20 (03): : 162 - 169
  • [3] Reliability of the active knee joint position sense test and influence of limb dominance and sex
    Busch, Aglaja
    Bangerter, Christian
    Mayer, Frank
    Baur, Heiner
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Reliability of the active knee joint position sense test and influence of limb dominance and sex
    Aglaja Busch
    Christian Bangerter
    Frank Mayer
    Heiner Baur
    Scientific Reports, 13
  • [5] Joint position sense and rehabilitation in the anterior cruciate ligament deficient knee
    Carter, ND
    Jenkinson, TR
    Wilson, D
    Jones, DW
    Torode, AS
    BRITISH JOURNAL OF SPORTS MEDICINE, 1997, 31 (03) : 209 - 212
  • [6] The role of weightbearing in the clinical assessment of knee joint position sense
    Stillman, BC
    McMeeken, JM
    AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 2001, 47 (04): : 247 - 253
  • [7] ASSESSMENT OF KNEE JOINT POSITION SENSE IN PATIENTS WITH MULTIPLE SCLEROSIS
    Tsvetkova-Gaberska, Miglena
    Pencheva, Nevena
    JOURNAL OF IMAB, 2021, 27 (03): : 3893 - 3900
  • [8] Reliability of joint position sense measured in the knee using the level function of the iPhone "Measure" application
    Nakashima, Yuki
    Iwaki, Daisuke
    Kawae, Toshihiro
    Fudeyasu, Kenichi
    Kimura, Hiroaki
    PLOS ONE, 2021, 16 (08):
  • [9] Evaluation of Reliability of the Luna EMG Rehabilitation Robot to Assess Proprioception in the Upper Limbs in 102 Healthy Young Adults
    Leszczak, Justyna
    Wolan-Nieroda, Andzelina
    Druzbicki, Mariusz
    Poswiata, Anna
    Mikulski, Michal
    Roksela, Anna
    Guzik, Agnieszka
    MEDICAL SCIENCE MONITOR, 2024, 30
  • [10] Assessment of joint position sense in active and passive modes with various elbow flexion angles and movement speeds using an isokinetic dynamometer
    Tsai, Yi-Jung
    Tsai, Ting-Chien
    Chung, Tzu-Chun
    Hsiao, Chih-Kun
    Tu, Yuan-Kun
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 73