Assistive Smart Sensing Devices for Gait Rehabilitation Monitoring

被引:2
|
作者
Postolache, O. [1 ]
Pereira, J. M. D. [3 ]
Ribeiro, M. [2 ]
Girao, P. [2 ]
机构
[1] Inst Telecomunicacoes ISCTE IUL, Lisbon, Portugal
[2] Inst Telecomunicacoes DEEC IST UL, Lisbon, Portugal
[3] Inst Telecomunicacoes ESTSetubal IPS, LabIM, Setubal, Portugal
关键词
Microwave Doppler radar; Inertial measurement system; Gait monitoring; Time frequency analysis;
D O I
10.1007/978-3-662-48645-0_20
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Smart sensing devices are nowadays part of the ambient assisted living architectures and may be adapted and personalized for gait rehabilitation assessment. Aiming an objective evaluation of patient progress during the physiotherapy sessions, the design and implementation of a set of sensing devices were carried out. Thus, it was considered a wearable solution materialized by a smart inertial measurement unit (IMU) and/or a set of walking aid objects characterized by embedded unobtrusive sensing units based on microwave Doppler radars. The data delivered by the smart sensing units designed for gait rehabilitation purpose are wireless transmitted to an advanced processing server that provides synthetic information to the physiotherapist that use a mobile device to access the available services. Elements of IMU sensor network and smart rollator design and implementation for gait assessment, as well as sensor signals digital processing, are included in the chapter.
引用
收藏
页码:234 / 247
页数:14
相关论文
共 50 条
  • [41] An Assistive VLC Technology for Smart Home Devices Using EOG
    Durai Rajan Dhatchayeny
    Willy Anugrah Cahyadi
    Yeon-Ho Chung
    Wireless Personal Communications, 2018, 98 : 81 - 89
  • [42] Design and Evaluation of the AIRGAIT Exoskeleton: Leg Orthosis Control for Assistive Gait Rehabilitation
    Dzahir, Mohd Azuwan Mat
    Yamamoto, Shin-Ichiroh
    JOURNAL OF ROBOTICS, 2013, 2013
  • [43] Modified Elliptical Machine Motor-Drive Design for Assistive Gait Rehabilitation
    Nelson, Carl A.
    Burnfield, Judith M.
    Shu, Yu
    Buster, Thad W.
    Taylor, Adam P.
    Graham, Andrew
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (02):
  • [44] Review and Classification of Human Gait Training and Rehabilitation Devices
    Martins, Maria
    Frizera, Anselmo
    Santos, Cristina P.
    Ceres, Ramon
    EVERYDAY TECHNOLOGY FOR INDEPENDENCE AND CARE, 2011, 29 : 774 - 781
  • [45] A review in gait rehabilitation devices and applied control techniques
    Chaparro-Cardenas, Silvia L.
    Lozano-Guzman, Alejandro A.
    Andres Ramirez-Bautista, Julian
    Hernandez-Zavala, Antonio
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2018, 13 (08) : 819 - 834
  • [46] Smart Sensing Devices for Logistics Application
    Masoudinejad, Mojtaba
    Venkatapathy, Aswin Karthik Ramachandran
    Emmerich, Jan
    Riesner, Andreas
    SENSOR SYSTEMS AND SOFTWARE, 2017, 205 : 41 - 52
  • [47] Smart Monitoring System for Stroke Rehabilitation
    Al Atallah, Mais
    Jamil, Zainab
    Khafagy, Hania
    Ummar, Mehnaz
    Aloul, Fadi
    Sagahyroon, Assim
    2021 IEEE INTERNATIONAL CONFERENCE ON INTERNET OF THINGS AND INTELLIGENCE SYSTEMS (IOTAIS), 2021, : 42 - 48
  • [48] Smart Rehabilitation Garment for Posture Monitoring
    Wang, Q.
    Chen, W.
    Timmermans, A. A. A.
    Karachristos, C.
    Martens, J. B.
    Markopoulos, P.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5736 - 5739
  • [49] Smart and Assistive Walker - ASBGo: Rehabilitation Robotics: A Smart-Walker to Assist Ataxic Patients
    Moreira, Rui
    Alves, Joana
    Matias, Ana
    Santos, Cristina
    ROBOTICS IN HEALTHCARE: FIELD EXAMPLES AND CHALLENGES, 2019, 1170 : 37 - 68
  • [50] Research on Monitoring Assistive Devices for Rehabilitation of Movement Disorders through Multi-Sensor Analysis Combined with Deep Learning
    Xu, Zhenyu
    Wu, Zijing
    Wang, Linlin
    Ma, Ziyue
    Deng, Juan
    Sha, Hong
    Wang, Hong
    SENSORS, 2024, 24 (13)